Sediments samples from ten stations along the Euphrates River and seven
samples from selected springs within Al –Anbar governorate, (western part of Iraq),
were collected and analyzed for radioactivity. Sediments samples were dried at 100
ºC for 24 hours. Radioactivity in 1 kg of each sample was measured using gamma
spectrometer system based on a pure germanium detector with efficiency 30%. The
activity of Ra-226, Th-232, K-40 were measured to be within the typical average of
the radioactivity in sediment in world rivers, while relatively elevated concentration
were found in the sediment of some of the studied spring. In current study activity
concentrations of Cs-137 in the sediments were detected which may be caused by
the global fallout as well as caused by transferring of cesium from the relatively high
concentration areas in western desert by the rainwater within the valleys to the
sediments of the Euphrates. The radiological aspects were investigated by
calculating the radiological hazard indices such as absorbed dose rate, annual
effective dose equivalent, hazard indices and gamma index. The radiological hazard
indices were below the recommended international values. Ra-226 and Cs-137
concentrations in water and radiation doses due to drink water of the Euphrates
River were estimated. The maximum estimated interior doses which caused by 137Cs
and 226Ra in water were found to be 1.93 x 10-5mSv/y and 4.01x10-3mSv/y,
respectively.
BACKGROUND: Transverse fractures of the patella are important fractures with a wide variety of subtypes, the common incidence in the age group of 20–50 years. Surgical interference aims to achieve a perfect alignment of the joint surface, in addition to rigid fixation of the fracture for early re-habitation and early movement to retain the extensor mechanism of the knee joint. AIM: The aim of this study was to compare the radiological and functional outcomes of the displaced transverse patella fracture in adult patients treated by ORIF using tension band wiring versus cannulated screws with wiring. METHODS: A prospective analytic comparative study was conducted in Al-Kindy Teaching Hospital/Baghdad/Iraq for 18 months from Apr
... Show More<span lang="EN-US">The fundamental of a downlink massive multiple-input multiple-output (MIMO) energy- issue efficiency strategy is known as minimum mean squared error (MMSE) implementation degrades the performance of a downlink massive MIMO energy-efficiency scheme, so some improvements are adding for this precoding scheme to improve its workthat is called our proposal solution as a proposed improved MMSE precoder (PIMP). The energy efficiency (EE) study has also taken into mind drastically lowering radiated power while maintaining high throughput and minimizing interference issues. We further find the tradeoff between spectral efficiency (SE) and EE although they coincide at the beginning but later their interests become con
... Show MoreObjectives: To assess nurses-midwives' knowledge about pain management during labor before and after implementation of educational program and to determine the effectiveness of educational program on nurses-midwives' knowledge about pain management during labor in Baghdad Maternity Hospitals.
Methodology: A quasi-experimental design has been conducted during the period of (February 27th 2019 through 2nd June 2019) on non-probability sample (purposive) consists of (44 Nurses/midwives') who are work in delivery room, the sample was exposed to pretest, educational program, posttest. The study was conducted in three Directories, (Baghdad Teaching Hospital) at medical city health
... Show MoreIn this paper, a miniaturized 2 × 2 electro-optic plasmonic Mach– Zehnder switch (MZS) based on metal–polymer–silicon hybrid waveguide is presented. Adiabatic tapers are designed to couple the light between the plasmonic phase shifter, implemented in each of the MZS arms, and the 3-dB input/output directional couplers. For 6 µm-long hybrid plasmonic waveguide supported by JRD1 polymer (r33= 390 pm/V), a π-phase shift voltage of 2 V is obtained. The switch is designed for 1550 nm operation wavelength using COMSOL software and characterizes by 2.3 dB insertion loss, 9.9 fJ/bit power consumption, and 640 GHz operation bandwidth
Abstract: Aluminum alloys grade 6061-T6 are characterized by their excellent properties and processing characteristics which make them ideal for varieties of industrial applications under cyclic loading, aluminum alloys show less fatigue life than steel alloys of similar strength. In the current study, a nanosecond fiber laser of maximum pulse energy up to 9.9 mJ was used to apply laser shock peening process (LSP) on aluminum thin sheets to introduce residual stresses in order to enhance fatigue life under cyclic loading Box-Behnken design (BBD) based on the design of experiments (DOE) was employed in this study for experimental design data analysis, model building and optimization The effect of working parameters spot size (ω), scannin
... Show MoreA study was carried out to analysis of some heavy metals in nine different types of vinegar, belong to Grape, Apple, Synthetic White, Date, Hawthorn, Garlic, Cactus, Pomegranate and Ginger vinegar, which are locally available in Iraqi folk medicine markets. The concentrations of heavy metals in the studied samples including, Cr, Mg, Mn, Zn, Fe, Cd, Ni, Pb and Ag, were determining by using flame atomic absorption spectrophotometry. All data were subjected to statistical analysis by calculating accuracy, precision and correlation coefficient for each concentrations level. The results indicate that Ni was recorded the highest concentration in all studied samples except, Ginger and cactus vinegar, each one receded the highest concentration valu
... Show MoreMRY *Khalid Sh. Sharhan, *Naseer Shukur Hussein, INTERNATIONAL JOURNAL OF DEVELOPMENT IN SOCIAL SCIENCE AND HUMANITIES, 2021
The solidification process in a multi-tube latent heat energy system is affected by the natural convection and the arrangement of heat exchanger tubes, which changes the buoyancy effect as well. In the current work, the effect of the arrangement of the tubes in a multi-tube heat exchanger was examined during the solidification process with the focus on the natural convection effects inside the phase change material (PCM). The behavior of the system was numerically analyzed using liquid fraction and energy released, as well as temperature, velocity and streamline profiles for different studied cases. The arrangement of the tubes, considering seven pipes in the symmetrical condition, are assumed at different positions in the system, i
... Show More