A new Turbidimetric method characterized by simplicity, accuracy and speed for determination of Hydronium ion by continuous flow injection analysis. The method was based on the formation of complex Zn3[Fe(CN)6] for Zinc(II) that was eluted by Hydronium ion from cation exchanger column with Potassium hexacyanoferrate(III) for the formation of a pale yellow precipitate and this precipitate was determined using homemade Linear Array Ayah-5SX1-T-1D continuous flow injection analyser. The optimum parameters were 2.7 mL.min-1 flow rate using H2O as a carrier stream, 1.7 mL.min-1 reagent stream, 110 L sample volume and open valve for the purge of the sample segment. Data treatment shows that linear range 0.01-0.1 mol.L-1 for each acids (HClO4,HNO3,HCl,H2SO4) while L.O.D 30, 50.01,29.75,51.41 μg/sample for HClO4,H2SO4,HCl,HNO3 respectively from the stepwise dilution for minimum concentration of lowest concentration in linear dynamic range of the calibration graph. The correlation coefficient (r) was 0.9891, 0.9930, 0.9917, 0.9940 while percentage linearity (%r2) was 97.85%, 98.81%, 98.61%, 98.36% for HClO4, H2SO4, HCl, HNO3 respectively. R.S.D. % for the repeatability (n=5) was < 2% for determination of Hydronium ion with concentration 20 and 80 mMol.L-1. The method was applied successfully for the determination of Hydronium ion in commercial samples. Using paired t-test between the newly developed method and classical method; shows that there were no significant differences between either methods. On this basis the new method can be accepted as an alternative analytical method for determination of Hydronium ion in commercial samples.
The aim of this study is to determine the effect of cold plasma on nails pH, creatine levels and the accumulative of some trace elements in humans nails. Creatine levels in the blood, as well as pH and trace elements, were measured before and after (1, 2) months of plasma exposure in both gender (men and women) between the ages of 22 and 25 years. Nails are exposed to cold plasma with a voltage of (175 volts) and (2 gas flow). After one month of exposure, there was no significant change in the levels of all parameters, but after 2 months, the concentration of creatine and pH had reached a near- neutral value. In both men and women, calcium concentration increased and showed a positive response to cold plasma, while the v
... Show MoreThe water quality index was used for the evaluation of the quality of water, as well its impacts on the rotifer abundance, in the Tigris River as it passes through Mishahda City, northern Baghdad. Five sites were selected and samples were collected during October 2019 to September 2020. It was noticed that the index values in most sites have exceeded the upper limits of river waters. The values ranged from 40 (Poor) to 45 (Marginal) in all sites. While, the values were from 42 (Poor) to 65 (Fair) during different seasons. As for drinking usages, the results demonstrated poor or undrinkable (31-40) water in all sites. Meanwhile, the values ranged from 39 (Poor) to 56 (Clear) in regard to seasons. The index values
... Show MoreIn the present work, Response Surface Methodology (RSM) was utilized to optimize process variables and find the best circumstances for indirect electrochemical oxidation of mimicked wastewater to remove phenol contaminants using prepared ternary composite electrode. The electrodeposition process is used for the synthesis of a ternary composite electrode of Mn, Co, and Ni oxides. The selected concentrations of metal salts of these elements were 0.05, 0.1, and 1.5 M, with constant molar ratio, current density, and electrolysis time of 1:1:1, 25 mA/cm2, and 2 h. Interestedly, the gathered Mn-Co-Ni oxides were deposited at both the anode and cathode. X-ray diffraction (XRD) and scanning electron microscopy (SEM) facilitated the qualitative char
... Show MoreAdsorption techniques are widely used to remove organics pollutants from waste water particularly, when using low cost adsorbent available in Iraq. Al-Khriet powder which was found in legs of Typha Domingensis is used as bio sorbent for removing phenolic compounds from aqueous solution. The influence of adsorbent dosage and contact time on removal percentage and adsorb ate amount of phenol and 4- nitro phenol onto Al-Khriet were studied. The highest adsorption capacity was for 4-nitrophenol 91.5% than for phenol 82% with 50 mg/L concentration, 0.5 gm. dosage of adsorbent and pH 6 under a batch condition. The experimental data were tested using different isotherm models. The results show that Freundlich model resulted in the best fit also
... Show MoreThe dipstick test was evaluated for sero-diagnosis of visceral leishmaniasis. We compared two types of dipstick (rKE16, rK39) tests . The sensitivity of both tests were determined using sera from fifty-two children suspected of having visceral leishmaniasis and thirty healthy children as a control group collected from Central Teaching Hospital of Pediatric in Baghdad. Fifty (96.15%) cases were confirmed to have infection by rKE16 dipstick test while, fourty-six (88.46%) cases were positive by rK39 dipstick test. Non of the sample taken from healthy control showed reactivity in any of these tests. The study indicated that rKE16 test had better sensitivity than rK39 in the diagnosis of VL(100%) ,(92 %) respectively.
In this paper, the ability of using corn leaves as low-cost natural biowaste adsorbent material for the removal of Indigo Carmen (IC) dye was studied. Batch mode system was used to study several parameters such as, contact time (4 days), concentration of dye (10-50) ppm, adsorbent dosage (0.05-0.25) gram, pH (2-12) and temperature (30-60) oC. The corn leaf was characterized by Fourier-transform infrared spectroscopy device before and after the adsorption process of the IC dye and scanning electron microscope device was used to find the morphology of the adsorbent material. The experimental data was imputing with several isotherms where it fits with Freundlich (R2 = 0.9
... Show MoreThe research involves preparing gold nanoparticles (AuNPs) and studying the factors that influence the shape, sizes and distribution ratio of the prepared particles according to Turkevich method. These factors include (reaction temperature, initial heating, concentration of gold ions, concentration and quantity of added citrate, reaction time and order of reactant addition). Gold nanoparticles prepared were characterized by the following measurements: UV-Visible spectroscopy, X-ray diffraction and scanning electron microscopy. The average size of gold nanoparticles was formed in the range (20 -35) nm. The amount of added citrate was changed and studied. In addition, the concentration of added gold ions was changed and the calibration cur
... Show MoreIn this work, the study of
This paper presents the ability to use cheap adsorbent (corn leaf) for the removal of Malachite Green (MG) dye from its aqueous solution. A batch mode was used to study several factors, dye concentration (50-150) ppm, adsorbent dosage (0.5-2.5) g/L, contact time (1-4) day, pH (2-10), and temperature (30-60) The results indicated that the removal efficiency increases with the increase of adsorbent dosage and contact time, while inversely proportional to the increase in pH and temperature. An SEM device characterized the adsorbent corn leaves. The adsorption's resulting data were in agreement with Freundlich isotherm according to the regression analysis, and the kinetics data followed pseudo-first-or
... Show More