Atmospheric transmission is disturbed by scintillation, where scintillation caused more beam divergence. In this work target image spot radius was calculated in presence of atmospheric scintillation. The calculation depend on few relevant equation based on atmospheric parameter (for Middle East), tracking range, expansion ratio of applied beam expander's, receiving unit lens F-number, and the laser wavelength besides photodetector parameter. At maximum target range Rmax =20 km, target image radius is at its maximum Rs=0.4 mm. As the range decreases spot radius decreases too, until the range reaches limit (4 km) at which target image spot radius at its minimum value (0.22 mm). Then as the range decreases, spot radius increases due to geometric optical law. So tracking is possible only in the range from 3 to 11 km, depending on tracking criteria. Target image size minimized to required ratio by using transfocation technique to overcome tracking filler, this technique uses zoom lens.
We find that atmospheric scintillation is affective parameter which reduced the maximum tracking range, and to avoid tracking failure at minimum and maximum range, the transfocation technique is suitable
The research amid to measure the extent of the Suggested procedures of the internal control in accordance with the updated COSO framework in improving the procedures for internal control work in Iraqi oil companies. As the research problem was represented in suggesting procedures for internal control according to the updated COSO framework and finding out the relationship of correlation and influence between the suggested procedures and the internal control procedures that are done in the Iraqi oil companies. The research followed the quantitative approach to handling and analysing data by designing a Questionnaire to represent the research tool for collecting data. The study population was represented in the Iraqi oil companies,
... Show MoreRheumatoid arthritis (RA) is a common inflammatory disease that associated with increased morbidity and mortality due to accelerated atherosclerosis. Rosuvastatin is a unique hydroxy methyl glutaryl Co A (HMGCoA) reductase inhibitor that has anti inflammatory effects.
The aim of this study was to evaluate the effect of rosuvastatin as adjuvant therapy to methotrexate (MTX) on lipid profile and its possible cardioprotective effect in RA patients. A double blinded placebo controlled clinical trial with 8 weeks follow up periods at which 40 patients with active RA using MTX were randomized into 2 groups to receive either rosuvastatin 10mg or placebo as adjuvant therapy to MTX. In addition to twenty healthy subjects as control group.
... Show MoreZinc Oxide thin film of 2 μm thickness has been grown on glass substrate by pulsed laser deposition technique at substrate temperature of 500 oC under the vacuum pressure of 8×10-2 mbar. The optical properties concerning the absorption, and transmission spectra were studied for the prepared thin film. From the transmission spectra, the optical gap and linear refractive index of the ZnO thin film was determined. The structure of the ZnO thin film was tested with X-Ray diffraction and it was formed to be a polycrystalline with many peaks.
This paper reports on the laser emission properties of the BBQ dye in poly (methyl meth-acrylate)(PMMA). This host material combines the advantages of an organic environment for dye with the thermoptical mechanical properties of an organic dye. A BBQ dye solid solution in PMMA polymer. A nitrogen laser in untuned laser cavity has pumped thin films. We developed the concentration and the thickness to get high efficiency. The laser efficiency had been increased from 7% at thickness 1.5 m to 16.5% at thickness 3.5m, and from 1% to 10% when concentration increased from 1x10-5M to 1x10-3 M
A huge potential from researchers was presented for enhancing the nonlinear optical response for materials that interacts by light. In this work, we study the nonlinear optical response for chemically prepared nano- fluid of silver nanoparticles in de-ionized water with TSC (Tri-sodium citrate) protecting agent. By the means of self-defocusing technique and under CW 473 nm blue laser, the reflected diffraction pattern were observed and recorded by CCD camera. The results demonstrate that, the Ag nano-fluid shows a good third order nonlinear response and the magnitude of the nonlinear refractive index was in the order of 10−7 cm2/W. We determine the maximum change of the nonlinear refractive index and the related phase shift for the mat
... Show MoreThis study investigates the surgical and thermal effects on oral soft tissues produced by CO2 laser emitting at 10.6 micrometers with three different fluences 490.79, 1226.99 and 1840.4 J/cm2. These effects are specifically; incision depth, incision width and the tissue damage width and depth. The results showed that increasing the fluence and /or the number of beam passes increase the average depths of ablation. Moreover, increasing the fluence and the number of beam passes increase the adjacent tissue damage in width and depth. Surgeons using CO2 laser should avoid multiple pulses of the laser beam over the same area, to avoid unintentional tissue damage.