Radiotherapy is the branch of clinical medicine concerned with the application of ionizing radiation in the treatment of disease. And it is used to killing of cancer cells in a tissue using ionizing radiation while keeping the sparing of healthy cells at acceptable level. X-ray beams are used to deposit absorbed dose at depth within a patient at the site of the tumor. The aim of this work is studying the relationship between the depth dose and the field size in water phantom and homogenous actual planning. In our work, the dose distribution at different depths (zero-18 cm) deep at1cm interval treated with field size (10×10 and 20×20) cm2 were studied.
Results show that high similarity between water phantom and actual planning for this reason water is taken as phantom for Quality Assurance (QA) and calculation the depth dose. When increasing the field size, the percentage of surface dose increases that this could be caused by an increase of the amount of scattering in the larger fields.
Conclusion: There is almost no difference in depth dose between homogenous planning and water phantom.
The aim of study was to explore pharmacist insights toward the impact of prospective implementation of the national health insurance program on patients, providers and Iraqi health system.
This was a qualitative study including semi-structured face-to-face (mostly) interviews with experienced pharmacists. The interview guide included open-ended questions about the impact of the national health insurance program on patients and healthcare providers at three levels: quality of services, costs, and frequency of visits. Potential challenges were also discussed. Interviews were conducted in four provinces from March to May 2022. Thematic analysis was used to analyze the interview findings and generate themes and subthemes.
The
... Show MoreIn this research various of 2,5-disubstituted 1,3,4-oxadiazole (Schiff base, oxo-thiazolidine , and other compounds) were synthesized from 2,5-di(4,4?- amino-1,3,4-oxadiazole ) which use quently synthesized from mixture of 4-amino benzoic acid and hydrazine in the presence of polyphosphorus acid. The synthesized compounds were characterized by using some Spectral data (UV, FT-IR, and 1H-NMR).
The simulation of passively Q-switching is four non – linear first order differential equations. The optimization of passively Q-switching simulation was carried out using the constrained Rosenbrock technique. The maximization option in this technique was utilized to the fourth equation as an objective function; the parameters, γa, γc and β as were dealt with as decision variables. A FORTRAN program was written to determine the optimum values of the decision variables through the simulation of the four coupled equations, for ruby laser Q–switched by Dy +2: CaF2.For different Dy +2:CaF2 molecules number, the values of decision variables was predicted using our written program. The relaxation time of Dy +2: CaF2, used with ruby was
... Show MoreThis article introduces a novel procedure to detect an approximate solution to Fredholm fractional integro-differential equations with linear type (LFFIDE) defined using Caputo fractional derivative. The new procedure approximates the solution using three types of polynomials: Laguerre polynomials, Hermite polynomials, and Legendre polynomials, thereafter transforming the problem into a linear programming problem. The approximate solutions are compared using testing examples to examine the efficiency of the suggested approach. Also, a comparison with the other methods using the same polynomials illustrates The effectiveness and consistency of the proposed technique. Finally, the error analysis of the proposed technique and convergent are di
... Show MoreIn this study, the photodegradation of Congo red dye (CR) in aqueous solution was investigated using Au-Pd/TiO2 as photocatalyst. The concentration of dye, dosage of photocatalyst, amount of H2O2, pH of the medium and temperature were examined to find the optimum values of these parameters. It has been found that 28 ppm was the best dye concentration. The optimum amount of photocatalyst was 0.09 g/75 mL of dye solution when the degradation percent was ~ 96 % after irradiation time of 12 hours, while the best amount of hydrogen peroxide was 7μl/75 mL of dye solution at degradation percent ~97 % after irradiation time of 10 hours, whereas pH 5 was the best value to carry out the reaction at the highest deg
... Show More