Preferred Language
Articles
/
ijp-739
Double probe for measuring the plasma parameters
...Show More Authors

In this work the diode planer magnetron sputtering device was
designed and fabricated. This device consists of two aluminum discs
(8cm) diameter and (5mm) thick. The distance between the two
electrodes is 2cm, 3cm, 4cm and 5cm.
Design and construction a double probe of tungsten wire with
(0.1mm) diameter and (1.2mm) length has been done to investigate
electron temperature, electron and ion density under different
distances between cathode and anode. The probes were situated in
the center of plasma between anode and cathode.
The results of this work show that, when the distance between
cathode and anode increased, the electron temperature decreased.
Also, the electron density increases with the increasing of the
distance between the two electrodes. The behavior of ion density is
similar to that of electrons but the value is higher

View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon May 08 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Preparing the Thin Films from Laser Dye Dopped with Polymer and Measuring Thickness
...Show More Authors

 Thin films were prepared from melting coumrin C 2 dye in solvent DMF with PMMA with the same  solvent and concentrations(1*10-2    5*10-3, 1*10-3  )M ,Films were either left on Flat surface for24hours or dried in avacuum oven for five hours at a temperature of 80c.The relative intensity of both the absorption and fluorescece spectrum are found to be increased with the increase of thickness of these films and concentration  .Also the thickness of these films was measured by Mickelsons interfearing method.Also quantum efficiency of these films were measured too

View Publication Preview PDF
Publication Date
Sat Dec 01 2018
Journal Name
Journal Of Economics And Administrative Sciences
Measuring The Level of Complexity In The Process University – Case Study At The Southern Technical University.
...Show More Authors

    Complexity is the inherent characteristic of contemporary organizations. It is characterized by the intertwining and expansion of its relations, by the severe disorder and rapid change in its environment, which makes it suffer from a state of uncertainty in determining the direction of its future or the assessment of the rules governing its paths. All organizations tend to evolve with increasing sophistication, And to take measures that contribute to the simplification of the system as it moves towards complexity, allowing the administration to easily control its movement and directions, and the problem of complexity in the university is based on the entanglement and overlap in the goals and processes betwe

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Mar 01 2013
Journal Name
International Journal Of Recent Research And Review
Influence of Discharge Pressure on the Plasma Parameter in a Planar Dc-Sputtering Discharge of Argon
...Show More Authors

Abstract- Plasma parameters in a planar dc-sputtering discharge in argon were measured by cylindrical electrostatic probe (Langmuir probe).Electron density, electron temperature, floating potential, and space potential were monitored as a function of working discharge pressure. Electrostatic probe and supporting circuit were described and used to plot the current – voltage characteristics. Plasma properties were inferred from the current-voltage characteristics of a single probe positioned at the inter-cathode space. Typical values are in the range of (10-16 -10-17) m-3 and (2.93 – 5.3) eV for the electron density and the electron temperature respectively.

Preview PDF
Publication Date
Fri Nov 11 2022
Journal Name
International Journal Of Professional Business Review
Measuring the Level of Performance of Accounting Units and Their Impact on the Control Environment
...Show More Authors

Purpose: The research aims to study the measurement of the performance of accounting units level of the research sample by using the Federal quality Model European (EFQM)   Design/methodology/approach: the (EFQM) which included seven dimensions "Leadership, Strategic Planning, External Focus, Information and Analysis, Faculty / Staff and Workplace Focus, Process Effectiveness & Outcomes and Achievements" And its effect on the Control Environment, which includes three dimensions: "Integrity, management philosophy and commitment to powers" . the sample is supervisory units of colleges affiliated with the University of Baghdad in Iraq, and a sample was chosen that included fifty-one individuals in the accounting departments.

... Show More
View Publication
Scopus (24)
Crossref (4)
Scopus Crossref
Publication Date
Sat Jun 01 2019
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
Measuring the Performance of IT Governance According to COBIT5 Framework by Using the Balanced Scorecard
...Show More Authors

The research aims to clarify the COBIT5 framework for IT governance and to develop of a criterion based on Balanced Scorecard that contributes in measuring the performance of IT governance. To achieve these goals, the researchers adopted the deductive approach in the design of balanced scorecard to measure the IT governance at the Bank of Baghdad that was chosen because it relied heavily on IT.

The research has reached a number of conclusions, the most important of which is that the performance of IT department in the Bank of Baghdad falls within the good level that requires constant monitoring, the most committed items of Balanced Scorecard by the Bank were customer, internal operation, growth and finally the financial item; IT

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Aug 01 2018
Journal Name
Journal Of Economics And Administrative Sciences
Comparing parameters and Reliability of two-parameters exponential
...Show More Authors

One of the most important problems in the statistical inference is estimating parameters and Reliability parameter and also interval estimation , and testing hypothesis . estimating two parameters of exponential distribution and also reliability parameter in a stress-strength model.

This parameter deals with estimating the scale parameter and the Location parameter µ , of two exponential distribution   ,using moments estimator and maximum likelihood estimator , also we estimate the parameter R=pr(x>y), where x,y are two- parameter independent exponential random variables .

Statistical properties of this distribution and its properti

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Aug 05 2022
Journal Name
Spectroscopy Europe
Raman spectroscopy analysis for monitoring of chemical composition of aspirin after exposure to plasma flame
...Show More Authors

A Raman spectroscopy method was optimised to examine the chemical changes of aspirin tablets after interaction with helium temperatures. Several aspirin tablets were exposed to plasma-assisted desorption ionisation flame for different times (10, 30, 50, 60, 180 and 300s) and then analysed by Raman spectroscopy using optimal conditions. The changes in chemistry between exposed and fresh (without exposure to plasma) tablets were compared. The vibrational peaks of the aspirin molecule in the Raman spectrum were identified by checking the peak position. The results showed clear spectra with increases in intensity of vibrational peaks until 30s, whereas no spectra were measured for the exposed tablets to plasma flame after 50s. It can, the

... Show More
Preview PDF
Scopus (10)
Scopus
Publication Date
Fri Jan 10 2025
Journal Name
Chemchemtech
LC-MS/MS METHOD FOR THE DETERMINATION OF IMATINIB MESYLATE IN BLOOD PLASMA SAMPLES AFTER ADSORPTION BY COPPER TANNIC ACID
...Show More Authors

A novel metal-organic framework (MOF) sorbent based on tannic acid/copper (TA/Cu) was synthesized and characterized for the application of the anticancer drug imatinib (IMA) from biological samples. The TA/Cu MOF was prepared via a facile coordination reaction and thoroughly characterized by SEM, XRD, and FTIR techniques. Critical parameters influencing the extraction efficiency of imatinib mesylate (IMAM), including pH, ionic strength, desorption solvent, and adsorption-desorption time were optimized. With acetonitrile as the desorption solvent, the method demonstrated a broad linear range of 0.55-300 μg L-1 under ideal conditions. Limits of detection and quantification were found to be 0.16 μg L-1 and 0.55 μg L-1, respectively.

... Show More
View Publication
Scopus (1)
Scopus Clarivate Crossref
Publication Date
Fri Jan 10 2025
Journal Name
Chemchemtech
LC-MS/MS METHOD FOR THE DETERMINATION OF IMATINIB MESYLATE IN BLOOD PLASMA SAMPLES AFTER ADSORPTION BY COPPER TANNIC ACID
...Show More Authors

A novel metal-organic framework (MOF) sorbent based on tannic acid/copper (TA/Cu) was synthesized and characterized for the application of the anticancer drug imatinib (IMA) from biological samples. The TA/Cu MOF was prepared via a facile coordination reaction and thoroughly characterized by SEM, XRD, and FTIR techniques. Critical parameters influencing the extraction efficiency of imatinib mesylate (IMAM), including pH, ionic strength, desorption solvent, and adsorption-desorption time were optimized. With acetonitrile as the desorption solvent, the method demonstrated a broad linear range of 0.55-300 μg L-1 under ideal conditions. Limits of detection and quantification were found to be 0.16 μg L-1 and 0.55 μg L-1, respectively.

... Show More
View Publication
Scopus (1)
Scopus Clarivate Crossref
Publication Date
Mon Feb 04 2019
Journal Name
Iraqi Journal Of Physics
Diagnostics of low-pressure capacitively coupled RF discharge argon plasma
...Show More Authors

Low-pressure capacitively coupled RF discharge Ar plasma has been studied using Langmuir probe. The electron temperature, electron density and Debay length were calculated under different pressures and electrode gap. In this work the RF Langmuir probe is designed using 4MHz filter as compensation circuit and I-V probe characteristic have been investigated. The pressure varied from 0.07 mbar to 0.1 mbar while electrode gap varied from 2-5 cm. The plasma was generated using power supply at 4MHz frequency with power 300 W. The flowmeter is used to control Argon gas flow in the range of 600 standard cubic centimeters per minute (sccm). The electron temperature drops slowly with pressure and it's gradually decreased when expanding the electro

... Show More
View Publication Preview PDF
Crossref