Preferred Language
Articles
/
ijp-88
Estimation of kidney tumor volume in CT images using medical image segmentation techniques
...Show More Authors

Kidney tumors are of different types having different characteristics and also remain challenging in the field of biomedicine. It becomes very important to detect the tumor and classify it at the early stage so that appropriate treatment can be planned. Accurate estimation of kidney tumor volume is essential for clinical diagnoses and therapeutic decisions related to renal diseases. The main objective of this research is to use the Computer-Aided Diagnosis (CAD) algorithms to help the early detection of kidney tumors that addresses the challenges of accurate kidney tumor volume estimation caused by extensive variations in kidney shape, size and orientation across subjects.
In this paper, have tried to implement an automated segmentation method of gray level CT images. The segmentation process is performed by using the Fuzzy C-Means (FCM) clustering method to detect and segment kidney CT images for the kidney region. The propose method is started with pre-processing of the kidney CT image to separate the kidney from the abdomen CT and to enhance its contrast and removing the undesired noise in order to make the image suitable for further processing. The resulted segmented CT images, then used to extract the tumor region from kidney image defining the tumor volume (size) is not an easy task, because the 2D tumor shape in the CT slices are not regular. To overcome the problem of calculating the area of the convex shape of the hull of the tumor in each slice, we have used the Frustum model for the fragmented data.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Jul 01 2023
Journal Name
International Journal Of Intelligent Engineering And Systems
An Efficient Cryptosystem for Image Using 1D and 2D Logistic Chaotic Maps
...Show More Authors

View Publication Preview PDF
Scopus (4)
Crossref (2)
Scopus Crossref
Publication Date
Sat Jun 01 2024
Journal Name
Journal Of Engineering
Copy Move Image Forgery Detection using Multi-Level Local Binary Pattern Algorithm
...Show More Authors

Digital image manipulation has become increasingly prevalent due to the widespread availability of sophisticated image editing tools. In copy-move forgery, a portion of an image is copied and pasted into another area within the same image. The proposed methodology begins with extracting the image's Local Binary Pattern (LBP) algorithm features. Two main statistical functions, Stander Deviation (STD) and Angler Second Moment (ASM), are computed for each LBP feature, capturing additional statistical information about the local textures. Next, a multi-level LBP feature selection is applied to select the most relevant features. This process involves performing LBP computation at multiple scales or levels, capturing textures at different

... Show More
Crossref
Publication Date
Wed Sep 01 2021
Journal Name
Baghdad Science Journal
An Efficient Image Encryption Using a Dynamic, Nonlinear and Secret Diffusion Scheme
...Show More Authors

The growing use of tele

This paper presents a new secret diffusion scheme called Round Key Permutation (RKP) based on the nonlinear, dynamic and pseudorandom permutation for encrypting images by block, since images are considered particular data because of their size and their information, which are two-dimensional nature and characterized by high redundancy and strong correlation. Firstly, the permutation table is calculated according to the master key and sub-keys. Secondly, scrambling pixels for each block to be encrypted will be done according the permutation table. Thereafter the AES encryption algorithm is used in the proposed cryptosystem by replacing the linear permutation of ShiftRows step with the nonlinear and secret pe

... Show More
View Publication Preview PDF
Scopus (3)
Scopus Clarivate Crossref
Publication Date
Thu Apr 01 2021
Journal Name
Biochemical And Cellular Archives
STUDY OF LYSYL OXIDASE-1 AND KIDNEY FUNCTION IN SERA OF IRAQI PATIENTS WITH DIABETIC NEPHROPATHY
...Show More Authors

This study aimed to compare lysyl oxidase-1 level in diabetic patients with and without renal dysfunction, that LOX-1 may be an indicator for the early stage of diabetic nephropathy (DN). In addition to finding it is a relationship with kidney functions in Iraqi diabetic patients with and without renal dysfunction. Blood was obtained from 25 healthy individuals as a control group (G1), 25 diabetic patients with renal dysfunction, and 25 diabetic patients without renal dysfunction. Age range 40-60 years for all subjects. BMI (25-27) Kg/m2 . The serum was used for the analysis of LOX-1, FBG, urea, creatinine and uric acid. Whole blood is used for the determination of HbA1C. Results of FBG and HbA1C revealed a significant increase in G2 and G

... Show More
Publication Date
Thu Jun 01 2023
Journal Name
Baghdad Science Journal
Biochemical Study on the Impact of Radiation-induced Oxidative Stress on Radiographers in the X-ray and CT-scan Departments
...Show More Authors

The consequences of ionizing radiation-induced oxidative stress on radiographers in X-ray and CT-scan departments utilizing several biochemical were analyzed. The study found highly considerable discrepancies in the interplay between radiation levels and gender in terms of mean Malondialdehyde (MAD), Vitamin D3 (Vit.D3), Triiodothyronine (T3), Thyroxine (T4), and High-Density Lipoprotein (HDL), but not Thyroid Stimulating Hormone (TSH), cholesterol, triglyceride (TG) and Low-Density Lipoprotein (LDL). The findings indicated that malondialdehyde is a useful biomarker for assessing oxidative stress in radiographers with exposure to ionizing radiation.

View Publication Preview PDF
Scopus (2)
Scopus Crossref
Publication Date
Sat Dec 30 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Using Image Processing of A Fabry -Perot Interferometer to Determine the Defects of Leneses by Using He-Ne Laser
...Show More Authors

A design of a Fabry -Perot  interferometer system was constructed

to determine the precise value of the wavelength which is required in spectml studies depending on varying medium pressure where the refractive  index  was a  function  of  pressure  at  a  constant  distance between  the  two  mirrors by  using a Hc-Ne  laser (632.8)  tun as  a coherent source .

The (fmee) (t) and the coefficient of finesses (F) and the visbility

of the fringes (V) has been calculated  . Image processing \\•as used and   its  result   can   be   relied   on   verifying&nbsp

... Show More
View Publication Preview PDF
Publication Date
Fri Jul 01 2022
Journal Name
Eurasian Chemical Communications
Assessment of hypoxemia status by measuring serum level of hypoxia inducible factor 1 alpha in relation to tumor suppression protein p53, estradiol and tumor proliferation markers of breast cancer in Thi-Qar province/Iraq
...Show More Authors

Scopus (9)
Scopus Clarivate
Publication Date
Sun Dec 16 2018
Journal Name
Al-academy
The Eloquence of the Sound in the Production of Mental Image in the Feature Film
...Show More Authors

The ideas and information obtained by the viewer in the cinema have always been the source of the visual image, but that doesn’t negate the fact that the mental image can produce a lot of the information and ideas in the cinematic art and the most important means to achieve this mental image in the film is the eloquent cinematic sound. This research is conducted to show this important and effective contribution of the sound in the production of the mental image. Hence the importance of this research is in that it addresses an important issue which is the eloquent performance of the sound and its role in the production of the mental image inside the space of the feature film. This research concerns those working the field of cinema and

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Nov 01 2012
Journal Name
Journal Of Computer Science
VOICE ACTIVATION VISUALIZATION FOR ECHOCARDIOGRAPH AND 3D ANGIOGRAPHIC IMAGES IN SURGERY
...Show More Authors

In some cases, surgeons need to navigate through the computer system for reconfirmation patients’ details and unfortunately surgeons unable to manage both computer system and operation at the same time. In this paper we propose a solution for this problem especially designed for heart surgeon, by introducing voice activation system with 3D visualization of Angiographic images, 2D visualization of Echocardiography processed video and selected patient’s details. In this study, the processing, approximation of the 3D angiography and the visualization of the 2D echocardiography video with voice recognition control are the most challenging work. The work involve with predicting 3D coronary three from 2D angiography image and also image enhan

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Crossref
Publication Date
Sun Jun 01 2014
Journal Name
Journal Of Economics And Administrative Sciences
Estimation the reliability function of multi state system by using Direct Partial Logic Derivative
...Show More Authors

In this research is estimated the function of reliability dynamic of multi state systems  and their compounds and for three types of systems (serial, parallel, 2-out-of-3) and about two states (Failure and repair) depending on calculating the structur function allow to describing the behavior of

... Show More
View Publication Preview PDF
Crossref