Preferred Language
Articles
/
ijp-937
The effect of Cu concentration on some of the electrical properties of CdSe films
...Show More Authors

The CdSe pure films and doping with Cu (0.5, 1.5, 2.5, 4.0wt%) of thickness 0.9μm have been prepared by thermal evaporation technique on glass substrate. Annealing for all the prepared films have been achieved at 523K in vacuum to get good properties of the films. The effect of Cu concentration on some of the electrical properties such as D.C conductivity and Hall effect has been studied.
It has been found that the increase in Cu concentration caused increase in d.c conductivity for pure CdSe 3.75×10-4(Ω.cm)-1 at room temperatures to maximum value of 0.769(Ω.cm)-1 for 4wt%Cu.All films have shown two activation energies, where these value decreases with increasing doping ratio. The maximum value of activation energy was (0.319)eV for pure CdSe film in thermal range (293-363)K. Hall effect results has shown that the sample of pure CdSe film were n-type, while it is p-type for doping films. Also the charge carrier concentration decreases with increasing Cu concentration, and it varies between 2.1×1017 cm-3 for pure films, and 5×1016cm-3 for doping films with 4wt%Cu. The Hall mobility at laboratory temperature has been calculated, and it is increased exponentially from 0.012cm2/V.sec for the pure film to 88.435 cm2/V.sec for doped films with 4wt%Cu. The drift velocity of these films increases with increasing doping concentration.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Oct 26 2021
Journal Name
Periodicals Of Engineering And Natural Sciences (pen)
Achieving urban sustainability by revitalizing the performance of Islamic geometric pattern on residential façades
...Show More Authors

View Publication
Scopus (3)
Scopus Crossref
Publication Date
Tue Sep 19 2017
Journal Name
Journal Of Engineering
Fire Flame Influence on the Behavior of reinforced Concrete Beams Affected by Repeated Load
...Show More Authors

The influence and hazard of fire flame are one of the most important parameters that affecting the durability and strength of structural members. This research studied the influence of fire flame on the behavior of reinforced concrete beams affected by repeated load. Nine self- compacted reinforced concrete beams were castellated, all have the same geometric layout (0.15x0.15x1.00) m, reinforcement details and compressive strength (50 Mpa).

To estimate the effect of fire flame disaster, four temperatures were adopted (200, 300, 400 and 500) oC and two method of cooling were used (graduated and sudden). In the first cooling method, graduated, the tested beams were leaved to cool in air while in the seco

... Show More
View Publication Preview PDF
Publication Date
Wed Jan 08 2020
Journal Name
International Journal Of Advanced Science And Technology
The local stability of an eco-epidemiological model involving a harvesting on predator population
...Show More Authors

In this paper a prey - predator model with harvesting on predator species with infectious disease in prey population only has been proposed and analyzed. Further, in this model, Holling type-IV functional response for the predation of susceptible prey and Lotka-Volterra functional response for the predation of infected prey as well as linear incidence rate for describing the transition of disease are used. Our aim is to study the effect of harvesting and disease on the dynamics of this model.

View Publication
Scopus (2)
Scopus
Publication Date
Fri Sep 01 2017
Journal Name
Journal Of Engineering
Fire Flame Influence on the Behavior of reinforced Concrete Beams Affected by Repeated Load
...Show More Authors

The influence and hazard of fire flame are one of the most important parameters that affecting the durability and strength of structural members. This research studied the influence of fire flame on the behavior of reinforced concrete beams affected by repeated load. Nine self- compacted reinforced concrete beams were castellated, all have the same geometric layout (0.15x0.15x1.00) m, reinforcement details and compressive strength (50 Mpa). To estimate the effect of fire flame disaster, four temperatures were adopted (200, 300, 400 and 500) oC and two method of cooling were used (graduated and sudden). In the first cooling method, graduated, the tested beams were leaved to cool in air while in the second method, sudden, water splash was use

... Show More
Publication Date
Sat Jan 01 2022
Journal Name
Materials Today: Proceedings
Evaluating the individual, dual usage of (TGP) and (SF) additives on improving gypsum characteristics
...Show More Authors

View Publication
Scopus (8)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Wed Jul 01 2020
Journal Name
Iop Conference Series: Materials Science And Engineering
Predicting the future growth depending on GIS and IDRISI program, city of Najaf-Iraq
...Show More Authors
Abstract<p>This study aims to employ modern spatial simulation models to predict the future growth of Al-Najaf city for the year 2036 by studying the change in land use for the time period (1986-2016) because of its importance in shaping future policy for the planning process and decision-making process and ensuring a sustainable urban future, using Geographical information software programs and remote sensing (GIS, IDRISI Selva) as they are appropriate tools for exploring spatial temporal changes from the local level to the global scale. The application of the Markov chain model, which is a popular model that calculates the probability of future change based on the past, and the Cellular Automa</p> ... Show More
View Publication Preview PDF
Scopus (6)
Crossref (7)
Scopus Crossref
Publication Date
Sat Dec 01 2018
Journal Name
Proceedings Of International Structural Engineering And Construction
ON THE REDUCTION OF PRESTRESSING FORCE NEAR SUPPORTS IN PARTIALLY PRESTRESSED CONCRETE FLEXURAL MEMBERS
...Show More Authors

Straight tendons in pretensioned members can cause high-tensile stresses in the concrete extreme fibers at end sections because of the absence of the bending stresses due to self-weight and superimposed loads and the dominance of the moment due to prestressing force alone. Accordingly, the concrete tensile stresses at the ends of a member prestressed with straight tendons may limit the service load capacity of the member. It is therefore important to establish limiting zone in the concrete section within which the prestressing force can be applied without causing tension in the extreme concrete fibers. Two practical methods are available to reduce the stresses at the end sections due to the prestressing force. The first method based

... Show More
View Publication
Crossref
Publication Date
Mon Nov 06 2023
Journal Name
Chemical And Process Engineering
Relative wettability measurement of porous diffuser and its impact on the generated bubble size
...Show More Authors

View Publication
Scopus (3)
Scopus Clarivate Crossref
Publication Date
Mon Apr 01 2019
Journal Name
Biochemical & Cellular Archives
The impact of follicular fluid growth differentiation factor 8 levels on IVF /ICSI outcomes
...Show More Authors

Clinical index is needed to predict the outcome of pregnancy after in vitro fertilization/intracytoplasmic sperm injection-embryo transfer (IVF/ICSI-ET) for infertile patients. Growth differentiation factor-8 (GDF-8), also known as myostatin, is one of transforming growth factor-â superfamily localized in antral follicles in normal and PCOS ovaries but its function in female reproductive system is still unknown. Aim of the study is to assess the correlation between levels of GDF8 in follicular fluid (FF) with outcomes of in vitro fertilization (IVF/ICSI) in women with and without PCOS. A prospective case control study was performed enrolling (40) patients with PCOS and (40) non-PCOS women (male infertility) undergoing IVF/ICSI. The collect

... Show More
Scopus (3)
Scopus
Publication Date
Sun Jan 01 2023
Journal Name
Corporate Governance And Organizational Behavior Review
Impact of the electronic internal auditing based on IT governance to reduce auditing risk
...Show More Authors

This paper analysed the effect of electronic internal auditing (EIA) based on the Control Objectives for Information and Related Technologies (COBIT) framework. Organisations must implement an up-to-date accounting information system (AIS) capable of meeting their auditing requirements. Electronic audit risk (compliance assessment, control assurance, and risk assessment) is a development by Weidenmier and Ramamoorti (2006) to improve AIS. In order to fulfil the study’s objectives, a questionnaire was prepared and distributed to a sample comprising 120 employees. The employees were financial managers, internal auditors, and workers involved in the company’s information security departments in the General Company for Electricity D

... Show More
View Publication
Scopus (32)
Crossref (13)
Scopus Crossref