Preferred Language
Articles
/
ijp-794
Two dimensional grating and efficiency enhancement of Si photovoltaic cells by surface texturing using UV femtosecond laser pulses
...Show More Authors

A fast laser texturing technique has been utilized to produce micro/nano surface textures in Silicon by means of UV femtosecond laser. We have prepared good absorber surface for photovoltaic cells. The textured Silicon surface absorbs the incident light greater than the non-textured surface. The results show a photovoltaic current increase about 21.3% for photovoltaic cell with two-dimensional pattern as compared to the same cell without texturing.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Sep 05 2010
Journal Name
Baghdad Science Journal
The effect of solar cells distribution on the Performance of solar panel
...Show More Authors

Three different distribution modules of silicon solar cells in a panel are used in this study . Each module consists of five identical circular silicon solar cells of radius (5cm) and then the total panel areas are identical. The five solar cells are arranged in the panel in different shapes: circular, triangular and rectangular .The efficiency for these three panel distribution are measured indoor and outdoor. The results show that the efficiency is a function of the cells distribution.

View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Thu Jan 01 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of different palatal vault shapes and woven glass fiber reinforcement on dimensional stability of high impact acrylic denture base [part II]
...Show More Authors

Background: Change in palatal vault shape and Reinforcement of high impact acrylic denture base resin may in turn affect the dimensional accuracy of acrylic resin and affecting the fitness of the denture. The aim of study is to evaluate the effect of fiber reinforcement for high-impact acrylic resin denture base with different palatal vault shapes on linear dimensional change and effect of palatal vault shapes on linear dimensional changes of non-reinforced and fiber reinforced high impact denture base acrylic resin Material and method: Three different palatal vault shapes were prepared on standard casts using CNC (computer numerical control) machine. 60 samples of heat polymerized high impact acrylic resin maxillary denture base were fabri

... Show More
View Publication Preview PDF
Publication Date
Thu Jan 01 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of different palatal vault shapes and woven glass fiber reinforcement on dimensional stability of high impact acrylic denture base [Part I]
...Show More Authors

Background: Change in palatal vault shape and Reinforcement of high impact acrylic denture base resin may in turn affect the dimensional accuracy of acrylic resin and affecting the fitness of the denture.This study evaluated tostudy the effect of fiber reinforcement for high-impact acrylic resin denture base with different palatal vault shapes on adaptation or gap space between the denture base and the stone cast and compare with non-fiber reinforcement and effect of palatal vault shapes on adaptation of non-reinforced and fiber reinforced high impact denture base acrylic resin Material and method: Three different palatal vault shapes were prepared on standard casts using CNC (computer numerical control) machine. 60 samples of heat polymeri

... Show More
View Publication Preview PDF
Publication Date
Sat Jun 03 2017
Journal Name
International Journal Of Science And Research
The Sealing Ability of New Bioceramic Material Used to Repair Furcal Perforation Compared with the Traditional Repair Materials: UV Spectrophotometer Analysis
...Show More Authors

Abstract: Iatrogenic furcal root perforations are serious complications during dental treatment. This study was aimed to compare the sealing ability of new bioceramic root repair material TotalFill® with the other perforation repair materials (GIC, MTA and Biodentine) using a dye- extraction method.Materials and Methods: Forty extracted, human mandibular molars with non-fused well developed root were collected. Artificial perforations were made from the external surface of the teeth. Then the teeth were randomly divided into 4 experimental groups (n= 10) according to the type of repair material used in this study; Medifil glass ionomercement, TotalFill® bioceramic root repair material, BiodentineTM and MTA Plus. The specimens were then im

... Show More
Preview PDF
Publication Date
Fri Jan 01 2021
Journal Name
Iraqi Journal Of Agricultural Sciences
Effect of cultural media and nutrient solution on quality and production of cucumber by using hydroponic system.
...Show More Authors

Publication Date
Sun Jun 05 2016
Journal Name
Baghdad Science Journal
Synthesis and Characterization of Multishapes of Fe3O4 Nanoparticle by Solve-Hydrothermal Method Using Microwave Radiation
...Show More Authors

Iron oxide(Fe3O4) nanoparticles of different sizes and shapes were synthesized by solve-hydrothermal reaction assisted by microwave irradiation using ferrous ammonium sulfate as a metal precursor, oleic acid as dispersing agent, ethanol as reducing agent and NaOH as precipitating agent at pH=12. The synthesized Fe3O4 nano particles were characterized by X-ray diffraction (XRD), FTIR and thermal analysis TG-DTG. Sizes and shapes of Fe3O4 nanoparticles were characterized by Scanning Electron Microscopy (SEM), and atomic force microscopy (AFM).

View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Wed Nov 28 2018
Journal Name
International Journal Of Engineering & Technology
Improvement of Gypsum Soil by Using Polyurethane to Reduce Erosion and Solubility of Irrigation Canals
...Show More Authors

The reducing of erosion and the solubility of irrigation canals soils which constructed on gypsum soil is important in civil and water resources engineering. The main problem of gypsum soils is the presence of gypsum which represents one of most complex engineering problems, especially when accompanied by the moving of water which represent dynamic load along the canal. There are several solutions to this problem, in this research “Poly urethane” is used to give the gypsum soil sufficient hardness to reduce the solubility and erosion, after compacting the soil in the canal, percentages of Poly urethane was used to making cover to the soil by mixing percent of soil with Poly urethane, and the ratio was as follows: (5 and 10) % an

... Show More
View Publication
Crossref
Publication Date
Thu Feb 07 2019
Journal Name
Iraqi Journal Of Laser
Investigation of Nonlinear Optical Characteristics of the Multi-Wall Carbon Nanotubes (MWCNT's) Suspensions using Nonlinear Self-Diffraction of a Laser Beam
...Show More Authors

Nonlinear diffraction patterns can be obtained by focusing a laser beam through a thin slice of the material. Here, we investigated experimentally the formation of the far field nonlinear diffraction patterns of cw laser beam at 532 nm passing through a quartz cuvette containing multi-wall carbon nanotubes (MWCNT's) suspended in acetone and in DI water at concentrations of 0.030.wt.%, 0.045 wt.%, 0.060 wt.%, and 0.075 wt.%. Our results show that increasing the concentration of both types of suspensions (MWCNTs in acetone and MWCNTs DI water) led to increase in the number of pattern rings which indicates an increase in their nonlinear refractive indices. Moreover, MWCNTs DI water suspension at a concentration of 0.075 wt. % was more effic

... Show More
View Publication Preview PDF
Publication Date
Sun Mar 04 2012
Journal Name
Baghdad Science Journal
Effect of Temperature on Reliability and Degradation of 0.63?m Laser Diode
...Show More Authors

The reliability of optical sources is strongly dependent on the degradation and device characteristics are critically dependent on temperature. The degradation behaviours and reliability test results for the laser diode device (Sony-DL3148-025) will be presented .These devices are usually highly reliable. The degradation behaviour was exhibited in several aging tests, and device lifetimes were then estimated. The temperature dependence of 0.63?m lasers was studied. An aging test with constant light power operation of 5mW was carried out at 10, 25, 50 and 70°C for 100hours. Lifetimes of the optical sources have greatly improved, and these optical sources can be applied to various types of transmission systems. Within this degradation range,

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sat Oct 27 2018
Journal Name
Surface And Coatings Technology
Effect of surface treatment of zirconia-ceramic dental restorations
...Show More Authors

The zirconia ceramic restoration (ZCR) is used as substitutes for the metal-ceramic restoration. Clinical studies demonstrating of ZCRs showed a high fracture incidence of veneering layer than metal-ceramic restorations. This attributed to the low bond strength of zirconia to veneering ceramic as a result of lacking of glass content in its matrix. Surface treatment was proposed to improve the bonding strength between zirconia and veneering ceramic. Several studies revealed that some treatment such as airborne particle abrasion (APA) is responsible for generating chipping of veneering ceramic. The study aimed to develop a new zirconia coatings to increase bonding strength between zirconia substrate and veneering porcelain. Three groups of 15

... Show More
Preview PDF