Preferred Language
Articles
/
ijs-1090
Effects of Laser at 810 Nm on Wound Healing in Albino Mice
...Show More Authors

Many researches focused on laser therapy of wound healing in different animal models due to the lack of a standard protocol in the application of such phototherapy. Objective:  To study the effects of 810nm laser at a constant irradiance of 41.63 mw/cm2 and exposure (illumination) time of 5,15  minutes on wounds created on Albino mice (BALB/c).

     Skin wound with elliptic shape and full thickness was created on the dorsal side of  â€˜45 mature male albino mice. Irradiated animals were divided into two main groups based on irradiation time, the first was irradiated for 5 min and the second for 15 min, each was subdivided into three subgroups (n=5) according to number of treatment days (3, 5 and 10 days).   Both treated and respective control (n=15) subgroups were sacrificed on days 3, 5 and 10 posttreatment.  Laser therapy was applied using a 810 nm diode laser with a continuous wave, an output power of 400 mw, and irradiance of 41.63. The 5 min dose was 12 .5 J/cm2, whereas the 15 min dose was 37.4 J/cm2. The shape of the laser beam was fitted with a convex lens as ‘beam expander’ to irradiate a circular area of 3.4 cm diameter. Laser therapy was started after surgery and repeated for 3, 5 and 10 days, while its effects were examined by histological evaluation. Results:  At day 3 of treatment with near infrared 810nm laser at doses of 12.5J/cm² and 37.4J/cm², there was no evidence of wounds healing in irradiated groups which showed no differences with the respective control groups. At day 5 of treatment, the results showed an important increase in the scores of the parameters of wound healing (formation of granulation tissue and collagen deposition) in the irradiated groups. Near infrared 810nm laser had photobiostimulation effects on wound healing at irradiance of 41.63mW/cm² and doses of 12.5J/cm² for 5 minutes and 37.4J/cm² for 15 minutes exposure time. A complete picture of wound healing response appeared in all irradiated groups within 10 days of treatment, as expressed by complete ‘re-epithelialization’, moderate granulation tissue formation, and presence of collagen fibers, while incomplete wound healing response was observed in un-irradiated control groups within the same period. The study showed that 810 nm laser therapies had significant effects on wound healing, especially at a dose of 37.4J/cm².

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Nov 28 2020
Journal Name
Iraqi Journal Of Science
Effects of Some Cyanophyta Along with the Reduced Levels of Chemical Fertilizers on the Growth and Yield of Wheat
...Show More Authors

The present work was conducted in the fields of Al-Sewarah and Kurkok stations which belong to the State Board of Agricultural Researches, Ministry of Agriculture, Iraq during the growing season of 2018. The goal of the study was to test the effects of the application of cyanobacteria  (Anabaena circinalis and Nostoc commune) alone or in combination with reducing the dose of chemical fertilizers (CFs), which consisted of diammonium phosphate (DAP) and urea (46% nitrogen), on growth, yield and yield components of wheat cv. IPA99. Application of 50%  and 100% of CFs without cyanobacteria as well as control (without cyanobacteria and CFs) were also included in this study for comparison.

The resul

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (2)
Scopus Crossref
Publication Date
Mon Oct 01 2018
Journal Name
Iraqi Journal Of Physics
Spectroscopic analysis of magnesium-aluminum alloys by laser induced breakdown spectroscopy
...Show More Authors

In this work, the spectra of plasma glow produced by Nd:YAG laser operated at 1.064 μm on Al-Mg alloys with same molar ratio samples in air were analyzed by comparing the atomic lines of aluminum and magnesium with that of strong standard lines. The effect of laser energies on spectral lines, produced by laser ablation, were investigated using optical spectroscopy, the electron density was measured utilizing the Stark broadening of magnesium-aluminum lines and the electron temperature was calculated from the standard Boltzmann plot method. The results that show the electron temperature increases in magnesium and aluminum targets but decreases in magnesium: aluminum alloy target, also show the electron density increase all the aluminum,

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Sep 29 2019
Journal Name
Iraqi Journal Of Science
Optical Properties of Mixed ZnO: Fe2O3 Grown via Pulsed laser deposition
...Show More Authors

In this study, mixing of  zinc oxide (ZnO) nanoparticles with iron oxide(Fe2O3) at      (0, 0.1, 0.3, 0.5 and 1)%wt., are deposited on glass substrates by pulsed laser deposition (PLD) technique for study characterization ZnO:Fe2O3 as solar cell electrode. The profound effect of mixed film on the structural and optical of ZnO: Fe2O3 thin films was observed. Meanwhile, the films have polycrystalline Hexagonal structures for ZnO, Rhombohedra and cubic structure for Fe2O3, and as indicated by the X-ray diffraction patterns of the films. The mean crystallite size of ZnO increase with increasing mixed ratio. The direct energy

... Show More
View Publication Preview PDF
Scopus (5)
Scopus Crossref
Publication Date
Sat Feb 26 2022
Journal Name
Iraqi Journal Of Science
Spectroscopic Analysis of CdO: Fe Plasma Generated by Nd: YAG Laser
...Show More Authors

     In this work, the optical emission spectrum technique was used to analyze the optical emission spectrum of (CdO: Fe) plasma produced by laser Nd: YAG with a wavelength of (532) nm, a period of 10 ns, and a focal length of 10 cm in the energy range of (200-500) mJ. The electron temperature (Te) was determined using the method of line intensities ratio. Using the Saha-Boltzmann equation, the electron density (ne) was determined. Other plasma parameters such as plasma frequency (fp), Debye length (λD) and Debye number (ND) were also measured. The CdO: Fe (at a mixing ratio of X= 0.5.) plasma spectrum was observed for different energies. As a fu

... Show More
View Publication Preview PDF
Scopus (21)
Crossref (17)
Scopus Crossref
Publication Date
Tue Sep 01 2020
Journal Name
Iraqi Journal Of Physics
Enhancment of the corrosion resistance of copper metal by laser surface treatment
...Show More Authors

In this work, the copper metal was treated using Nd:YAG laser with energy 1Joul to enhance corrosion resistance and improve surface properties. The copper metal has many applications in industry as well as water, oil and gas pipes. The same conditions, (laser power density, scan speed, distance between paths, medium gas-air) were applied in the laser surface treatment, After laser treatment, the samples microstructures were investigated using optical microscope (OM) to examine micro structural changes due to laser irradiation. Specimen surfaces were investigated using atomic force microscopy (AFM), X-ray diffraction (XRD), macro hardness, and corrosion test before and after laser treatment to

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Sat Oct 29 2022
Journal Name
Current Trends In Geotechnical Engineering And Construction
Automatic Co-registration of UAV-Based Photogrammetry and Terrestrial Laser Scanning in Urban Areas
...Show More Authors

View Publication
Scopus (1)
Scopus Crossref
Publication Date
Fri Feb 08 2019
Journal Name
Iraqi Journal Of Laser
One dimensional Finite Element Solution of Moving Boundaries in Far IR Laser Tissue Ablation
...Show More Authors

In this work, the finite element analysis of moving coordinates has been used to study the thermal behavior of the tissue subjected to both continuous wave and pulsed CO2 laser. The results are compared with previously published data, and a good agreement has been found, which verifies the implemented theory. Some conclusions are obtained; As pulse width decreases, or repetition rate increases, or fluence increases then the char depth is decreased which can be explained by an increase in induced energy or its rate, which increases the ablation rate, leading to a decrease in char depth. Thus: An increase in the fluence or decreasing pulse width or increasing repetition rate will increase ablation rate, which will increase the depth of cut

... Show More
View Publication Preview PDF
Publication Date
Wed Jun 10 2009
Journal Name
Iraqi Journal Of Laser
The performance of a passively Q-switched Cr:YAG4+ in an end- pumped laser system
...Show More Authors

A characteristic study of a passively Q-switched diode pumped solid state laser system is presented in this work. For laser a comparison study for the theoretically calculated results with a simulation results using a software which calculates the Q-switched solid state laser parameters was such as energy, peak power and pulse width were performed. There was a good agreement between our theoretical calculations and the simulation values.

View Publication Preview PDF
Publication Date
Tue Sep 01 2020
Journal Name
International Journal Of Hydrogen Energy
Hydrogen gas sensing based on nanocrystalline SnO2 thin films operating at low temperatures
...Show More Authors

View Publication
Scopus (32)
Crossref (28)
Scopus Clarivate Crossref
Publication Date
Fri Feb 08 2019
Journal Name
Iraqi Journal Of Laser
Study the Effect of Annealing on Optical and Electrical Properties of ZnS Thin Film Prepared by CO2 Laser Deposition Technique
...Show More Authors

In this work, ZnS thin films have been deposited by developed laser deposition technique on glass substrates at room temperature. After deposition process, the films were annealed at different temperatures (200ºC , 300 ºC and 400ºC ) using thermal furnace.The developed technique was used to obtain homogeneous thin films of ZnS depending on vaporization of this semiconductor material by continuous CO2 laser with a simple fan to ensure obtaining homogeneous films. ZnS thin films were annealed at temperature 200ºC, 300 ºC and 400ºC for (20) minute in vacuum environment. Optical properties of ZnS thin film such as absorbance, transmittance, reflectance, optical band gap, refractive index extinction coefficient and absorption coefficien

... Show More
View Publication Preview PDF