CR-39 is a solid state nuclear track detector (SSNTD) that has been used in many research areas. In spite of the assumption that the CR-39 detectors are insensitive to beta and gamma rays, irradiation with these rays can have significant effects on the detector properties. In this study, beta and gamma rays mass attenuation coefficients μ/ρ (cm2 g-1) for the CR-39 detector have been measured using NaI(Tl) scintillation spectrometer along with a standard geometrical arrangement in the energy region of (0.546-2.274) MeV beta rays and standard gamma sources having energy 0.356, 0.5697, 0.6617 and 1.063 MeV. The total atomic cross-section (σtot), total electronic cross-section (σT E) and the effective atomic number (Zeff) of gamma rays at energy of 1keV- 105 MeV have been also calculated using the Winxcom and MathCAD programs. The data base and the calculated results were compared with the measured experimental values. It has been found that the mass attenuation coefficients vary with the type of interaction of radiation, photoelectric interaction gives dominant contribution to the total mass attenuation coefficients for CR-39 detectors. Further, the Zeff changes with change of energy.
New complexes of the some trivalent transition metal ions of the uracil such as [M(Ura)3Cl3] and mixed ligand metal complexes with uracil and oxalic acid [M(Ura)2(OA)(OH2)Cl].H2O type, where (Ura)=Uracil, (OA= Oxalic acid dihydrate, (M= Cr+3 and Fe+3) were synthesized and characterized by the elemental analysis, FT.IR, electronic spectra, mass spectra and magnetic susceptibility as well as the conductivity measurements. Six–coordinated metal complexes were suggested for the isolated complexes of Cr+3 and Fe+3 with molecular formulas dependent on the nature of uracil and oxalic acid present. The proposed molecular structure for all complexes with their ions is octahedral geometries. The antibacterial efficiency was tested of metal salts, l
... Show MoreThis paper presents the Taguchi approach for optimization of hardness for shape memory alloy (Cu-Al-Ni) . The influence of powder metallurgy parameters on hardness has been investigated. Taguchi technique and ANOVA were used for analysis. Nine experimental runs based on Taguchi’s L9 orthogonal array were performed (OA),for two parameters was study (Pressure and sintering temperature) for three different levels (300 ,500 and 700) MPa ,(700 ,800 and 900)oC respectively . Main effect, signal-to-noise (S/N) ratio was study, and analysis of variance (ANOVA) using to investigate the micro-hardness characteristics of the shape memory alloy .after application the result of study shown the hei
... Show MoreThe research aims to evaluate the radioactivity in elected samples of cereals and legume which are wide human consumption in Iraq using Nuclear Track Detectors (NTDs) model CN-85.
The samples were prepared scientifically according to references in this field. After 150 days of exposure, the detector were collected and chemically treated according to scientific sources (etching chemical), nuclear effects have been calculated using the optical microscope.
Radon (222Rn) concentration and uranium (238U) were calculated in unit Bq/m3 and (ppm), the results indicate that the highest concentration of radon and uranium was in yellow corn where the concentration of radon was 137.17×102 Bq/m3 and uranium concentration 2.63 (ppm). The lowest
In the current work various types of epoxy composites were added to concrete to enhance its effectiveness as a gamma- ray shield. Four epoxy samples of (E/clay/B4C) S1, (E/Mag/B4C) S2, (EPIL) S3 and (Ep) S4 were used in a comparative study of gamma radiation attenuation properties of these shields that calculating using Mont Carlo code (MCNP-5). Adopting Win X-com software and Artificial Neural Network (ANN), µ/ρ revealed great compliance with MCNP-5. By applying (µ/ρ) output for gamma at different energies, HVL, TVL and MFP have been also estimated. ANN technique was simulated to estimate (µ/ρ) and dose rates. According to the results, µ/ρ of all epoxy samples scored higher than standard concrete. Both S2 and S3 samples having h
... Show MoreKey components estimated in Acol total plant leaves and the results were as follows plant Acol humidity 72%
Each Intensity Modulated Radiation Therapy (IMRT) plan needs to be tested and verified before any treatment to check its quality. Octavius 4D-1500 phantom detector is a modern and qualified device for quality assurance procedure. This study aims to compare the common dosimetric criteria 3%/3 mm with 2%/2 mm for H&N plans for the IMRT technique. Twenty-five patients with head and neck (H&N) tumor were with 6MV x-ray photon beam using Monaco 5.1 treatment planning software and exported to Elekta synergy linear accelerator then tested for pretreatment verification study using Octavius 4D-1500 phantom detector. The difference between planned and measured dose were assessed by using local and global gamma index (GI) analysis method at
... Show MoreA total global dominator coloring of a graph is a proper vertex coloring of with respect to which every vertex in dominates a color class, not containing and does not dominate another color class. The minimum number of colors required in such a coloring of is called the total global dominator chromatic number, denoted by . In this paper, the total global dominator chromatic number of trees and unicyclic graphs are explored.
The aim of this study is to evaluate the levels of trace elements Magnesium (Mg), Zinc (Zn), Copper (Cu), and Selenium (Se) in blood sera of asthmatic patients by Atomic Absorption Spectrophotometry (AAS). The concentrations of Mg, Cu, and Zn have been determined by Flame Atomic Absorption spectrophotometry (FAAS), and Se with flameless Graphite Furnace Atomic Absorption Spectrophotometry (GFAAS). The study involves (55) asthmatic patients as study group and (28) subjects as control from both genders. Serum levels of Mg, Cu, and Se were significantly higher (p<0.001 for all) in patients when compared with healthy subjects, while Zn level was relatively significant (p<0.05). Our observations confirm the efficacy and applicability of (AAS) in
... Show MoreCharge multipole Coulomb scattering form factors in 48Ca nucleus have been reproduced utilizing the theory of nuclear shell. The efficient two-body nuclear potential fpbm is considered to construct the-spin orbit term LS vectors with Harmonic Oscillator HO potential as a wave function of single particle in Fp shell. Discarded spaces ( core + higher configuration) are taken into account through the Core polarization effect by model space with accurate two-body potential of Gogny to interact the LS operating particles with the discarded space pair ( particle-hole) with energy of excitation equal to 2ћω. Gogny interaction has been selected as it had succeeded in nuclear shell theory. The computed results were compared with th
... Show MoreScorpions and spiders belong to the class Arachnida in phylum Arthropoda. Scorpions are easily distinguished by median eyes on obvious the center of the carapace and have one pair, and lateral eyes have 2-8 in some species. Scorpions do not have good eyesight so the median eyes have always been simple and they are more sensitive than the lateral pairs. They have anterior median eyes (AME) with narrow field of view and pairs of lateral eyes (LE) with more sensitivity and response to light. Family Buthidae have 2-6 lateral eyes in Compsobuthus Mesobuthus, Hottentotta, while Vaejovidae, Chactidae and Chaerilidae have 2 pairs of lateral eyes. In addition, 3 pairs are found in Orthochirus and Androctonus. Spiders have six eyes in family Pholicid
... Show More