Preferred Language
Articles
/
ijp-923
CuInS2 Ternary Compound as Absorption Layer for Solar Cell Fabrication
...Show More Authors

Copper indium disulphide, CuInS2, is a promising absorber material for thin film photovoltaic which has recently attracted considerable attention due to its suitability to reach high efficiency solar cells by using low cost techniques. In this work CuInS2 thin films have been deposited by chemical spray pyrolysis onto glass substrates at ambient atmosphere, using different [Cu]/[In] ratio in the aqueous solutions at substrate temperature 3000C
and different annealing temperatures . Structural and optical properties of CIS films were analyzed by X-ray diffraction, and optical spectroscopy. Sprayed CIS films are polycrystalline with a chalcopyrite structure with a preferential orientation along the 112 direction and no remains of oxides in higher ratio were found after spraying in suitable conditions. X-ray microanalysis shows that a chemical composition near to stoichiometry can be obtained. An optical properties showed this material have a direct band gap and the energy band in the range of about 1.4 -1.61 eV at different ratio was found for sprayed CIS thin films.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Oct 29 2020
Journal Name
The 11th International Renewable Energy Congress (irec 2020)
Thermal efficiency Optimization of the evacuated tube solar water heater system by using mirror flat reflector
...Show More Authors

In this paper a comparison of the experimental of evacuated tube solar water heater systems with and without mirror flat reflector. The aim of using the reflector to improve thermal efficiency, and the data gathered which are (temperature, solar irradiation and time) for three days were compared. the results from compared data the temperature lower increase in evacuated tube solar water heater system without reflector than the temperature increase in evacuated tube solar water heater system with reflector .The results show (53, 39, 35) % for three days respectively that the evacuated tube solar water heater system with reflector has higher thermal efficiencies than the results (47, 28, 30) % for three days respectively thermal efficiencies

... Show More
View Publication
Crossref
Publication Date
Sun Dec 20 2020
Journal Name
Al-mustansiriyah Journal Of Science
Seasonal Variations of the Optimum Reliable Frequencies During Maximum and Minimum Periods of Solar Cycle 24
...Show More Authors

In this research, the seasonal Optimal Reliable Frequency (ORF) variations between different transmitter/receiver stations have been determined. Mosul, Baghdad, and Basra have been chosen as tested transmitting stations that located in the northern, center, and southern of Iraqi zone. In this research, the minimum and maximum years (2009 and 2014) of solar cycle 24 have been chosen to examine the effect of solar activity on the determined seasonal ORF parameter. Mathematical model has been proposed which leads to generate the Optimal Reliable Frequency that can maintain the seasonal connection links for different path lengths and bearings. The suggested ORF parameter represented by a different orders polynomial equation. The polynom

... Show More
View Publication
Crossref (1)
Crossref
Publication Date
Sat Apr 01 2023
Journal Name
Heliyon
Application of solar photo-electro-Fenton technology to petroleum refinery wastewater degradation: Optimization of operational parameters
...Show More Authors

View Publication
Scopus (17)
Crossref (14)
Scopus Clarivate Crossref
Publication Date
Thu Oct 01 2009
Journal Name
Iraqi Journal Of Physics
Effect of Glass Inclination of Windows Facing East and West on Solar Radiation Transmittance into Buildings
...Show More Authors

To reduce solar radiation transmittance into buildings through windows facing east or west during summer, a window inclination from vertical position is suggested. The inclination of the window glazing and the rate of unwanted solar radiation during summer can be calculated knowing the dialy inclination of the sun rays. The inclination of window glazing depends on the latitude of the position required. For instance in Baghdad which is at about 33o north latitude a slope of 15o for window glazing is sufficient to prevent about 419 MJ/m2 of total solar radiation energy from penetration during summer for clear glazing of window facing east. This value drops to about 96 MJ/m2 during winter. Therefore the ratio between the energy saved for co

... Show More
View Publication Preview PDF
Publication Date
Mon Aug 27 2018
Journal Name
Al-khwarizmi Engineering Journal
Efficiency Enhancement of a Dual-axis Solar PV Panel Tracker Using Water-Flow Double Glazing Technique
...Show More Authors

The fall angle of sun rays on the surface of a photovoltaic PV panel and its temperature is negatively affecting the panel electrical energy produced and efficiency. The fall angle problem was commonly solved by using a dual-axis solar tracker that continually maintains the panel orthogonally positioning to the sun rays all day long. This leads to maximum absorption for solar radiation necessary to produce maximum amount of energy and maintain high level of electrical efficiency. To solve the PV panel temperature problem, a Water-Flow Double Glazing WFDG technique has been introduced as a new cooling tool to reduce the panel temperature. In this paper, an integration design of the water glazing system with a dual-axis tracker has been ac

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Thu Sep 01 2022
Journal Name
Jordan Journal Of Mechanical And Industrial Engineering
Empact of Discrete Multi-arc Rib Roughness on the Effective Efficiency of a Solar Air Heater
...Show More Authors

Artificial roughness on the absorber plate of a Solar Air Heater (SAH) is a popular technique for increasing its effective efficiency. The study investigated the effect of geometrical parameters of discrete multi-arc ribs (DMAR) installed below the SAH absorber plate on the effective efficiency. The effects of major roughness factors, such as number of gaps (Ng = 1-4), rib pitch (p/e = 4-16), rib height (e/D = 0.018-0.045), gab width (wg/e = 0.5-2), angle of attack ( = 30-75), and Reynolds number (Re= 2000-20000) on the performance of a SAH are studied. The performance of the SAH is evaluated using a top-down iterative technique. The results show that as Re rises, SAH-effective DMAR's efficiency first ascends to a specified value o

... Show More
Publication Date
Fri May 01 2015
Journal Name
Journal Of Engineering
Experimental Study of the Thermal Performance of Flat Plate Solar Collectors Array by Different Connection Configurations
...Show More Authors

The current research illustrates experimentally the effect of series and parallel connection (Z-I Configurations) of flat plate water solar collectors array on the thermal performance of closed loop solar heating system. The study includes the effect of changing the water flow rate on the thermal efficiency. The results show that, the collector's efficiency in series connection is higher than the parallel connection within flow rate level less than (100) ℓ/hr. Moreover, the collector efficiency in parallel connection of (I-Configurations) is more than the (Z- Configurations) with increasing the water flow rate .The maximum daily efficiency for parallel (I-Configurations) and (Z- Configurations) are (55%) and (51%) at w

... Show More
View Publication Preview PDF
Publication Date
Tue Feb 13 2018
Journal Name
Journal Of Optics
Solar selective performance of metal nitride/oxynitride based magnetron sputtered thin film coatings: a comprehensive review
...Show More Authors

View Publication
Scopus (30)
Crossref (20)
Scopus Clarivate Crossref
Publication Date
Sun Apr 30 2017
Journal Name
Journal Of Engineering
Biotreatment of Slaughterhouse Wastewater Accompanied with Electrcity Generation and Nutrients Recovery in Microbial Fuel Cell
...Show More Authors

In recent years and decades, there is a great need for developing new alternative energy sources or renewable sustainable energy. On the other hand, new technology approaches are growing . towards benefits from the valuable nutrients in wastewater which are unrecoverable by traditional wastewater treatment processes.  In the current study, a novel integrated system of microbial fuel cell and anoxic bioreactor (MFC-ANB) was designed and constructed to investigate its potential for slaughterhouses wastewater treatment, nitrogen recovery, and power generation. The system consisted of a double-chamber tubular type MFC with biocathode inoculated with freshly collected activated sludge. The MFC-ANB system was continuously fed with real-fi

... Show More
View Publication Preview PDF
Publication Date
Sun Nov 01 2015
Journal Name
Journal Of Natural Science Research
Purification of G-Protein Coupled Receptor from Whole Cell of Local Strain of Saccharomyces cerevisiae
...Show More Authors

The aim of study To purify GPCR from a local strain of S. cerevisiae using Ion exchange and gel filtration chromatography techniques , by packing materials for columns which will be chosen of low cost comparing to the already used in published researches, which depend on the costly affinity chromatography and other expensive methods of purification. Local strain of S. cerevisiae chosen for extraction and purification of G-protein coupled receptor (GPCR) .The strains were obtained from biology department in Al- Mosul University, Iraq. The isolated colony was activated on Yeast Extract Pepton Dextrose Broth (YEPDB) and incubated at 30 C˚ for 24 h .Loop fully of the yeast culture was transferred to (10ml) of yeast extract peptone glucose

... Show More
View Publication