Preferred Language
Articles
/
ijs-11280
Spectrophotometric Determination of Vancomycin Hydrochloride in Pharmaceutical Preparations through Diazotization and Coupling Reactions
...Show More Authors

Two simple, sensitive, accurate and economic methods A and B have been developed for the quantitative estimation of vancomycin hydrochlorid (VHC) and its formulations using another two drug compounds as a coupling reagents.The proposed methods are based on a coupling reaction between VHC and diazotized procain (method A) or diazotized sulphacetamide sodium (method B) in alkaline medium to form intense yellow, water-soluble dyes that are very stable and have a maximum absorption at 447 and 439 nm for methods A and B respectively. Regression analysis of Beer’s law plots showed good correlation in the concentration ranges 1-28 and 1-45 μg ml-1 for methods A and B, respectively with a molar absorbtivity of 4.605×104 L mol-1cm-1 and 4.516×104 L mol-1cm-1, Sandell's sensitivity of 0.032 g.cm-2 and 0.033 g.cm-2 for methods A and B respectively. Relative standard deviation (RSD%) were less than 2.9 for both methods.The methods were successfully applied to the determination of VHC in bulk drug and its formulations.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Aug 23 2017
Journal Name
Journal Of Physics G: Nuclear And Particle Physics
Shell closures in Fl superheavy isotopes via determination of alpha decay preformation factor
...Show More Authors

View Publication
Scopus (7)
Crossref (7)
Scopus Clarivate Crossref
Publication Date
Mon Mar 23 2020
Journal Name
Baghdad Science Journal
Quantitative Determination of Fluoroquinolones in Contaminated Soils by HPLC with Solid-Phase Extraction
...Show More Authors

This work reports the development of an analytical method for the simultaneous analysis of three fluoroquinolones; ciprofloxacin (CIP), norfloxacin (NOR) and ofloxacin (OFL) in soil matrix. The proposed method was performed by using microwave-assisted extraction (MAE), solid-phase extraction (SPE) for samples purification, and finally the pre-concentrated samples were analyzed by HPLC detector. In this study, various organic solvents were tested to extract the test compounds, and the extraction performance was evaluated by testing various parameters including extraction solvent, solvent volume, extraction time, temperature and number of the extraction cycles. The current method showed a good linearity over the concentration ranging from

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Sat Dec 15 2018
Journal Name
Revista De Chimie
Determination of Ethanol in Fermented Broth by Headspace Gas Chromatography using Capillary Column
...Show More Authors

The gas chromatography (GC) method in analytical chemistry is a quick and accurate method to detect volatile components like ethanol. A method for determining volatile components known as Headspace chromatography (HS-GC) was developed along with an internal standard method (ISM) to identify ethanol in fermented broth in the laboratory. The aim of this research is determining the concentration of ethanol in fermented broth using capillary column (ZB-1). This method can analyze ethanol concentrations in the fermented medium broth ranging from 10 to 200 g/L. The validation of this method was done in order to obtain the results to be of high precision and the significant, precision was represented as the relative standard deviation (RSD) which

... Show More
Crossref (3)
Crossref
Publication Date
Thu Nov 30 2023
Journal Name
Iraqi Journal Of Science
Determination of Spacewise− Dependent Heat Source Term in Pseudoparabolic Equation from Overdetermination Conditions
...Show More Authors

      This paper examines the finding of spacewise dependent heat source function in pseudoparabolic equation with initial and homogeneous Dirichlet boundary conditions, as well as the final time value / integral specification as additional conditions that ensure the uniqueness solvability of the inverse problem. However, the problem remains ill-posed because tiny perturbations in input data cause huge errors in outputs. Thus, we employ Tikhonov’s regularization method to restore this instability. In order to choose the best regularization parameter, we employ L-curve method. On the other hand, the direct (forward) problem is solved by a finite difference scheme while the inverse one is reformulated as an optimization problem. The

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Crossref
Publication Date
Thu Nov 21 2019
Journal Name
Journal Of Engineering
Automatic Determination of Liquid's Interface in Crude Oil Tank using Capacitive Sensing Techniques
...Show More Authors

The petroleum sector has a significant influence on the development of multiphase detection sensor techniques; to separate the crude oil from water, the crude oil tank is used. In this paper, a measuring system using a simple and low cost two parallel plate capacitance sensor is designed and implemented based on a Micro controlled embedded system plus PC to automatically identify the (gas/oil) and (oil/water) dynamic multi-interface in the crude oil tank. The Permittivity differences of two-phase liquids are used to determine the interface of them by measuring the relative changes of the sensor’s capacitance when passes through the liquid’s interface. The experiment results to determine the liquid’s interface is sa

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Sep 04 2011
Journal Name
Baghdad Science Journal
Determination of Uranium Concentration in Sheep Organs for Some Iraqiۥs Cities
...Show More Authors

The aim of this research is to determine the uranium concentration and its distribution in many sheep organs that live in different region of Iraq. The uranium concentration in tissue samples is measured by using fission tracks registration in CR-39 detector that caused by the bombardment of U235 with thermal neutrons from (241Am-Be) neutron source of thermal flux (5x 103 n.cm-2. s-1). The results show that the maximum uranium concentration in bronchiole tissues of the animals was found in Karbala city (3.706ppm) while the minimum concentration (0.127 ppm) was found in Al-Faluja city, also the same result in lung tissue the maximum value was found in Karbala city (2.313ppm) and the minimum concentration in Al Fluja (0.082). Otherwise,

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Jan 07 2016
Journal Name
Ibn Al-haitham Jour. For Pure & Appl. Sci.
Determination of Some Trace Element Levels in Iraqi Male patients with Colorectal Cancer
...Show More Authors

Alterations of trace element concentrations adversely affect biological processes and could promote carcinogenesis. Trace element deficiency or excess is implicated in the development or progression of some cancers like colorectal cancer. The aim of the present study was to compare the serum copper (Cu) and zinc (Zn) concentrations in patients with colorectal cancer from Iraqi male patient with those of healthy subjects. During the period of March 2015 until august 2015, a total of 25 patients with metastatic colon cancer and 20 healthy volunteers were enrolled from the Al-Kadhimia Teaching Hospital after the diagnosis using a histopathological examination for the malignant tumor; their age was between (38-60) years. Higher levels o

... Show More
Publication Date
Mon Feb 01 2010
Journal Name
Food Chemistry
Determination of aflatoxins in animal feeds by HPLC with multifunctional column clean-up
...Show More Authors

A reversed-phase HPLC method with fluorescence detection for the determination of the aflatoxins B1, B2, G1 and G2 in 42 animal feeds, comprising corn (16), soya bean meal (8), mixed meal (13), sunflower, wheat, canola, palm kernel, copra meals (1 each) was carried out. The samples were first extracted using acetonitrile:water (9:1), and was further cleaned-up using a multifunctional column. Optimum conditions for the extraction and chromatographic separation were investigated. By adopting an isocratic chromatographic system using a mobile phase comprising acetonitrile:methanol:water (8:27:65, v/v/v), the separation of the four aflatoxins was possible within 30 min. Recoveries for aflatoxins B1, B2, G1 and G2 were 98 ± 0.7%, 95 ± 1.0%, 94

... Show More
View Publication
Scopus (110)
Crossref (95)
Scopus Clarivate Crossref
Publication Date
Sat Mar 11 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Determination of Some Trace Element Levels in Iraqi Male patients with Colorectal Cancer
...Show More Authors

   Alterations of trace element concentrations adversely affect biological processes and could promote carcinogenesis. Trace element deficiency or excess is implicated in the development or progression of some cancers like colorectal cancer. The aim of the present study was to compare the serum copper (Cu) and zinc (Zn) concentrations in patients with colorectal cancer from Iraqi male patient with those of healthy subjects. During the period of March 2015 until august 2015, a total of 25 patients with metastatic colon cancer and 20 healthy volunteers were enrolled from the Al-Kadhimia Teaching Hospital after the diagnosis using a histopathological examination for the malignant tumor; their age was between (38-60) years. Higher

... Show More
View Publication Preview PDF
Publication Date
Wed Jul 01 2015
Journal Name
Journal Of The Faculty Of Medicine Baghdad
Determination of Serum Adiponectin Levels in Normal Weight Women with Polycystic Ovary Syndrome
...Show More Authors

Background: Polycystic ovary syndrome (PCOS) is a common endocrine disorder in women of reproductive age with primary manifestations of infertility, menstrual dysfunction and clinical or biochemical hyperandrogenism (hirsutism, acne and elevated androgen). Adiponectin is the most abundant adipokine. It has insulin-sensitizing, anti-atherogenic, and antiinflammatory actions.
Objective: Low adiponectin levels in women with PCOS have been largely attributed to obesity which is common among these patients. Therefore, the aim of this study was to measure adiponectin levels in normal weight women with PCOS and its contribution to development of disease.
Subjects and Methods: Fifty two (52) women were include

... Show More
View Publication Preview PDF
Crossref (1)
Crossref