An Expression for the transition charge density is investigated
where the deformation in nuclear collective modes is taken into
consideration besides the shell model transition density. The
inelastic longitudinal C2 and C4 form factors are calculated using
this transition charge density for the Ne Mg 20 24 , , Si 28 and S 32
nuclei. In this work, the core polarization transition density is
evaluated by adopting the shape of Tassie model togther with the
derived form of the ground state two-body charge density
distributions (2BCDD's). It is noticed that the core polarization
effects which represent the collective modes are essential in
obtaining a remarkable agreement between the calculated inelastic
longitudinal F(q)'s and those of experimental data
The Development of Semi – Empirical Relationship for the Determination of the Half –Lives of Even – Even Heavy Nuclei that Emit Alpha – Particles
Scattering and Absorption Efficiencies of Si-Ag Coaxial nanowire (NWs) were simulated using Mie-Lorentz scattering approach. The thickness of Ag shell was fixed at around 10 nm with Si core diameter of (10, 20, 30 and 40) nm. Scattering Efficiencies and Absorption Efficiencies of core-shell nanowire as a function of wavelength (300-2000 nm) within various core diameters were calculated. The study shows a remarkable behavior of scattering for un-polarized light in Silicon nanowire (core only) with wavelength of (320- 500nm). In other words, adding Ag shell has decreased the scattering efficiency of core-shell nanowire for all diameters.
Simple and sensitive kinetic methods are developed for the determination of Paracetamol in pure form and in pharmaceutical preparations. The methods are based on direct reaction (oxidative-coupling reaction) of Paracetamol with o-cresol in the presence of sodium periodate in alkaline medium, to form an intense blue-water-soluble dye that is stable at room temperature, and was followed spectrophotometriclly at λmax= 612 nm. The reaction was studied kinetically by Initial rate and fixed time (at 25 minutes) methods, and the optimization of conditions were fixed. The calibration graphs for drug determination were linear in the concentration ranges (1-7 μg.ml-1) for the initial rate and (1-10 μg.ml-1) for the fixed time methods at 25 min.
... Show MoreA new Turbidimetric method characterized by simplicity, accuracy and speed for determination of Hydronium ion by continuous flow injection analysis. The method was based on the formation of complex Zn3[Fe(CN)6] for Zinc(II) that was eluted by Hydronium ion from cation exchanger column with Potassium hexacyanoferrate(III) for the formation of a pale yellow precipitate and this precipitate was determined using homemade Linear Array Ayah-5SX1-T-1D continuous flow injection analyser. The optimum parameters were 2.7 mL.min-1 flow rate using H2O as a carrier stream, 1.7 mL.min-1 reagent stream, 110 L sample volume and open valve for the purge of the sample segment. Data treatment shows that linear range 0.01-0.1 mol.L-1 for each acids (HClO
... Show MoreA new Turbidimetric method characterized by simplicity, accuracy and speed for determination of Hydronium ion by continuous flow injection analysis. The method was based on the formation of complex Zn3[Fe(CN)6] for Zinc(II) that was eluted by Hydronium ion from cation exchanger column with Potassium hexacyanoferrate(III) for the formation of a pale yellow precipitate and this precipitate was determined using homemade Linear Array Ayah-5SX1-T-1D continuous flow injection analyser. The optimum parameters were 2.7 mL.min-1 flow rate using H2O as a carrier stream, 1.7 mL.min-1 reagent stream, 110 L sample volume and open valve for the purge of the sample segment. Data treatment shows that linear range 0.01-0.1 mol.L-1 for each acids (HClO
... Show MoreThe study of Mars's ionosphere was made by investigating the measurements of the electron density (Ne) depending of the variation of the solar activities through different local time, different seasons, and different altitudes. The datasets has been taken from MARSIS on board the Mars Express spacecraft, the investigation for the solar indices and the electron density (Ne) have been made for two period of time depending on the strength of the geomagnetic storms, the first one was taken when the geomagnetic storms was low as in years (1998 & 2005), the data was chosen for three seasons of these years, Winter (December), Summer (June) and Spring (April). The second period was taken for the years (2001 & 2002) when the geomagnetic s
... Show MoreThe study of Mars's ionosphere was made by investigating the measurements of the electron density (Ne) depending of the variation of the solar activities through different local time, different seasons, and different altitudes. The datasets has been taken from MARSIS on board the Mars Express spacecraft, the investigation for the solar indices and the electron density (Ne) have been made for two period of time depending on the strength of the geomagnetic storms, the first one was taken when the geomagnetic storms was low as in years (1998 & 2005), the data was chosen for three seasons of these years, Winter (December), Summer (June) and Spring (April). The second period was taken for the years (2001 & 2002) when the geomagnetic s
... Show MoreThe electric quadrupole moments for some scandium isotopes (41, 43, 44, 45, 46, 47Sc) have been calculated using the shell model in the proton-neutron formalism. Excitations out of major shell model space were taken into account through a microscopic theory which is called core polarization effectives. The set of effective charges adopted in the theoretical calculations emerging about the core polarization effect. NushellX@MSU code was used to calculate one body density matrix (OBDM). The simple harmonic oscillator potential has been used to generate the single particle matrix elements. Our theoretical calculations for the quadrupole moments used the two types of effective interactions to obtain the best interaction compared with the exp
... Show MoreThe present calculation covers the building shield during irradiation process and under water storage of three milion curries Cobalt-60 radiation source the calculation results in design requirement of 8m depth of water in the source stoeage pool