Preferred Language
Articles
/
ijs-11541
New Approach for the On-Line Spectrophotometric Determination of Folic Acid in Pure and Pharmaceutical Preparation via Oxidation by Cerium(IV) Sulphate Using Ayah 3Sx3-3D-Solar Cell CFI Spectrophotometer Analyzer
...Show More Authors

A newly photometric analytical method characterized by its speed and sensitivity was developed for the determination of folic acid in pure and pharmaceutical samples via its oxidation to reddish-orange coloured complex through oxidation by cerium (IV) sulphate in aqua medium using homemade Ayah 3Sx3-3D-solar cell CFI photometer. The colored species were determined using supper bright green light emitting diode (LED) as a source. A 100μl was taken as a best sample volume for the determination of folic acid. The linearity of calibration curve for the instrument response versus folic acid concentration was 0.005-20 mmol.L-1 while the L.O.D. was 0.5  mol.L-1 from the stepwise dilution for the minimum concentration of lowest concentration in the linear dynamic range of the calibration graph. The correlation coefficient (r) was 0.9994 while the percentage linearity (r2%) was 99.88%. The method was applied successfully for the determination of folic acid in pharmaceutical preparation. RSD% for 8 mmo.L-1 (n=6) less than 1% . Using paired t-test it was shown that there was no significant difference between the proposed method and official method (Quoted value- 5mg) and on that basis the new method can be accepted as an alternative analytical method.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Dec 01 2022
Journal Name
Baghdad Science Journal
Determination of Nickel and Cobalt in Cosmetic Products Marketed in Iraq Using Spectrophotometric and Microfluidic Paper-based Analytical Device (µPADs) Platform
...Show More Authors

Two quantitative, environment-friendly and easily monitored assays for Ni (II) and Co (III) ions analysis in different lipstick samples collected from 500-Iraqi dinars stores located in Baghdad were introduced. The study was based on the reaction of nickel (II) ions with dimethylglyoxime (DMG) reagent and the reaction of cobalt (III) ions with 1-nitroso-2-naphthol (NN) reagent to produce colored products. The color change was measured by spectrophotometric method at 565 nm and 430 nm for Ni and Co, respectively, with linear calibration graphs in the concentration range 0.25-100 mg L-1 (Ni) and 0.5-100 mg L-1 (Co) and LOD and LOQ of 0.11 mg L-1 and 0.36 mg L-1 (Ni), and 0.15 mg L-1 an

... Show More
View Publication Preview PDF
Scopus (5)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Tue May 01 2018
Journal Name
Journal Of Physics: Conference Series
Physical properties of CdS/CdTe/CIGS thin films for solar cell application
...Show More Authors

View Publication
Scopus (12)
Crossref (7)
Scopus Clarivate Crossref
Publication Date
Tue Nov 21 2023
Journal Name
Mater Sci: Mater Electron
Pulsed laser deposition of nanostructured CeO2 antireflection coating for silicon solar cell
...Show More Authors

Increasing the power conversion efficiency (PCE) of silicon solar cells by improving their junction properties or minimizing light reflection losses remains a major challenge. Extensive studies were carried out in order to develop an effective antireflection coating for monocrystalline solar cells. Here we report on the preparation of a nanostructured cerium oxide thin film by pulsed laser deposition (PLD) as an antireflection coating for silicon solar cell. The structural, optical, and electrical properties of a cerium oxide nanostructure film are investigated as a function of the number of laser pulses. The X-ray diffraction results reveal that the deposited cerium oxide films are crystalline in nature and have a cubic fluorite. The field

... Show More
View Publication
Scopus Clarivate Crossref
Publication Date
Tue Feb 13 2024
Journal Name
Iraqi Journal Of Science
Mathematical Model For Determination the Increase in Operational Cost of Transmission Line From HAD3 to QIM3 in Electric Power System
...Show More Authors

The transformation of a physical system to mathematical base is very important due to analysis of the systems behavior. In this paper an electric power system is considered, we design mathematical model for the determination of the increase in operational cost of transmission line from Haditha Dam substation to Qa'im substation . We derived relations which the approximate distance for VARS transmission must satisfy with considering minimum losses in the system. MATLAB computer programming is used to obtain the numerical results. The developed mathematical model and the numerical results could be useful to electric power systems engineers

View Publication Preview PDF
Publication Date
Sun Dec 04 2016
Journal Name
Baghdad Science Journal
Mefenamic Acid Selective Membranes Sensor and Its Application to pharmaceutical Analysis
...Show More Authors

PVC membrane sensor for the selective determination of Mefenamic acid (MFA) was constructed. The sensor is based on ion association of MFA with Dodecaphospho molybdic acid (PMA) and Dodeca–Tungstophosphoric acid(PTA) as ion pairs. Nitro benzene (NB) and di-butyl phthalate (DBPH) were used as plasticizing agents in PVC matrix membranes. The specification of sensor based on PMA showed a linear response of a concentration range 1.0 × 10–2 –1.0 × 10–5 M, Nernstian slopes of 17.1-18.86 mV/ decade, detection limit of 7 × 10-5 -9.5 × 10 -7M, pH range 3 – 8 , with correlation coefficients lying between 0.9992 and 0.9976, respectively. By using the ionphore based on PTA gives a concentration range of 1.0 × 10–4 –1.0 × 10–5 M,

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Dec 18 2017
Journal Name
Al-khwarizmi Engineering Journal
Experimental and Theoretical Study for Performance Enhancement of Air Solar Collectors by Using Different Absorbers
...Show More Authors

An experimental and theoretical study has been done to investigate the thermal performance of different types of air solar collectors, In this work air solar collector with a dimensions of (120 cm x90 cm x12 cm) , was tested under climate condition of  Baghdad city with a (43° tilt angel)  by using  the absorber plate (1.45 mm thickness, 115 cm height x 84 cm width), which was manufactured from iron painted with a black matt.

The experimental test deals with five types of absorber:-

 Conventional smooth flat plate absorber , Finned absorber , Corrugated absorber plate, Iron wire mesh on absorber And matrix of porous media  on absorber .

The hourly and average efficiency of the collectors

... Show More
View Publication Preview PDF
Publication Date
Thu Dec 22 2022
Journal Name
Chemistry & Chemical Technology
Turbidimetric Determination of Mebeverine Hydrochloride in Pharmaceutical Formulations Using Two Consecutive Detection Zones under Continuous Flow Conditions
...Show More Authors

A simple, low cost and rapid flow injection turbidimetric method was developed and validated for mebeverine hydrochloride (MBH) determination in pharmaceutical preparations. The developed method is based on forming of a white, turbid ion-pair product as a result of a reaction between the MBH and sodium persulfate in a closed flow injection system where the sodium persulfate is used as precipitation reagent. The turbidity of the formed complex was measured at the detection angle of 180° (attenuated detection) using NAG dual&Solo (0-180°) detector which contained dual detections zones (i.e., measuring cells 1 & 2). The increase in the turbidity of the complex was directly proportional to the increase of the MBH concentration

... Show More
View Publication
Scopus (6)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Tue Feb 28 2023
Journal Name
Iraqi Journal Of Science
Studying some cytotoxic and cytogenetic potentials of Dandelion methanolic extract on MCF-7 cancer cell line: an in vitro study
...Show More Authors

      This study aimed to evaluate the anticancer activity and cell division arresting by dandelion methanolic extract on breast cancer cell line MCF-7 cancer cell line. For achieving this goal, cytotoxicity assay (MTT assay), multipara system assay: High Content Screening (HCS) which include (viable cell count VCC; membrane permeability MP; cellular mitochondrial permeability CMP; nuclear intensity NI and cytochrome C releasing ), reactive oxygen species detection and cell cycle phases division were tested. The results of this study showed the ability of the plant to reduce cancer cell viability in a dose-dependant manner within IC50 (141.0) in comparison to IC50 of (334.4) on the

... Show More
View Publication Preview PDF
Scopus (4)
Crossref (1)
Scopus Crossref
Publication Date
Sun Aug 13 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
The Effect of the Thickness of Polycrystalline CdS film on the Efficiency of Cu2S/CdS Solar Cell
...Show More Authors

  In this paper, Cu2S/CdS solar cells were prepared with different thickness of CdS layer, these layers were prepared by using chemical spray pyrolysis technique. The chemical spray solution was prepared by mixing cadmium chloride CdCl2 and thiourea CS(NH2)2 of molar concentration 0.1 M/L, the CdS layer was formed after the solution was sprayed on hot Aluminum substrate at temperature 400°C. Experimentally the type of CdS film was found as n–type depending on the results of Hall Effect, the value of the Hall factor (RH) is about – 1.348 x 10–6 m3/C and the density of the majority charge carriers (N) is about 4.64x1018 cm–3.       The prepared film was tested by using X-Ray

... Show More
View Publication Preview PDF
Publication Date
Sat Feb 08 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Bone density determination for the maxilla and the mandible in different age groups by using computerized tomography (Part I)
...Show More Authors

Background: Mini implant stability is primarily related to local bone density; no studies have evaluated bone density related to mini implant placement for orthodontic anchorage between different age groups in the maxilla and the mandible. The present research aims to evaluate side, gender, age, and regional differences in bone density of the alveolar bone at various orthodontic implant sites. Materials and method: Fifty three individuals who were divided into two groups according to their age into: group I (ages 16-20 years) and group II (ages 21-29 years) had subjected to clinical examination, then 64-multislice computed tomography scan data were evaluated and bone density was measured in Hounsfield unit at 102 points (51 in the maxilla

... Show More
View Publication Preview PDF