Preferred Language
Articles
/
ijp-982
Enhanced Mechanical Property of Acrylic Polymer/Graphene/Carbon Fibers Hybrid for Water Proof Coating
...Show More Authors

In this work, some mechanical properties of the polymer coating were improved by preparing a hybrid system containing Graphene (GR) of different weight percentages (0.25, 0.5, 1, and 2wt%) with 5wt% carbon fibres (CF) and added to a polymer coating by using casting method. The properties were improved as GR was added with further improvement on adding 5wt% of CF. The impact strength of acrylic polymer with GR increases with increasing weight ratio‏‏ of GR; maximum value was obtained when the polymer coating was incorporated with 1wt% GR and 5wt% CF. The impact strength of acrylic polymer with GR and GR/CF composites incorporated with GR at 1wt% and CF at 5wt%. Hardness increase with increasing weight ratio of Gr and a significant improvement was observed at 1wt% GR and 5wt% CF content. The tensile strength increases more significantly than the acrylic polymer with GR and GR/CF composites incorporated with GR at 1wt% and CF at 5wt%. Pull-off strength for the polymer coating with GR and CF was greater than for the acrylic polymer coating.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Aug 19 2022
Journal Name
International Journal Of Health Sciences
A study of the mechanical and electrical activities of the heart and their relationship to the phosphagenic and lactic energy systems of young basketball players
...Show More Authors

It was found that there was a significant correlation between all tests of the mechanical and electrical activity of the heart (systolic force FC, stroke volume SV, end-diastolic volume, EF volume, and left ventricular volume during diastole LVDD) with the test of the oxygen-phosphating energy system (Markaria). - As safe (Margaria-Kalamen( It was found that there is a significant correlation between all tests of the mechanical and electrical activity of the heart (myocardial systolic force FC, stroke volume SV, end-diastolic volume EDV, and the percentage of heart pumpingEF blood, and left ventricular volume during diastole (LVDD) with the Lactational Oxygen Energy System Test (Wingate Test 30 Second(

View Publication Preview PDF
Crossref
Publication Date
Mon Oct 05 2015
Journal Name
Diyala Journal For Pure Science
Determination of zinc ions in drinking water distribution systems (PVC pipes) by spectrophotometric method
...Show More Authors

In this work, a method for the simultaneous spectrophotometric determination of zinc which was precipitated into deionized water that is in a commercial distribution systems PVC pipe, is proposed using UV-VIS Spectrophotometer. The method based on the reaction between the analytes Zn2+ and 2-carboxy-2-hyroxy-5-sulfoformazylbenze (Zincon) at an absorption maximum of 620nm at pH 9-10. This ligand is selective reagent. Since the complex is colored (blue), its stoichiometry can be established using visible spectrometry to measure the absorbance of solutions of known composition. The stoichiometry of the complex was determined by Job’s method and molar ratio method and found to be 1:2 (M: L). A series of synthetic solution containing different

... Show More
Publication Date
Sun Nov 15 2020
Journal Name
Anbar Journal Of Engineering Sciences
Numerical Modelling and Experimental Investigation of Water Distribution in Stratified Soil Under Subsurface Trickle
...Show More Authors

View Publication
Crossref (1)
Crossref
Publication Date
Thu May 18 2023
Journal Name
Journal Of Engineering
Competitive Stripping of Multi-Organic Pollutants from Contaminated Water in Bubble Column Semi-Batch
...Show More Authors

Air  stripping  for  removal  of  Trichloroethylene  (TCE),  Chloroform  (CF)  and  Dichloromethane (DCM) from water were studied in a bubble column (0.073 m inside dia. and 1.08 m height with several sampling ports). The contaminated water was prepared from deionized water and VOCs. The presence of VOCs in feed solution was single, binary or ternary components. They were diluted to the concentrations ranged between 50 mg/l to 250 mg/l. The experiments were carried out in batch experiments which regard the bubble column as stirred tank and only gas was bubbled through stationary liquid. In this case transient measurements of VOC concentration in the liquid phase and the measured concentra

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jun 01 2014
Journal Name
Baghdad Science Journal
Biosorption of Lead, Cadmium and Nickle from Industrial Wast water by Using Dried Macroalgae
...Show More Authors

Biosorpion of lead (Pb), Cadmium (Cd) and Nickl(Ni) by dried biomass of Chara sp. for sample of BMP was used as alternative approach of conventional method. The range of removal percentages was between 92-97%, 70-98.7% and 46.6-96.6% for Pb, Cd and Ni respectively at 3h.Treatment time, with 300-500 mg dried weight from Chara sp. powder at pH 4, with 60 rpm at shaker. FTIR analysis showed the active groups which are responsible for sequestration of heavy metals represented by carboxyl, hydroxyl alkyl, amine and amide. The Biosorption equilibrium experiment for elements showed that the highest sorption percentage for three elements was, Pb 96.6% after 30 minute, for Cd was 100% after 15 minute and 40% to Ni after 75 minute, while the biosorp

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Aug 07 2018
Journal Name
Indian Journal Of Natural Sciences
Evaluation of Drinking Water Quality in Al Wathba Treatment Plant in Baghdad City-Iraq
...Show More Authors

Publication Date
Wed Sep 01 2021
Journal Name
Https://www.researchgate.net/journal/university-of-baghdad-engineering-journal-1726-4073
Evaluation of Drinking Water Quality in Al Wahda Treatment Plant in Baghdad City- Iraq
...Show More Authors

This study aims to evaluate drinking water quality at the Al Wahda plant (WTP) in Baghdad city. A conventional water treatment plant with an average flow rate of 72.82 MLD. Water samples were taken from the influent and effluent of the treatment plant and analyzed for some physicochemical and biological parameters during the period from June to November 2020. The results of the evaluation indicate that treated water has almost the same characteristics as raw water; in other terms, the plant units do not remove pollutants as efficiently as intended. Based on this, the station appears to be nothing more than a series of water passage units. However, apart from Total dissolved solids, the mean values of all parameters in the study were

... Show More
Crossref (1)
Crossref
Publication Date
Wed Dec 12 2018
Journal Name
Iop Conference Series: Materials Science And Engineering
Effect of silicon calcium, boron on Proline and relative water contents in Apple leaves
...Show More Authors

View Publication
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Sun Mar 02 2008
Journal Name
Baghdad Science Journal
Effect of Saline Water and Potassium Fertilizer on Nitrogen Fixation in Pisum sativum L.
...Show More Authors

Field experiment was conducted to test the effect of saline water 2 and7 dSm-1 potassium fertilizer rate 150,300 and 450 kg/donum on nitrogen fixation in Pisum sativum L. nodules. The experiment included anatomy study .Results water salinity ( 2,7 dSm-1) as a main plot and fertilizer rates as a sub plot. Results indicated that irrigation with saline water 7 dSm-¹ caused a significant decrease in N contents especially in the lower parts of the plants. The percentage of the N decreased in lower leaves to (0.01%) under 7dSm-¹ and 300 kg/donum fertilizer; however the percentage increased in the upper leaves to (2.80%) under with 2dSm-¹of irrigation water and 300 kg/ donum fertilizer rate. Fresh weight decreased to 6.26g under 7 dSm

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Sep 01 2021
Journal Name
Journal Of Engineering
Evaluation of Drinking Water Quality in Al Wahda Treatment Plant in Baghdad City- Iraq
...Show More Authors

This study aims to evaluate drinking water quality at the Al Wahda plant (WTP) in Baghdad city. A conventional water treatment plant with an average flow rate of 72.82 MLD. Water samples were taken from the influent and effluent of the treatment plant and analyzed for some physicochemical and biological parameters during the period from June to November 2020. The results of the evaluation indicate that treated water has almost the same characteristics as raw water; in other terms, the plant units do not remove pollutants as efficiently as intended. Based on this, the station appears to be nothing more than a series of water passage units. However, apart from Total dissolved solids, the mean values of all parameters in th

... Show More
View Publication Preview PDF
Crossref (1)
Crossref