Kidney tumors are of different types having different characteristics and also remain challenging in the field of biomedicine. It becomes very important to detect the tumor and classify it at the early stage so that appropriate treatment can be planned. Accurate estimation of kidney tumor volume is essential for clinical diagnoses and therapeutic decisions related to renal diseases. The main objective of this research is to use the Computer-Aided Diagnosis (CAD) algorithms to help the early detection of kidney tumors that addresses the challenges of accurate kidney tumor volume estimation caused by extensive variations in kidney shape, size and orientation across subjects.
In this paper, have tried to implement an automated segmentation method of gray level CT images. The segmentation process is performed by using the Fuzzy C-Means (FCM) clustering method to detect and segment kidney CT images for the kidney region. The propose method is started with pre-processing of the kidney CT image to separate the kidney from the abdomen CT and to enhance its contrast and removing the undesired noise in order to make the image suitable for further processing. The resulted segmented CT images, then used to extract the tumor region from kidney image defining the tumor volume (size) is not an easy task, because the 2D tumor shape in the CT slices are not regular. To overcome the problem of calculating the area of the convex shape of the hull of the tumor in each slice, we have used the Frustum model for the fragmented data.
Heat transfer around a flat plate fin integrated with piezoelectric actuator used as oscillated fin in laminar flow has been studied experimentally utilizing thermal image camera. This study is performed
for fixed and oscillated single and triple fins. Different substrate-fin models have been tested, using fins of (35mm and 50mm) height, two sets of triple fins of (3mm and 6mm) spacing and three frequencies
applied to piezoelectric actuator (5, 30 and 50HZ). All tests are carried out for (0.5 m/s and 3m/s) in subsonic open type wind tunnel to evaluate temperature distribution, local and average Nusselt number (Nu) along the fin. It is observed, that the heat transfer enhancement with oscillation is significant compared to without o
The present study aimed to investigate the histological changes of heart, lung, liver and kidney which caused by different concentrations (10, 20 and 40 mg/kg) of Ivabradine. Results of the study revealed some histological changes represented by aggregation of the lymphocytes around respiratory bronchioles of the lung. In the liver, the drug caused hepatocyte necrosis and infiltration of the lymphocytes. In Kidney, there are no histopathological modifications in the tissue after the animals treated with 10 mg\kg of Ivabradine. When the animals treated with Ivabradine drug at 20mg/kg of bw, dose showed vascular congestion between myocardial fibers of heart. Emphysematous c
... Show MoreThe present study aims to describe the histological structure of kidney of, (Herpestes javanicus ) that inhabits Iraqi lands. Transverse sections of kidney stained with hematoxylin and eosin showed two distinct regions, the outer thin darkly stained cortex and inner thick lightly stained medulla, which further subdivided into external and internal medullary zones linked with one conical renal papilla. The lateral margin of the outer medullary tissue forms a secondary renal pyramid with a specialized fornix. All the nephrons in the kidney start with the renal corpuscle [Malpighian], which is formed from two distinct parts, these are a centrally located glomerulus, which represented by a tuft of blood capillaries and an outer Bowman’s capsu
... Show MoreIncreased interest in the subject of the image because of its great and growing link to the life of the individual and society and its impact on the overall political, economic and cultural conditions. This interest is no longer confined to the images of people or institutions, but has become beyond that to the images of countries and peoples and the impact on bilateral relations between them,
However, we find that the image of the Iraqi abroad remained vague and has not been scientifically recognized and the most that we can generalize are the features of the image of Arabs and Muslims abroad; and assume that the image of the Iraqi applies to them as the Iraqi is in the end an Arab or Muslim.
Based on this, the research
... Show MoreThis study was conducted to determine the Immuno – globulins and complements quantitatively. The result revealed that the concentration of Immunoglobulin M(IgM) was increased significantly in patient group comparing with control group . The concentration of complement protein C4 was increased significantly in patient group comparing with control group.IgG of Candida albicans was detected by using ELISA Technique, the result indicated also that this antibody was found in 628% of the women who infected with Vulvovaginal Candidiasis. The sensitivity and specificity of the test were 63% and 89% respectively.
The aims of the lecture should be clearly defmed. These will help to define the teaching methods and the structure. If, for example, the purpose of the lecture is to introduce new knowledge and concepts, then a classic lecture structure might be most appropriate. On the other hand, if the purpose is to make the students aware of different approaches to a particular clinical problem, a problem oriented design in which alternative approaches are presented and discussed might be a more appropriate fonnat.
Lectures are still a common teaching methOd in both undergraduate and postgraduak medical education. Properly done, the lectwe is a creative and personal work by the teachll:l modeled upon his intellectual scaffolding. Few other fonns o
Steganography art is a technique for hiding information where the unsuspicious cover signal carrying the secret information. Good steganography technique must be includes the important criterions robustness, security, imperceptibility and capacity. The improving each one of these criterions is affects on the others, because of these criterions are overlapped each other. In this work, a good high capacity audio steganography safely method has been proposed based on LSB random replacing of encrypted cover with encrypted message bits at random positions. The research also included a capacity studying for the audio file, speech or music, by safely manner to carrying secret images, so it is difficult for unauthorized persons to suspect
... Show More