Preferred Language
Articles
/
ijp-767
Determination the dispersion parameters and urbach tail of iron chromate doped PMMA films
...Show More Authors

Films of pure Poly (methyl methacrylate) PMMA and Iron chromate doped PMMA have been prepared using casting method. Transmission and absorptance spectra have been recorded in the wavelength range (300-900) nm, in order to calculate, single oscillator energy, dispersion energy proposed by Wemple - DiDomenico model, average oscillator strength, average oscillator wavelength. The refractive index data at infinite wavelength which was found to obey single oscillator model which was found to increase from 2.27-2.56 as the doping percentage increase. The decreasing in the optical energy gap which was found according to Tauc model were (3.74-3.63) eV , is in good agreement with that obtained by wimple-DiDomenico model. The inverse behavior compared with the value of the energy gap were obtained for Urbach energies by increasing from (266-308) meV upon doping

View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
Influence of the annealing time on the structural properties for Flash evaporated InSb films
...Show More Authors

Indium Antimonide (InSb) thin films were grown onto well cleaned glass substrates at substrate temperatures (473 K) by flash evaporation. X-ray diffraction studies confirm the polycrystalline of the films and the films show preferential orientation along the (111) plane .The particle size increases with the increase of annealing time .The transmission spectra of prepared samples were found to be in the range (400-5000 cm-1 ) from FTIR study . This indicates that the crystallinity is improved in the films deposited at higher annealing time.

View Publication Preview PDF
Crossref
Publication Date
Mon Jan 01 2024
Journal Name
International Journal Of Clinical And Diagnostic Pathology
Evaluation of transferrin saturation and serum ferritin in assessing body iron status in patients with end stage renal disease
...Show More Authors

The study aimed to evaluate the benefits of transferrin saturation percentage (TSAT) and serum ferritin in assessing body iron status, which can influence erythropoietin treatment in patients with ESRD. Forty end-stage renal disease patients on regular hemodialysis participated in this study. Clinical data were obtained. Serum iron, total iron binding capacity, transferrin saturation, ferritin, albumin, creatinine, and C-reactive protein were investigated. Thirty healthy people were enrolled as a control group. ESRD patients had a mean age of 45.1±13.9 years, with 60% being males. They exhibited significantly lower hematocrit (25.3±6.5%), and higher platelet (285.7±148.1x10^9/L) and WBC (9.4±3.1x10^9/L) counts compared to healthy contro

... Show More
View Publication
Crossref
Publication Date
Tue Mar 30 2010
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Separation of Bovine Serum Albumin Using Chromatographical Column: Parameters and Simulation
...Show More Authors

A liquid-solid chromatography of Bovine Serum Albumin (BSA) on (diethylaminoethyl-cellulose) DEAE-cellulose adsorbent is worked experimentally, to study the effect of changing the influent concentration of (0.125, 0.25, 0.5, and 1 mg/ml) at constant volumetric flow rate Q=1ml/min. And the effect of changing the volumetric flow rate (1, 3, 5, and 10 ml/min) at constant influent concentration of Co=0.125mg/ml. By using a glass column of (1.5cm) I.D and (50cm) length, packed with adsorbent of DEAE-cellulose of height (7cm). The influent is introduced in to the column using peristaltic pump and the effluent concentration is investigated using UV-spectrophotometer at 30oC and 280nm wavelength. A spread (steeper) break-through curve is gained

... Show More
View Publication Preview PDF
Publication Date
Tue May 01 2012
Journal Name
Iraqi Journal Of Physics
Detection of line shape parameters in normal and abnormal biological tissues
...Show More Authors

Doppler broadening technique is suggested to monitor the development of tumours. It depends on the sensitivity of positronium (Ps) annihilation parameters to the sub- microstructural changes in biological tissues. This technique uses high resolution HpGe detector to measure the lineshape parameters (S and W) in normal mice's mammary tissues and adenocarcinoma mammary tissues as a function of tumour growth. The results demonstrate that the central parameter (S) decreases and the wing parameter (W) increases as the tumour grow. It is found that the S parameter changes considerably with the distribution of voids which are affected by the tumour development. Therefore the present technique can successfully be employed to monitor the developm

... Show More
View Publication Preview PDF
Publication Date
Thu Dec 30 2010
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
DETERMINATION OF THE OPTIMUM OPERATING CONDITIONS IN THE GRANULATION OF GAMMA ALUMINA CATALYST SUPPORT
...Show More Authors

Granulation Technique for Gamma Alumina Catalyst Support was employed in inclined disk granulator (IDG), rotary drum granulator (RD) and extrusion – spheronization equipments .Product with wide size range can be produced with only few parameters like rpm of equipment, ratio of binder and angle of inclination. The investigation was conducted for determination the optimum operating conditions in the three above different granulation equipments.
Results reveal that the optimum operating conditions to get maximum granulation occurred at ( speed: 31rpm , Inclination:420 , binder ratio:225,300% ) for the IDG,( speed: 68rpm , Inclination: 12.50 , binder ratio: 300% ) for the RD and ( speed:1200rpm , time of rotation: 1-2min )for the Caleva

... Show More
View Publication Preview PDF
Publication Date
Thu Dec 04 2014
Journal Name
Engineering And Technology Journal
Optimization of the Time Required for Determination of the Total Dissolved Salts in Soil ‫
...Show More Authors

Publication Date
Mon Jan 06 2020
Journal Name
Plant Archives
ROLE OF ANALYTICAL CHEMISTRY FOR THE DETERMINATION OF ASCORBIC ACID: A REVIEW
...Show More Authors

Vitamins play an important role in the human health, and thus they are the kind of major nutrients in the body. Chemical products perform numerous physiological functions and can jeopardize health jointly in their absence and surplus. Therefore, it is necessary to establish methods for observation vitamin levels in various molds. In this review paper, the most methods of determination used are high performance liquid chromatography (HPLC), spectrophotometric and potentiometric techniques by listed the value of : slope, linear range, correlation coefficient, detection limit, the max of wavelength and PH and compared with these methods.

Publication Date
Mon Mar 08 2021
Journal Name
Baghdad Science Journal
Determination of the neutron refleetion coefficient as a function of reflector material
...Show More Authors

This work presents a simple method for determination of the neutron reflection coefficient (n) as a function of different neutron reflector materials.A laboratory neutron source (Am-Be) with activity of 16 ci is employed with a (BF3) neutron detector. Am-BeThree types of reflector materials are used as samples, the thickness of each sample is (5cm).It is found that( ?7) is: -For polyethlyene = 0.818

View Publication Preview PDF
Publication Date
Fri Dec 01 2017
Journal Name
Journal Of Economics And Administrative Sciences
Comparing the Sequential Nonlinear least squared Method and Sequential robust M method to estimate the parameters of Two Dimensional sinusoidal signal model:
...Show More Authors

Estimation of the unknown parameters in 2-D sinusoidal signal model can be considered as important and difficult problem. Due to the difficulty to find estimate of all the parameters of this type of models at the same time, we propose sequential non-liner least squares method and sequential robust  M method after their development through the use of sequential  approach in the estimate suggested by Prasad et al to estimate unknown frequencies and amplitudes for the 2-D sinusoidal compounds but depending on Downhill Simplex Algorithm in solving non-linear equations for the purpose of obtaining non-linear parameters estimation which represents frequencies and then use of least squares formula to estimate

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Dec 15 2017
Journal Name
Journal Of Baghdad College Of Dentistry
Determination of Implant Primary Stability: A Comparison of the Surgeon’s Tactile Sense and Objective Measurements
...Show More Authors

Background: Evaluation and measurement of primary stability could be achieved by several methods, including the resonance frequency analysis (RFA) and implant insertion torque (IT) values. The need for a sufficient primary stability, guaranteed by an adequate insertion torque and implant stability quotient values, increased its importance mainly in one stage implants or in immediate loading protocols. The aims of this study was to find if there is a correlation between the peak insertion torque (PIT) and ISQ values of implants inserted in the jaws of different bone quality which regarded as two important clinical determinant factors for prediction of implant primary stability, and to evaluate and compare whether an experienced clinician cou

... Show More
View Publication Preview PDF
Crossref