A simple, rapid and sensitive method for the analysis of Atenolol in pure and pharmaceutical preparation as an alternative analytical procedure were developed by continuous flow injection analysis via turbidimetric (T180o) and scattered light effect at two opposite position (2N90o). The method is based upon the formation of white precipitate for the ion pair compound by phosphomolybidic acid with Atenolol in aqueous medium. The precipitate is measured via the attenuation of incident light and scattering of the incident light in two opposite direction namely +90o and -90o angle were measured. Chemical and physical parameters were investigated. The linearity of Atenolol is ranged from (0.1-11) mmol.L-1, with correlation coefficient r=0.9938, lower limit of detection (LOD) 0.05 mmol.L-1(3SB)(S/N=3) for n=13 and the relative standard deviation for 7 mmol.L-1 Atenolol solution is lower than 3% (n=7). The method was applied successfully for the determination of atenolol in three pharmaceutical drugs. A comparisons were made between the newly developed method of analysis with the classical method ( uv-spectrophotometry at wave length 274nm) of analysis using the standard addition method via the use of t- test. It shows that there was no significant difference at α=0.05(95% confidence) between the two methods. Therefore the newly developed method can be accepted as an alternative method for the analysis of Atenolol, in addition to comparison between the official value and the calculated value for both methods
This paper proposes a new algorithm (F2SE) and algorithm (Alg(n – 1)) for solving the
two-machine flow shop problem with the objective of minimizing total earliness. This
complexity result leads us to use an enumeration solution approach for the algorithm (F2SE)
and (DM) is more effective than algorithm Alg( n – 1) to obtain approximate solution.
A simple, rapid and sensitive spectrophotometirc method for the determination of trace amounts of promethazine hydrochloride in the aqueous solution is described. The method is based on the complexation of promethazine hydrochloride with In (III) in the presence of sodium hydroxide to form an soluble product with maximum absorption at 304nm. Beer’s law is obeyed over the concentration range of (2- 20μg/ml) with molar absorptivity of (1.92× 103 L.mol-1 .cm -1 ). The optimum conditions for all development are described and the proposed method has been successfully applied for the determination of promethazine hydrochloride in bulk drug.
This study was carried out on 10 adult females of albino mice , aged 8 – 10 weeks and 24 – 27 gm weight . In addition to 10 males were used for mating in order to determine the effect of injection of bromocriptine on the early stages of pregnancy and this was observed by measuring the weights of some component of female reproduction . The animals were divided into groups
... Show MoreThe Arabic grammatical theory is characterized by the characteristics that distinguish it from other languages. It is based on the following equation: In its entirety a homogeneous linguistic system that blends with the social nature of the Arab, his beliefs, and his culture.
This means that this theory was born naturally, after the labor of maintaining an integrated inheritance, starting with its legal text (the Koran), and ends with its features of multiple attributes.
Saber was carrying the founding crucible of that theory, which takes over from his teacher, Hebron, to be built on what it has reached. It is redundant to point to his location and the status of his book.
So came to my research tagged: (c
The effect of White Place Image ( Test Image ) A4 has been studied as a function of luminous intensity using the t tu un ng gs st te en n l la am mpp and web camera enet. It was found that the tungsten lamp gives almost even intensities for the three color band and lighting composite at low voltage .while at high voltage causes a fare from each other . The statistical characteristic(mean and stander deviation ) results for three colors composites RGB and lighting composites L showed that the mean and stander deviation increases with the increase of voltage possibly owing to the increase image resolution, which reflects the value of stander deviation for the blue band
... Show MoreCharge transfer complex formation method has been applied for the spectrophotometric determination of erythromycin ethylsuccinate, in bulk sample and dosage form. The method was accurate, simple, rapid, inexpensive and sensitive depending on the formed charge- transfer complex between cited drug and, 2,3- Dichloro-5,6-dicyano-p- benzoquinone (DDQ) as a chromogenic reagent. The formed complex shows absorbance maxima at 587 nm against reagent blank. The calibration graph is linear in the ranges of (10 - 110) μg.mL-1 with detection limit of 0.351μg.mL-1. The results show the absence of interferences from the excipients on the determination of the drug. Therefore the proposed method has been successfully applied for the determination of eryth
... Show MoreThe flow measurements have increased importance in the last decades due to the shortage of water resources resulting from climate changes that request high control of the available water needed for different uses. The classical technique of open channel flow measurement by the integrating-float method was needed for measuring flow in different locations when there were no available modern devices for different reasons, such as the cost of devices. So, the use of classical techniques was taken place to solve the problem. The present study examines the integrating float method and defines the parameters affecting the acceleration of floating spheres in flowing water that was analyzed using experimental measurements. The me
... Show More