Preferred Language
Articles
/
ijs-11541
New Approach for the On-Line Spectrophotometric Determination of Folic Acid in Pure and Pharmaceutical Preparation via Oxidation by Cerium(IV) Sulphate Using Ayah 3Sx3-3D-Solar Cell CFI Spectrophotometer Analyzer
...Show More Authors

A newly photometric analytical method characterized by its speed and sensitivity was developed for the determination of folic acid in pure and pharmaceutical samples via its oxidation to reddish-orange coloured complex through oxidation by cerium (IV) sulphate in aqua medium using homemade Ayah 3Sx3-3D-solar cell CFI photometer. The colored species were determined using supper bright green light emitting diode (LED) as a source. A 100μl was taken as a best sample volume for the determination of folic acid. The linearity of calibration curve for the instrument response versus folic acid concentration was 0.005-20 mmol.L-1 while the L.O.D. was 0.5  mol.L-1 from the stepwise dilution for the minimum concentration of lowest concentration in the linear dynamic range of the calibration graph. The correlation coefficient (r) was 0.9994 while the percentage linearity (r2%) was 99.88%. The method was applied successfully for the determination of folic acid in pharmaceutical preparation. RSD% for 8 mmo.L-1 (n=6) less than 1% . Using paired t-test it was shown that there was no significant difference between the proposed method and official method (Quoted value- 5mg) and on that basis the new method can be accepted as an alternative analytical method.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Oct 20 2023
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Pure Maximal Submodules and Related Concepts
...Show More Authors

      In this work we discuss the concept of pure-maximal denoted by (Pr-maximal) submodules as a generalization to the type of R- maximal submodule, where a proper submodule  of an R-module  is called Pr- maximal if  ,for any submodule  of W is a pure submodule of W, We offer some properties of a Pr-maximal submodules, and we give Definition of the concept, near-maximal, a proper submodule  

 of an R-module  is named near (N-maximal) whensoever  is pure submodule of  such that  then K=.Al so we offer the concept Pr-module, An R-module W is named Pr-module, if every proper submodule of  is Pr-maximal. A ring  is named Pr-ring if whole proper ideal of  is a Pr-maximal ideal, we offer the concept pure local (Pr-loc

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Apr 08 2018
Journal Name
Al-khwarizmi Engineering Journal
Experimental Study on Solar Air Heating
...Show More Authors

Abstract

 

A new type of solar air heater was designed, fabricated, and tested in Baghdad, Iraq winter conditions. The heater consists of two main parts. The horizontal section was filled with the black colored iron chip while the vertical part has five pipes filled with Iraqi paraffin wax. A fan was fixed at the exit of the air. Two cases were studied: when the air moved by natural convection and when forced convection moved it. The studied air heater has proven its effectiveness as it heated the air passing through it to high temperatures. The results manifest that using little air movement makes the temperatures, stored energies, and efficiencies of the two studied cases converge

... Show More
View Publication Preview PDF
Crossref (6)
Crossref
Publication Date
Sat Jun 01 2019
Journal Name
2019 Ieee International Conference On Automatic Control And Intelligent Systems (i2cacis)
Study on Solar Panel Cleaning Robot
...Show More Authors

View Publication
Scopus (27)
Crossref (22)
Scopus Clarivate Crossref
Publication Date
Sun Sep 04 2011
Journal Name
Baghdad Science Journal
Determination of bacterial contamination of milk using fluorometry
...Show More Authors

The aim of this paper is to determine the feasibility of using fluorometric methods as an indicator for quality and contamination of milk with E.coli bacteria, and selection the suitable wavelength to be used with laser induced auto fluorescence. Three groups of milk samples were used in this study: Fresh pasteurized milk samples, milk samples containing different concentration of E.coli bacteria which were added artificially, and milk samples that were kept in refrigerator for 3-5 days. Thirteen excitation wavelengths were used to get the emission spectra for all milk samples using spectroflourometer .The results showed that the emission spectra at 275nm excitation wavelength gave a good differentiation between these three groups.

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Jun 17 2019
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Preparation and Characterization of Some Metal Complexes of the New Ligand : 2-[ 2-(5- Methyl benzothiazolyl )azo] -4-Methyl phenol ( 5-Me-BTAC ).
...Show More Authors

 This work reports the synthesis and characterization of some Co(111), Ni(11), Cu(11), Zn(l 1), Cd(1 1) and Hg(11) chelates of the new benzothia-zolylazo Ligand ( 5-Me-BTAC ) . The compounds were Characterized by IR , electronic spectroscopy, magnetic susceptibility ,elemental analysis and molar conductance measurements . The elemental analysis suggest the formula [ ML2 ] x.nH2O where x=Cl , n=1 for M= Co(111) and x=o , n=o for the remaining metal ions Electronic spectra and magnetic susceptibility data has supported the proposed octahedral geometry of Co(111) Ni(11) and Cu(1 I) Complexes. Conductivity measurements refer to nonionic structure of these Complexes except of Co(111) .

View Publication Preview PDF
Publication Date
Sun Sep 01 2019
Journal Name
Al-khwarizmi Engineering Journal
Pneumatic Control System of Automatic Production Line Using Two Method of SCADA/HMI Implement PLC
...Show More Authors

This study focuses on the implementation of interfaces for human machine interaction (HMI) control and monitor automatic production line. The automatic production line can performance feeding, transportation, sorting functions. The objectives of this study are implemented two SCADA/HMI system using two different software. TIA portal software is used to build HMI, alarm, and trends in touch panel which is helped an operator to control and monitor the production line. LabVIEW software is used to build HMI and trends in the computer screen and is linked with Microsoft Excel (ME) to generate information table helped to monitor the performance of the pneumatic equipment. The production line can do performance feeding, transportation, sorting fun

... Show More
View Publication Preview PDF
Publication Date
Sun Sep 01 2019
Journal Name
Al-khwarizmi Engineering Journal
Pneumatic Control System of Automatic Production Line Using Two Method of SCADA/HMI Implement PLC
...Show More Authors

 

       This work focuses on the implementation of interfaces for human machine interaction (HMI) for control and monitor of automatic production line. The automatic production line which can performance feeding, transportation, sorting functions.      

            The objectives of this work are implemented two SCADA/HMI system using two different software. TIA portal software was used to build HMI, alarm, and trends in touch panel which are helped the operator to control and monitor the production line. LabVIEW software was used to build HMI and trends on the computer screen and was linked with Micros

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Jun 26 2021
Journal Name
Egyptian Journal Of Chemistry
Preparation and Diagnostics of Schiff Base Complexes and Thermodynamic Study for Adsorption of Cobalt Complex on Iraqi Attapulgite Clay Surface
...Show More Authors

View Publication
Scopus (3)
Scopus Clarivate Crossref
Publication Date
Fri Oct 14 2022
Journal Name
Diagnostics
Determination of the Accuracy of Salivary Biomarkers for Periodontal Diagnosis
...Show More Authors

Background: We aimed to investigate the accuracy of salivary matrix metalloproteinases (MMP)-8 and -9, and tissue inhibitor of metalloproteinase (TIMP)-1 in diagnosing periodontitis and in distinguishing periodontitis stages (S)1 to S3. Methods: This study was a case–control study that included patients with periodontitis S1 to S3 and subjects with healthy periodontia (controls). Saliva was collected, and then, clinical parameters were recorded, including plaque index, bleeding on probing, probing pocket depth, and clinical attachment level. Diagnosis was confirmed by assessing the alveolar bone level using radiography. Salivary biomarkers were assayed using an enzyme-linked immunosorbent assay. Results: A total of 45 patients (15

... Show More
View Publication
Scopus (16)
Crossref (19)
Scopus Clarivate Crossref
Publication Date
Mon Apr 01 2024
Journal Name
Iraqi Journal Of Oil And Gas Research (ijogr)
Comparative study of electrochemical oxidation system hybrid with photocatalytic system for the treatment of Al-Najaf petroleum refinery wastewater
...Show More Authors

View Publication
Crossref