Preferred Language
Articles
/
ijp-868
Analysis of Initiation and Growth of Plasma Channels Within Non-Mixed Dielectric Liquids
...Show More Authors

Pre-breakdown phenomenon was investigated within the two, non-mixed dielectric liquids; transformation oil and cresol. Finite element technique was used to follow the initiation and growth of plasma channels (streamer discharge) within pin-plane configuration. That was done for different spacing between the pin-electrode and the liquid-liquid interface. Streamer growth model assumed that, the streamer initiation occurs at the region of the highest value of electric field. Our study shows that the streamer initiates at the tip of the pin and growths toward the other electrode. The study shows, too, that the streamer path controlled by the difference of permittivity of the two liquids and spacing distance of the liquid-liquid interface from the tip of the pin electrode. This type of studies is very important to give a good approximation for the high voltage equipments designing

View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Dec 11 2018
Journal Name
Baghdad Science Journal
Thermoluminescence dosimetry of mixed neutron – gamma fields
...Show More Authors

The method of measurement dosimetry in neutron – gamma field by using CaSo4 : Dy (PTFE) disc which has a diameter of 1.3mm and thickness of 0.2mm and using hydrogenated material as a converters of neutron to recoil protons (n-p) reaction, the discs were irradiated by neutron source (241Am-Be) with flux of 4.5?105 n/cm2s for different time to obtain different dose. The TL signals, which we have been obtained by using the converters, are increases to 71%. So we can resolve the neutron and gamma in mixed field.

View Publication Preview PDF
Crossref
Publication Date
Fri Jun 25 2021
Journal Name
International Journal Of Drug Delivery Technology
Mixed Ligand Complexes of Trimethoprim: A Review
...Show More Authors

In this research, we highlight the most important research related to the mixed ligand complexes of the drug trimethoprim (TMP), and for the past 7 years where this drug has been used as a chelating ligand and gives stability to the complexes with ions of metal elements where these complexes, prepared and diagnosed, and for some research the bacterial activity was studied against different types of bacteria

View Publication
Scopus (1)
Scopus
Publication Date
Wed Jun 02 2021
Journal Name
International Journal Of Drug Delivery Technology
Mixed Ligand Complexes of Trimethoprim: A Review
...Show More Authors

In this research, we highlight the most important research related to the mixed ligand complexes of the drug trimethoprim (TMP), and for the past 7 years where this drug has been used as a chelating ligand and gives stability to the complexes with ions of metal elements where these complexes, prepared and diagnosed, and for some research the bacterial activity was studied against different types of bacteria.

Preview PDF
Publication Date
Mon Jun 04 2018
Journal Name
Baghdad Science Journal
The Effect of Gas Flow on Plasma Parameters Induced by Microwave
...Show More Authors

In this paper, construction microwaves induced plasma jet(MIPJ) system. This system was used to produce a non-thermal plasma jet at atmospheric pressure, at standard frequency of 2.45 GHz and microwave power of 800 W. The working gas Argon (Ar) was supplied to flow through the torch with adjustable flow rate by using flow meter, to diagnose microwave plasma optical emission spectroscopy(OES) was used to measure the important plasma parameters such as electron temperature (Te), residence time (Rt), plasma frequency (?pe), collisional skin depth (?), plasma conductivity (?dc), Debye length(?D). Also, the density of the plasma electron is calculated with the use of Stark broadened profiles

View Publication Preview PDF
Scopus (19)
Crossref (7)
Scopus Clarivate Crossref
Publication Date
Mon Nov 01 2010
Journal Name
Iraqi Journal Of Physics
Streams and plasma parameters experimental studies in He-CO gas mixtures
...Show More Authors

DC glow discharges were generated between a thin cylindrical anode and a flat cathode, streamers are thought to propagate by photo-ionization; the parameters of photo-ionization depend on the He: CO ratio. Therefore we study streamers in He ( 90%, 80% and 70% ) with (10%, 20% and 30%) CO respectively. The streamer diameter is essentially the change by increase for similar voltage and pressure in all He-CO mixtures.

View Publication Preview PDF
Publication Date
Wed Jul 01 2015
Journal Name
Journal Of Engineering
Effect of Plasma Shot Peening on Mechanical Properties and Fatigue life of AL-Alloys 2024-T3
...Show More Authors

An Investigation of estimated Mechanical Properties of AL-Alloys 2024-T3, which is the most commonly used in industrial applications, been established experimentally. A new novel Plasma Peening techniques had applied for the whole surfaces of the material by CNC-Plasma machine for 48 specimen, and then a new investigation were toke over to figure the amount of change in mechanical properties and estimated fatigue life. It found that improvement was showing a nonlinear behavior according to peening duration time, speed, peening distance, peening number, and amount of effected power on the depth of the material thickness. The major improvement was at medium speed long duration time normal peening distance. Which shows up t

... Show More
View Publication Preview PDF
Publication Date
Sun Mar 20 2016
Journal Name
Al-academy
The Floors and transparent role in the design studios satellite channels: وسام صالح حمد
...Show More Authors

The search (floors and transparent role in the design studios satellite channels) and presented as a study-oriented, and the research aims to identify the role of flooring transparent spaces studios satellite channels and side performative and aesthetic, and formulas design to highlight the role floors transparent spaces studios satellite channels. And highlight the importance of research, particularly in its contribution to the clarification of the concept of the relationship between transparency and performing aesthetic treatments for floors by clarifying its role in the designs of the internal spaces of the studios, as well as his contribution to the founding of the theory of looking at the base of such concepts. To achieve the object

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Sep 27 2019
Journal Name
Iop Conf. Series: Journal Of Physics: Conf. Series
Preparation and Spectroscopic Characterization of Chromium(III) and Iron(III) Mixed Ligand Complexes
...Show More Authors

.Curcumin (Cur) and L phenylalanine (Phy) compounds were used to prepare two mixed ligand complexes with Cr (III) and Fe (III) ions. The synthesized complexes are characterized by using conductivity measurement and different spectral methods like FT-IR and UV- Vis .Molar conductance and analytical studies confirmed that the complexes exhibit octahedral geometry., suggest that the complexes are formed in 1: 1 :2 [ L : Metal : 2phe ] ratio and they proposed to have the general formulae [M(Cur)(phe)2] Cl (M= Cr (III) and Fe (III) The compound dyeing method was studied and applied to acrylic fabric.The antibacterial activity of curcumin, phenylalanine and their mixed ligand complexes were examined on pathogenic bacterial strains and showed good

... Show More
Preview PDF
Publication Date
Sat Jul 01 2023
Journal Name
Journal Of Physics: Conference Series
Mixed Ligand Complexes of Schiff Base and Nicotinamide: Synthesis, Characterization and Antimicrobial Activities
...Show More Authors

A new Schiff base of HL has been synthesized from amoxicillin drug and 4- Chlorobenzophenone. Cr (III), Fe (III), Co (II), Ni (II), Cu (II), Cd (II) and Hg (II) mixed ligands complexes of Schiff base and Nicotinamide. Diagnosis of synthesis ligand and its complexes are done by 1HNMR, 13CNMR and thermal analysis for HL ligand, FTIR, UV-visible, molar conductance, CHN analysis, magnetic susceptility and atomic absorption. Octahedral geometries have been suggested for all complexes. All compounds under study were tested antimicrobial activity against four type of bacteria such as Pseudomonas aeruginosa, Escherichia coli, Staphylococcus aureus Bacillis subtilis in nutrient agar.

Preview PDF
Scopus (2)
Scopus
Publication Date
Mon Feb 04 2019
Journal Name
Iraqi Journal Of Physics
Estimation of electron temperature for SiO2 plasma induced by laser
...Show More Authors

In this work; Silicon dioxide (SiO2) were fabricated by pulsed
laser ablation (PLA). The electron temperature was calculated by
reading the data of I-V curve of Langmuir probe which was
employed as a diagnostic technique for measuring plasma properties.
Pulsed Nd:YA Glaser was used for measuring the electron
temperature of SiO2 plasma plume under vacuum environment with
varying both pressure and axial distance from the target surface. The
electron temperature has been measured experimentally and the
effects of each of pressure and Langmuir probe distance from the
target were studied. An inverse relationship between electron
temperature and both pressure and axial distance was observed.

View Publication Preview PDF
Crossref