Preferred Language
Articles
/
ijs-11339
New Approach for The Turbidimetric Determination of Iron(III) in Drug Samples of Different Origins Using Homemade Linear Array Ayah 5SX1-T-1D-CFI Analyser

A new Turbidimetric method characterized by simplicity, accuracy and speed for determination of iron(III) in drug samples by continuous flow injection analysis. The method was based on the formation of complex for iron(III) with 8-hydroxyquinoline in presence of ammonium acetate as a medium for the formation of deep green precipitate and this precipitate was determined using homemade Linear Array Ayah-5SX1-T-1D continuous flow injection analyser. The optimum parameters were 2.6 mL.min-1 flow rate using H2O as a carrier, 1.9 mL.min-1 (14 mmol.L-1) ammonium acetate, 2.4 mL.min-1 (14 mmol.L-1) 8-hydroxyquinoline, 60 L sample volume and open valve for the purge of the sample segment. Data treatment shows that linear range 0.1-8.0 mmol.L-1 while L.O.D 4.8×10-9 M/sample equivalent to 16.1 pg/sample from the stepwise dilution for minimum concentration of lowest concentration in linear dynamic range of the calibration graph. The correlation coefficient (r) was 0.9911 while percentage linearity (%r2) C.O.D was 98.24%. R.S.D.% for the repeatability (n=6) was <1% for determination of iron(III) with concentration 4 and 8 mmol.L-1. The method was applied successfully for the determination of iron(III) in pharmaceutical preparations. Using paired t-test between the newly developed method and official method; shows that there were no significant differences between either methods. On this basis the new method can be accepted as an alternative analytical method for determination of iron(III) in pharmaceutical samples.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Dec 11 2023
Journal Name
Journal Of Kufa For Chemical Sciences
Review of Analytical Methodologies for the Determination of Metronidazole and Trimethoprim in Environmental Samples

Antibiotics are essential for treating infectious diseases, but their overuse and adverse effects are raising concerns about global public health. The pervasiveness of antibiotic contamination in aquatic environments has drawn increased attention in recent years. The primary concern regarding the release of antibiotics into the environment is the potential for microorganisms to become resistant to antibiotics. This review article summarizes the analytical methods used to determine the presence of trimethoprim and metronidazole in various environmental samples. These antibiotics have traditionally been analyzed using tandem mass spectrometry or high-performance liquid chromatography coupled to mass spectrometry; fluorescence or ultrav

... Show More
Preview PDF
Publication Date
Thu Dec 31 2020
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
SYNTHESIS OF THE NEW NAPROXEN SELECTIVE ELECTRODE BASED ON IMPRINTED POLYMER USING DIFFERENT MONOMERS AND ITS DETERMINATION AT PHARMACEUTICAL PREPARATION: SYNTHESIS OF THE NEW NAPROXEN SELECTIVE ELECTRODE BASED ON IMPRINTED POLYMER USING DIFFERENT MONOMERS AND ITS DETERMINATION AT PHARMACEUTICAL PREPARATION

ABSTRACT

Naproxen(NPX) imprinted liquid electrodes of polymers are built using polymerization precipitation. The molecularly imprinted (MIP) and non imprinted (NIP) polymers were synthesized using NPX as a template. In the polymerization precipitation involved, styrene(STY) was used as monomer, N,N-methylenediacrylamide (N,N-MDAM) as a cross-linker and benzoyl peroxide (BPO) as an initiator. The molecularly imprinted membranes and the non-imprinted membranes were prepared using acetophenone(AOPH) and di octylphathalate(DOP)as plasticizers in PVC matrix. The slopes and detection limits of the liquid electrodes ranged from)-18.1,-17.72 (mV/decade and )4.0 x 10-

... Show More
View Publication Preview PDF
Publication Date
Fri Jun 30 2023
Journal Name
Malaysian Journal Of Science
DETERMINATION OF URANIUM CONCENTRATIONS IN RICE SAMPLES AVAILABLE IN THE IRAQI MARKET USING THE CR-39 DETECTOR

In this study, the results of the uranium concentrations and specific activity in 10 rice samples are described using a solid-state track detector (CR-39). Samples were collected from various local Iraqi markets with different origins (Iraq, India, America, and Thailand). Our findings found that the results of uranium concentration in all studied samples are ranging from (0.55 ± 0.28 to 1.74 ± 0.31) ppm with a weighted average of (1.24 ± 0.99) ppm. Also, results demonstrate that the specific activity values of the studied samples swing between values of (6.88 ± 3.52 and 21.49 ± 3.85) Bq/Kg. The obtained results of the studied rice samples are indicated that it is less than the acceptable limit of those studies established by ma

... Show More
Scopus Crossref
View Publication
Publication Date
Fri Nov 11 2022
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Analytical Methods for Determination of Ketoprofen Drug: A review

Ketoprofen has recently been proven to offer therapeutic potential in preventing cancers such as colorectal and lung tumors, as well as in treating neurological illnesses. The goal of this review is to show the methods that have been used for determining ketoprofen in pharmaceutical formulations. Precision product quality control is crucial to confirm the composition of the drugs in pharmaceutical use. Several analytical techniques, including chromatographic and spectroscopic methods, have been used for determining ketoprofen in different sample forms such as a tablet, capsule, ampoule, gel, and human plasma. The limit of detection of ketoprofen was 0.1 ng/ ml using liquid chromatography with tandem mass spectrometry, while it was 0

... Show More
Publication Date
Wed Jul 20 2022
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Analytical Methods for Determination of Ketoprofen Drug: A review

Ketoprofen has recently been proven to offer therapeutic potential in preventing cancers such as colorectal and lung tumors, as well as in treating neurological illnesses. The goal of this review is to show the methods that have been used for determining ketoprofen in pharmaceutical formulations. Precision product quality control is crucial to confirm the composition of the drugs in pharmaceutical use. Several analytical techniques, including chromatographic and spectroscopic methods, have been used for determining ketoprofen in different sample forms such as a tablet, capsule, ampoule, gel, and human plasma. The limit of detection of ketoprofen was 0.1 ng/ ml using liquid chromatography with tandem mass spectrometry, while it was 0.01-

... Show More
Crossref (2)
Crossref
View Publication Preview PDF
Publication Date
Wed Apr 20 2022
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
A New Approach to Solving Linear Fractional Programming Problem with Rough Interval Coefficients in the Objective Function

This paper presents a linear fractional programming problem (LFPP) with rough interval coefficients (RICs) in the objective function. It shows that the LFPP with RICs in the objective function can be converted into a linear programming problem (LPP) with RICs by using the variable transformations. To solve this problem, we will make two LPP with interval coefficients (ICs). Next, those four LPPs can be constructed under these assumptions; the LPPs can be solved by the classical simplex method and used with MS Excel Solver. There is also argumentation about solving this type of linear fractional optimization programming problem. The derived theory can be applied to several numerical examples with its details, but we show only two examples

... Show More
Crossref (1)
Crossref
View Publication Preview PDF
Publication Date
Sat Jan 01 2022
Journal Name
Chemical Methodologies
Scopus (8)
Scopus
Publication Date
Sun Nov 01 2020
Journal Name
Journal Of Physics: Conference Series
Measurement of Natural Radioactivity in different cigarettes samples by using (HPGe) detector
Abstract<p>Twelve samples of cigarettes have been collected from local markets of different types and origins by using (HPGe) detector, and measurement of the specific activity for series U<sup>238</sup> and series Th<sup>232</sup> in addition to K<sup>40</sup> in order to estimate the health risk of cigarettes their by smokers, the results shown that highest specific activity value were be (12. 8±6. 3 Bq/kg, 8. 41±5. 8 Bq/kg, 125. 16±58. 3 Bq/kg), respectively, in the sample (MAC) MacBeth type cigarettes in Brazilian origin, this paper reports data such as (specific activity of K<sup>40</sup>, series U<sup>238</sup>, series Th<sup>232</sup></p> ... Show More
Crossref
View Publication
Publication Date
Thu Nov 23 2017
Journal Name
Brazilian Journal Of Analytical Chemistry
Microvolume-DLLME for the Spectrophotometric Determination of Clidinium Bromide in Drug, Urine, and Serum

The present study combines UV-Vis spectrophotometry and dispersive liquid-liquid microextraction (DLLME) for the preconcentration and determination of trace level clidinium bromide (Clid) in pharmaceutical preparation and real samples. The method is based on ion-pair formation between Clid and bromocresol green in aqueous solution using citrate buffer (pH = 3). The colored product was first extracted using a mixture of 800 µL acetonitrile and 300 µL chloroform solvents. Then, a spectrophotometric measurement of sediment phase was performed at λ = 420 nm. The important parameters affecting the efficiency of DLLME were optimized. Under the optimum conditions, the calibration graphs of standard -1 (Std.), drug, urine and serum were ranged

... Show More
Scopus (5)
Scopus
Publication Date
Sun Jun 02 2019
Journal Name
Baghdad Science Journal
New Fluorometric Method for the Determination of Ketotifen Fumarate Using Continuous Flow Injection Analysis via ISNAG-fluorimeter

        A newly developed analytical method was conducted for the determination of Ketotifen fumarate (KTF) in pharmaceuticals drugs via quenching of continuous fluorescence of 9(10H)-Acridone (ACD). The method was applied using flow injection system of a new homemade ISNAG fluorimeter with fluorescence measurements at ± 90◦ via 2×4 solar cell. The calibration graph was linear in the range of 1-45 mmol/L, with correlation coefficient r = 0.9762 and the limit of detection 29.785 µg/sample from the stepwise dilution for the minimum concentration in the linear dynamic ranged of the calibration graph. The method was successfully applied to the determination of Ketotifen fumarate in two different pharma

... Show More
Scopus (2)
Crossref (1)
Scopus Clarivate Crossref
View Publication Preview PDF