Preferred Language
Articles
/
ijp-844
Determination of Skip Entry Trajectories for Space Vehicles at Circular and Super Circular Speeds
...Show More Authors

The study of entry and reentry dynamics for space vehicles is very important, particularly for manned vehicles and vehicles which is carry important devices and which can be used again. There are three types for entry dynamic, ballistics entry, glide entry and skip entry. The skip entry is used in this work for describing entry dynamics and determining trajectory. The inertia coordinate system is used to derive equations of motion and determines initial condition for skip entry. The velocity and drag force for entry vehicle, where generate it during entry into earth’s atmosphere are calculated in this work. Also the deceleration during descending and determining entry angles, velocities ratio and altitude ratio have been studied. The circular velocity and super circular velocity are used in this work as initial values. From results we noted the skip entry type has longer flight time compared with other types, and the velocity vehicle is lower at high layer for earth atmosphere, where the density of air is very low. Therefore the skip entry is suitable for space shuttle during entry from space

View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Oct 14 2016
Journal Name
International Journal For Computational Methods In Engineering Science And Mechanics
Simultaneous determination of time-dependent coefficients and heat source
...Show More Authors

View Publication
Scopus (18)
Crossref (15)
Scopus Crossref
Publication Date
Fri Nov 11 2022
Journal Name
Al-nisour Journal For Medical Sciences
Spectrophotometric determination of sulfamethoxazole in pure and pharmaceutical formulations
...Show More Authors

New, easy, simple, and fast spectral method for estimation of sulfamethoxazole (SMZ) in pure and pharmaceutical forms. The proposed method is based on the azotization of the drug compound by sodium nitrite in an acidic medium and then coupling with 2,3dimethyl phenol reagent (DMP) in a basic medium to yield an orange-coloured dye which shows λmax at 402 nm. Different affection of the optimization reaction has been completed, following the classical univariate sequence. The concentration of sulfamethoxazole about (1-15) μg. mL-1 with molar absorptivity of (14943.461) L.mol1 .cm-1 that obeyed Beer’s law. The detection and quantification limits were (0.852, 2.583) μg. mL-1 respectively, while the value of Sandell’s sensitivity (

... Show More
Preview PDF
Publication Date
Sun Jun 07 2015
Journal Name
Baghdad Science Journal
Spectrophotometric Determination of Paracetamol in bulk and Pharmaceutical Preparations
...Show More Authors

A simple, and rapid spectrophotometric method for the estimation of paracetamol has been developed. The methods is based on diazotisation of 2,4-dichloroaniline followed by a coupling reaction with paracetamol in sodium hydroxide medium. All variables affecting the reaction conditions were carefully studied. Beer's law is obeyed in the concentration range of 4-350 ?gml?1 at 490 nm .The method is successfully employed for the determination of paracetamol in pharmaceutical preparations. No interferes observed in the proposed method. Analytical parameters such as accuracy and precision have been established for the method and evaluated statistically to assess the application of the method.

View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Wed Jul 30 2025
Journal Name
Industrial Laboratory. Diagnostics Of Materials
Simultaneous determination of metronidazole and thiamine using UV-spectroscopy
...Show More Authors

The development of analytical techniques is required for the accurate and comprehensive detection and measurement of antibiotic contamination in the environment. Metronidazole is a common antibacterial, antiprotozoal, and antibiotic drug. Thiamine is a vital biological and medicinal ingredient that is involved in the metabolism of proteins, fats, and carbohydrates that produce energy. The study aims to identify the drugs in a mixture without separation to provide more information to confirm if a drug is present in a combination. Metronidazole and thiamine are two examples of pharmaceutical and environmental samples that can be identified using spectrophotometric techniques because of their low cost and simplicity of use. The operati

... Show More
View Publication
Scopus Crossref
Publication Date
Wed Jul 30 2025
Journal Name
Industrial Laboratory. Diagnostics Of Materials
Simultaneous determination of metronidazole and thiamine using UV-spectroscopy
...Show More Authors

The development of analytical techniques is required for the accurate and comprehensive detection and measurement of antibiotic contamination in the environment. Metronidazole is a common antibacterial, antiprotozoal, and antibiotic drug. Thiamine is a vital biological and medicinal ingredient that is involved in the metabolism of proteins, fats, and carbohydrates that produce energy. The study aims to identify the drugs in a mixture without separation to provide more information to confirm if a drug is present in a combination. Metronidazole and thiamine are two examples of pharmaceutical and environmental samples that can be identified using spectrophotometric techniques because of their low cost and simplicity of use. The operati

... Show More
Scopus Crossref
Publication Date
Tue Jan 01 2019
Journal Name
Journal Of Southwest Jiaotong University
Multi -Focus Image Fusion Based on Stationary Wavelet Transform and PCA on YCBCR Color Space
...Show More Authors

The multi-focus image fusion method can fuse more than one focused image to generate a single image with more accurate description. The purpose of image fusion is to generate one image by combining information from many source images of the same scene. In this paper, a multi-focus image fusion method is proposed with a hybrid pixel level obtained in the spatial and transform domains. The proposed method is implemented on multi-focus source images in YCbCr color space. As the first step two-level stationary wavelet transform was applied on the Y channel of two source images. The fused Y channel is implemented by using many fusion rule techniques. The Cb and Cr channels of the source images are fused using principal component analysis (PCA).

... Show More
View Publication Preview PDF
Scopus (1)
Crossref (3)
Scopus Crossref
Publication Date
Mon Feb 01 2021
Journal Name
Iop Conference Series: Materials Science And Engineering
Azo Coupling Reaction for indirect Spectrophotometric Determination of Furosemide using Resorcinol as a Reagent
...Show More Authors
Abstract<p>A simple and accurate method to determinate furosemide (FUR) based on converting the secondary amine to primary amine with acidic hydrolysis then azotization by nitrous acid and coupled with resorcinol as a coupling agent in aqueous medium at pH 13. The optical characteristic like beers law limit found to be (0.25-2.5) μg.ml<sup>−1</sup>, detection and quantification limits (0.0196) (0.0654) μg.ml<sup>−1</sup>respectivly and Sandel sensitivity was 0.006738 μg.cm<sup>−2</sup>. The least-square method was used to evaluate the regression equation and the correlation coefficient. The resulted azo dye has a maximum absorbance at 430 nm with light oran</p> ... Show More
View Publication Preview PDF
Crossref (9)
Crossref
Publication Date
Sat Dec 17 2022
Journal Name
Iraqi Journal Of Laser
PDF Design Optical BPF Using Double Clad Fiber MZI for Free Space Optical Communication: Mohanad G. Khamees , Tahreer S. Mansour*
...Show More Authors

Abstract: A novel design of Mach Zehnder Interferometer (MZI) in terms of using special type of optical fiber that has double clad with graded distribution of the refractive index that can be easily implemented practically was suggested and simulated in this work. The suggested design is compact, rapid, and is simple to be modified and tested. The simulated design contains a MZI of 1546.74 nm of central wavelength that is constructed using special type of double clad optical fiber that has two different numerical apertures. The first aperture will supply single mode propagation via its core, while the second numerical aperture supports a zigzag wave propagation (multimode) in the first clad region. The interferometer’s

... Show More
View Publication Preview PDF
Publication Date
Mon Feb 11 2019
Journal Name
Journal Of Pharmaceutical Sciences And Research
Design of experiments model for optimization of spectrophotometric determination of phenylephrine hydrochloride in pure and pharmaceutical formulations using p-bromanil
...Show More Authors

A simple, fast, inexpensive and sensitive method has been proposed to screen and optimize experimental factors that effecting the determination of phenylephrine hydrochloride (PHE.HCl) in pure and pharmaceutical formulations. The method is based on the development of brown-colored charge transfer (CT) complex with p-Bromanil (p-Br) in an alkaline medium (pH=9) with 1.07 min after heating at 80 °C. ‘Design of Experiments’ (DOE) employing ‘Central Composite Face Centered Design’ (CCF) and ‘Response Surface Methodology’ (RSM) were applied as an improvement to traditional ‘One Variable at Time’ (OVAT) approach to evaluate the effects of variations in selected factors (volume of 5×10-3 M p-Br, heating time, and temperature) on

... Show More
View Publication
Scopus
Publication Date
Mon Jul 01 2013
Journal Name
Iraqi Journal Of Agricultural Sciences مجلة العلوم الزراعية العراقية
EFFECT OF HARROW TYPE AND DRILL SEEDER'S SPEEDS AND DEPTHS ON SOME MACHINERY UNIT TECHNICAL, ECONOMICAL AND ENERGY REQUIREMENT INDICATORS تأثير نوع المنعمة وسٌرع وأعماق البذار في بعض المؤشرات الفنية والأقتصادية ومتطلبات القدرة للوحدة الميكنية
...Show More Authors