This study was conducted to evaluate the effect of discharge of water purification plants ,on the purity of Tigris River water in Baghdad city. The two studied plants were involved in the study : Sharq –Dijla and Al-Karama water purification plants. The study was attempted to focus on probable pollutants. Chemical, physical tests were accomplished on water samples collected from four sites with fact of three replicates for each sample of each site of the river and the plant : before, after, inside the plants and at the pipe. This study started from October 2012 to September 2013. In case of heavy metals Results showed that the highest level of aluminum was 1.08 ppm during (December-January) at Sharq-Dijla plants, while the lowest level was 0.059 ppm during (August- September) at AL- Karama plants ,while results of iron which recorded the highest level 3.30 ppm during (December-January) at Sharq –Dijla plants, while the lowest level was 1.63 ppm during (August- September) at Sharq –Dijla plants. It was found that the highest level of turbidity was 119 N.T.U during (December-January) at Sharq- Dijla plants, while the lowest level was 33.0 N.T.U during ( June-July) at Sharq-Dijla plants. While the highest level of EC was 1068 μS/cm during (December-January) at Sharq-Dijla plants, while the lowest level was 693 μS/cm during ( June-July) at Sharq-Dijla plants .T.D.S recorded highest level during (December-January) at AL- Karama plants which was 687 ppm , while the lowest recorded level was 506 ppm during ( August- September) at Sharq-Dijla plants, also the highest level of T.S.S was 793 ppm during (December-January) at AL- Karama plants, while the lowest level was 410 ppm during ( August- September) at Sharq-Dijla plants .
The climate parameters annual rainfall and average mean temperature are investigated from 2000 to 2019 for Kut, Hilla and Iskandaryia. Evidence of climate change is noticed by decreasing the mean annual rainfall and relative humidity with an increase in the annual mean temperature. The climate water balance has been calculated. Due to high temperature, increased evaporation, and low precipitation rates, there was a large water deficit. The total water surplus in the Kut area is 32.86 mm from November to February, and in Hilla and Iskandaryia is 20.4 and 27.8 mm from December to February, respectively. The climate classification for the three stations was semi-dry to dry climates. The region has a significant water deficit of u
... Show MoreIn this paper thermo-hydrodynamic characteristics were investigated experimentally for a new type shell-helical coiled tube heat exchanger used as a storage tank of closed loop solar water heater system. Triple concentric helical coils were made of copper tubes of (12.5mm OD and 10mm ID) with coils diameter of (207, 152.2, 97mm) for outer, middle and inner coils respectively. The experiments were carried out during a clear sky days of (March and April 2012). The parameters studied in this work are: history of average temperature of shell side of the storage tank, collector heat gain, heat rejected from coils to shell side of the storage tank, collector efficiency, thermal effectiveness of the heat exchanger (storage tank), and pressure d
... Show MoreThe antibacterial activities of some nanoparticles, makes them attractive as a new agents against pathogenic bacteria. In this research, the antimicrobial effects of Titanium dioxide-nano-particles against seven bacterial isolates (E.coli, Enterobacter aerogenes, Pseudomonas alcaligenes, Aeromonas veronii, Aeromonas hydrophila, Serratia marcescens and Staphylococcus aureus) being isolated from different Baghdad water purification stations investigated. The physiochemical characters, which influence the quality of the drinking water for the air and water, demonstrated.The characterization of nanoparticles investigated by using Scanning Electrone Microscope, FTIR, and UV-Visible Spectrophotometer. The activity of different concentration of
... Show MoreMolecular interactions between 2-isopropenylnaphthalene-methacrylic acid (IPNMA) block copolymer( as a model for water- soluble polymer) and methanol at several temperatures were studied using fluorescence techniques , Fluorescence spectrum for (IPNMA) exhibits two emission bands at around 342 nm and 387 nm corresponding to the monomer and the excimer bands , respectively .The fluorescence spectra of dilute solution of (IPNMA) in methanol were recorded in temperature range of 8- 45?C . Plot of the excimer to monomer intensity ratio Ie/Im versus temperature was obtained, which shows double lines with positive slopes crossing at 25?C , the increasing of slope value above this temperature is s
... Show MoreThe ceiling of the midbrain has a couple of optic lobes which are prominent and used as an optic center that reflex what it receives from eye retina fibers. The histology of optic tectum has been studied in Iraqi water snake natrix tesselata tesselata . It was found that the number of optic tectum were seven main strata organized from the outside to the inside as follows : the stratum zonula (SZ), the stratum opticum (SO), the stratum fibrosum et griseum superficialis (SFGS), the stratum griseum central (SGC), the stratum album central (SAC), the stratum griseum periventricular (SGP), and the stratum album periventricular (SAP). the three last strata consider deep layers on the optic tectum It was noticed that the thinnest strata was the fi
... Show MoreAl-Yusifia river was assessed at three sampling stations with study period from Autumn 2010 to the end of Summer 2011. The present investigation was carried out on diversity of fungi and bacteria from Al-Yusifia river, Baghdad city. During the study, a total of 12 fungal genus and 6 bacterial genus were isolated during the year seasons. The dominant fungus at the three stations were Penicillium sp., then Rhizopus and Trichophyton megninii while the dominant bacteria was Escherichia coli and Klebsiella sp.
The higher
... Show MoreThe present study refers to a ready-made three components epoxy based paint made by the Modern Paints Industries Company (Al-Za'farania, Baghdad) subjected to several tests in order to improve its specifications by optimizing the application conditions. The paint components are under the trade names: Resin (D-5547), Hardener (H-1457) and Thinner (P-851). The paint is used for painting drinking water reservoirs from inside.
The problem of water scarcity is becoming common in many parts of the world, to overcome part of this problem proper management of water and an efficient irrigation system are needed. Irrigation with a buried vertical ceramic pipe is known as a very effective in the management of irrigation water. The two- dimensional transient flow of water from a buried vertical ceramic pipe through homogenous porous media is simulated numerically using the HYDRUS/2D software. Different values of pipe lengths and hydraulic conductivity were selected. In addition, different values of initial volumetric soil water content were assumed in this simulation as initial conditions. Different value
... Show MoreMandali Basin is located between latitudes (33◦ 39' 00" and 33◦
54' 55") to the north and longitudes (45ο 11' 00" and 45ο 40' 00") to the
east; to the east of Diyala province at the Iraqi-Iranian border; the
basin area is approximately 491 km2.
From the study of climate reality of the basin between 1990-
2013and assessment of the basic climate transactions, it was found
that the annual rate of rainfall is 253.02 mm, the relative humidity
(44.4%), the temperature (21.3 ◦C), wind speed (2.08 m /sec.),
sunshine (8.27 h/day) and evaporation of the basin class (a) (271.98
mm) and corrected potential evapotranspiration (80.03 mm). The
results of the data analysis show that, there are
The present study is considered the first on this sector of the Tigris River after 2003. It is designed for two aims, the first is to demonstrate the seasonal variations in physicochemical parameters of Tharthar-Tigris Canal and Tigris River; the second is to explain the possible effects of canal on some environmental properties in the Tigris River. Water samples were being collected monthly. Six sampling sites were selected, two on Tharthar Canal and four along the Tigris River, one before the confluence as a control site and the others downstream the confluence with the canal. For a period from January to December 2020, nineteen physicochemical parameters were investigated including air and water temperature, turbidity, electrical cond
... Show More