Preferred Language
Articles
/
ijs-10456
Measuring the concentration of Suspended Particulate Matter and some heavy metals in air of two areas of Rusafa in Baghdad
...Show More Authors

This study aimed to detect the present levels and distribution of air pollutants such as SPM, Pb, Cr, Cd , and Ni , in two urban sites within Al- Rusafa side in Baghdad city (Al-Waziriya as industrial site and Al-Andalus square as commercial site). Measurements were carried out from November 2013 until June 2014. SPM, Pb, Cr, Cd , and Ni were measured using Air intake device(Sniffer) . The average minimum concentrations of SPM, Pb, Cr, Cd , and Ni were 588 μg/m3, 2.8 μg/m3, 15.6 μg/m3, 0.1 μg/m3, and 6.3 μg/m3. While the average maximum concentrations were 723 μg/m3 , 3.4 μg/m3 , 21.7 μg/m3 , 0.125 μg/m3 , and 6.8 μg/m3 , respectively. The results indicate that commercial site was more polluted with SPM , Pb , and Ni compared to the industrial site, while Cr and Cd concentrations were high in industrial site .

View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Oct 05 2022
Journal Name
Research Journal Of Chemistry And Environment
Synthesis, Antioxidant ability and Docking study for new 4, 4'-((2-(Aryl)-1H-benzo [d] imidazole-1, 3 (2H)-diyl) bis (methylene)) diphenol
...Show More Authors

New series of 4, 4'-((2-(Aryl)-1H-benzo [d] imidazole-1, 3 (2H)-diyl) bis (methylene)) Diphenol (3a-g) was successfully synthesized from cyclization of the reduction product of bis Schiff bases (2) with aryl aldehydes bearing phenolic hydroxyl in the presence of acetic acid. The structure of these compounds was identified from FT-IR, 1H NMR, 13C NMR and EIMs. The Antioxidant capability was screened by DPPH and FRAP assays. Both assays showed antioxidant capability more than BHT as well. Compounds 3b and 3c showed antioxidant capacity slightly less than ascorbic acid. The docking study for theses compound was carried out as III DNA polymerase inhibitor. The results of docking demonstrated that the increase in hinderances around phenolic hydr

... Show More
Publication Date
Tue Sep 27 2022
Journal Name
Al–bahith Al–a'alami
Motives for public exposure to advertisement through smart phone applications and its purchasing decisions relationship (A research drawn from a Master Degree thesis)
...Show More Authors

Advertisement on smart phone shopping apps are a new way of driving users to satisfy their needs and influence their purchasing decisions, In this way, the research could be aimed to know The role of the relationship between the motivations for audience exposure to shopping apps advertisement and purchasing decisions, In order to achieve the objectives of the research, the researcher adopted the survey method and used the questionnaire and the scale to collect data and information, The researcher chose the "random sample multi stages", The sample size was (475) respondents from Baghdad city center (18 years and above) women and men.

View Publication Preview PDF
Crossref
Publication Date
Sat Jun 01 2024
Journal Name
Case Studies In Chemical And Environmental Engineering
Congo red removal from aqueous solution by electrocoagulation- electro-oxidation combined system with Al and Cu–Mn–Ni nano composite as efficient electrodes
...Show More Authors

Removing Congo red (CR) is critical in wastewater treatment. We introduce a combination of electrocoagulation (EC) and electro-oxidation (EO) to address the elimination of CR. We also discuss the deposition of triple oxides (Cu–Mn–Ni) simultaneously on both anodic and cathodic graphite electrodes at constant current density. These electrodes efficiently worked as anodes in the EC-EO system. The EC-CO combination eliminated around 98 % of the CR dye and about 95 % of the Chemical Oxygen demand (COD), and similar results were obtained with the absence of NaCl. Thus, EC-EO is a promising technique to remove CR in an environmentally friendly pathway.

View Publication
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Wed Dec 13 2017
Journal Name
Al-khwarizmi Engineering Journal
A Comparison Between Recursive Least-Squares (RLS) and Extended Recursive Least-Squares (E-RLS) for Tracking Multiple Fast Time Variation Rayleigh Fading Channel
...Show More Authors

In order to select the optimal tracking of fast time variation of multipath fast time variation Rayleigh fading channel, this paper focuses on the recursive least-squares (RLS) and Extended recursive least-squares (E-RLS) algorithms and reaches the conclusion that E-RLS is more feasible according to the comparison output of the simulation program from tracking performance and mean square error over five fast time variation of Rayleigh fading channels and more than one time (send/receive) reach to 100 times to make sure from efficiency of these algorithms.

View Publication Preview PDF
Publication Date
Thu Aug 29 2024
Journal Name
European Journal Of Orthodontics
Poly-ether-ether-ketone (PEEK) versus dead-soft coaxial bonded retainers: a randomized clinical trial. Part 1. Stability, retainer failure, and participant satisfaction
...Show More Authors
Abstract<sec> <title>Background

Poly-ether-ether-ketone (PEEK) was introduced in dentistry as an alternative to metal alloys.

Objective

To assess the effectiveness of PEEK-fixed retainers in preserving the stability of mandibular anterior and participant satisfaction as compared to the Dead-soft coaxial fixed retainer (DSC).

Trial design

A single-centre, two-arm parallel groups

... Show More
View Publication
Scopus Clarivate Crossref
Publication Date
Mon Jan 01 2024
Journal Name
Journal Of Oral Medicine And Oral Surgery
Evaluating dental implant stability using three devices Osstell<sup>®</sup>, Periotest<sup>®</sup>, and AnyCheck<sup>®</sup>: a clinical study
...Show More Authors

Introduction: Implant stability is usually measured with resonance frequency analysis (RFA) and damping capacity assessment (DCA). This study aimed to measure primary and secondary stabilities using 3 devices that are based on these methods, namely; RFA (Osstell®) and DCA (Periotest® and AnyCheck®) to assess the correlations of the measurements obtained by these devices and the correlations between implant stability and insertion torque. Material and Methods: This observational prospective study included 35 dental implants. The implant stability was measured using the 3 devices. Mann–Whitney U

... Show More
View Publication
Crossref
Publication Date
Tue Jun 30 2015
Journal Name
Al-khwarizmi Engineering Journal
Laser Peening on Aluminum Alloy 7049 Using Black Paint Surface Coating
...Show More Authors

Abstract

Black paint laser peening (bPLP) technique is currently applied for many engineering materials , especially for aluminum alloys due to high improvement in fatigue life and strength . Constant and variable   bending fatigue tests have been performed at RT and stress ratio R= -1 . The results of the present  work observed that the significance of the surface work hardening which generated high negative residual stresses in bPLP specimens .The fatigue life  improvement factor (FLIF)  for bPLP constant fatigue behavior was from 2.543 to 3.3 compared to untreated  fatigue and the increase in fatigue strength at 107 cycle was 21% . The bPLP cumulative fatigue life behav

... Show More
View Publication Preview PDF
Publication Date
Sun Mar 04 2018
Journal Name
Iraqi Journal Of Science
Assessment of ISNAG fluorimeter (Total fluorescence measurements at+ 90° & - 90° using four solar cell on each side for 100mm distance at 2mm path length) with well-known fluorescent molecules via CFIA
...Show More Authors

Two well-known fluorescent molecules: fluorescein sodium salt (FSS) and 2,7-dichloro fluorescein (DCF) were tried to prove the efficiency, trustability and repeatability of ISNAG fluorimeter by using discrete and continuous flow injection analysis modes.A linear range of 0.002-1 mmol/L for FSS and 0.003-0.7 mmol/L was for DCF, with LOD 0.0018 mmol/L and 0.002 mmol/L for FSS and DCF respectively, were obtained for discrete mode of analysis. While the continuous mode gave a linear range of 0.002-0.7 mmol/L and 0.003-0.5 mmol/L for FSS and DCF respectively, the LOD were 0.0016mmol/L and 0.0018 mmol/L for FSS and DCF respectively. The results were compared with classical method at variable λex for both fluorescent molecules at 95

... Show More
View Publication Preview PDF
Publication Date
Sun Jul 31 2022
Journal Name
Iraqi Journal Of Science
Characterization Studies on Mn(II), Co(II), Ni(II), Cu(II), Zn(II) and Cd(II) Complexes with New Ligands Derived from Anthraquinone Substance
...Show More Authors

     This work involves preparation of new metal complexes via reaction of two anthraquinone ligands with Mn(II), Co(II), Ni(II), Cu(II), Zn(II) and Cd(II) metal ions . The ligands are prepared by treatment of 1- and 2-anthraquinone with acetic anhydride.

      The complexes are characterized by different physicochemical methods; microelemental analysis, molar conductivity, FT-IR, UV-Vis spectra and magnetic measurements. The discussion of the outcome data of the prepared complexes indicates that all complexes are octahedral.

      The biological activity properties of the ligands and most of their complexes are studied using gram-positive and gram-negative bacteria, which indicate that only two of th

... Show More
View Publication Preview PDF
Scopus (3)
Scopus Crossref
Publication Date
Sun Sep 06 2009
Journal Name
Baghdad Science Journal
Magic square
...Show More Authors

In this paper we introduce two Algorithms, the first Algorithms when it is odd order and how we calculate magic square and rotation for it. The second Algorithms when it be even order and how to find magic square and rotation for it.

View Publication Preview PDF
Crossref