Preferred Language
Articles
/
ijp-629
Toxic Gas Response for Nanostructured Cobalt Oxide Thin Films
...Show More Authors

 The gas sensing properties of undoped Co3O4 and doped with Y2O3 nanostructures were investigated. The films were synthesized using the hydrothermal method on a seeded layer. The XRD, SEM analysis and gas sensing properties were investigated for the prepared thin films. XRD analysis showed that all films were polycrystalline, of a cubic structure with crystallite size of (12.6) nm for cobalt oxide and (12.3) nm for the Co3O4:6% Y2O3. The SEM analysis of thin films indicated that all films undoped Co3O4 and doped possessed a nanosphere-like structure.

The sensitivity, response time and recovery time to H2S reducing and NO2 oxidizing gases were tested at different operating temperatures. The resistance changed with exposure to the test gas. The results revealed that the Co3O4:6%Y2O3 possessed the highest sensitivity around 90% (at room temperature) and 62.5% (at 150 oC) when exposed to the reducing gas H2S and oxidizing gas NO2, respectively with 0.8sec for both recovery and response times.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Aug 02 2024
Journal Name
Journal Of Electrochemical Energy Conversion And Storage
Electrochemical Performance of Co1-xMnxFe2O4 Decorated Nanofiber Polyaniline Composites
...Show More Authors

The current work is concerned with preparing cobalt manganese ferrite (Co1-xMnxFe2O4) with different concentrations of cobalt and manganese (x=0.2, 0.4, and 0.6) and decorating it with polyaniline (PAni) for use in supercapacitive applications. The results of the X-ray diffraction (XRD) manifested a broad peak of PAni and a cubic structure of cobalt manganese ferrite having crystal size between 60 nm and 138 nm, which decreases with increasing concentration of Mn. The field emission scanning electron microscopy (FESEM) images evidenced that the PAni has nanofiber (NF) structures, according to the method of preparation, where the hydrothermal method was used. The magnetic properties of the prepared ferrite, as well as the prepared PAni/Co1-x

... Show More
Publication Date
Sun Feb 03 2019
Journal Name
Iraqi Journal Of Physics
Microwave losses of nanostructure Li-Ni ferrites in X-band and Ku-band
...Show More Authors

The molar ratio(x) of Li-Ni ferrites in the formula Li0.5-0.5xNixFe2.5-
0.5xO4 was varied in range 0.1-1.0 by hydrothermal process. The
XRD, SEM, and TEM tests were conducted to examine the samples
crystalline phase and to characterize the particles shapes and sizes.
The high purity spinel structure was obtained at med and high x
values. SEM and TEM images showed the existence of different
ferrite particles shapes like nanospheres and nanorods. The
maximum particle size is around (20nm). These size encourage
occurrence of super paramagnetic state. The reflection loss and
insertion loss as microwave losses of Li-Ni ferrite-epoxy composite
of 1mm thickness and mixing ratio 39.4 wt was investigated. The
mini

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Fri Dec 31 2021
Journal Name
Iraqi Journal Of Laser
The influence of no-core fibre length on the sensitivity Optical fibre Humidity sensor
...Show More Authors

Abstract: Reflection optical fibre Humidity sensor is presented in this work, which is based on no core fibre prepared by splicing a segment of no core fibre (NCF) at different lengths 1-6 cm with fixed diameter 125 µm and a single mode fibre (SMF). The range of humidity inside the chamber is controlled from 30% to 90% RH at temperature ~ 30 °С. The experimental result shows that the resonant wavelength dip shift decreases linearly with an increment of RH% and the sensitivity of the sensor increased linearly with an increasing in the length of NCF. However, a high sensitivity 716.07pm/RH% is obtained at length 5cm with good stability and reputability.  Furthermore, the sensor is shif

... Show More
View Publication Preview PDF
Publication Date
Thu Jan 30 2020
Journal Name
Al-kindy College Medical Journal
Accuracy of Fine Needle Aspiration Biopsy (F.N.A.B) in Diagnosis of Breast Lump
...Show More Authors

Background: Breast cancer is the first one among Iraqi females. Most of them present later for diagnosis. Early detection center in tertiary hospital practice uses FNAB for early diagnosis. Publications on accuracy of this detection are scarce.

Objective:  To test the accuracy of FNAB in breast lump diagnosis.

Methods: Diagnostic test accuracy study, on 204 women with breast lump, attending the oncology department in 2017.

Results: Fine-needle aspiration biopsy diagnosis of histologically malignant cases were, malignant in 89 (87.3%), suspicious of malignancy in 5 (4.9%), and benign in 4 (3.9%). Complete sensitivity was 87.3%, and specificity

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sun Sep 15 2019
Journal Name
Plant Archives
ANTIBACTERIAL ACTIVITY OF CONOCARPUS ERECTUS LEAVES EXTRACTS ON SOME MICROORGANISMS ISOLATED FROM PATIENTS WITH BURN INFECTION
...Show More Authors

Medicinal plants are a source for a wide variety of natural active compounds and are used for the treatment of diseases throughout the world. Conocarpus erectus L. widely planted all over Iraq and has different secondary metabolites, which has been used in treatment of anemia, cancer, fever and diarrhea. The present study aims to estimate the antibacterial activity of Conocarpus erectus leaves extracts on some microorganisms collected from patients with burn infection. The study began with the collection of Conocarpus erectus leaves in June 2018 from the trees in university of Baghdad. Maceration method was used to prepare aqueous extract, while Soxhelt apparatus was used to prepare methanolic extract. The results of phytochemical test show

... Show More
View Publication Preview PDF
Scopus (8)
Scopus
Publication Date
Fri Aug 20 2021
Journal Name
Iraqi Journal Of Laser
The Influence of No-Core Fiber Length on the Sensitivity in Fiber Optic Strain Sensor
...Show More Authors

The influence of sensing element length of no-core fiber strain sensor has been studied and experimentally demonstrated, four different lengths of 125 μm diameter no-core fiber is fused between two standard single-mode fibers and bi-directionally strained, the highest obtained sensitivity was around 16.37 pm με -1 which was exhibited in the shortest no-core fiber segment, to the best of our knowledge this is the first study of the influence of no-core fiber strain sensors length on sensor sensitivity. The proposed sensor can be used in many opto-mechanical applications such as, structural health monitoring, aerospace vehicles and airplane components monitoring.

View Publication Preview PDF
Publication Date
Thu Apr 29 2021
Journal Name
Iraqi Journal Of Science
Capacitance and Resistivity Measurements of Polythiophene /Metallic Nanoparticles-based Humidity Sensors
...Show More Authors

Capacitive–resistive humidity sensors based on polythiophene (P3HT) organic semiconductor as an active material hybrid with three types of metallic nanoparticles (NP) (Ag, Al, and Cu) were synthesized by pulsed laser ablation (PLA). The hybrid P3HT/metallic nanoparticles were deposited on indium-tin-oxide (ITO) substrate at room temperature. The surface morphology of theses samples was studied by using field emission scanning electron micrographs (FE-SEM), which indicated the formation of nanoparticles with grain size of about 50nm. The electrical characteristics of the sensors were examined as a function of the relative humidity levels. The sensors showed an increase in the capacitance with variation in the humidity level.  Whil

... Show More
View Publication Preview PDF
Scopus (9)
Crossref (6)
Scopus Crossref
Publication Date
Wed Oct 11 2023
Journal Name
Journal Of Educational And Psychological Researches
Measuring the Change in the Impact of the Corona Pandemic Factors on Psychological Sensitivity and Covid-19 Phobia in a Sample of University Students
...Show More Authors

The aim of the research is to measure the change in the impact of the factors of the Corona pandemic on psychological sensitivity and COVID-19 phobia in a sample of Bisha University students and to detect the differences in the phobia (phobia) Covid-19 among the sample members in the measurement before the ban and after the ban was opened, in addition to the differences in psychological sensitivity of  The sample has between sizes before and after the spread of the Corona pandemic, as well as the differences in them according to the gender variable (male, female). The researcher relied on the comparative approach. The scale of psychological sensitivity and COVID-19 phobia was applied to a sample of (62) male and female respondents.

... Show More
View Publication Preview PDF
Publication Date
Tue Feb 14 2023
Journal Name
Journal Of Educational And Psychological Researches
Logical Intelligence and its Relationship to the Sensitivity of Sensory Processing of Students in Distinguished Schools
...Show More Authors

Abstract

The research aims to identify the logical intelligence of distinguished students and to identify the extent of the contribution of the fields of logical intelligence to the sensitivity of students' sensory processing in distinguished schools. The research sample consisted of (400) male and female students selected by the stratified random method with the proportional method. The scale that was prepared according to the theoretical framework and the adopted theory was applied after being subject to the psychometric properties of validity and reliability, Logical thinking (observation, interpretation, mathematical and arithmetic operations) contributed to sensory processing. The results showed that disting

... Show More
View Publication Preview PDF
Publication Date
Mon Feb 21 2022
Journal Name
Journal Of Pure And Applied Microbiology
Microbiological Identification of Bacteria with Leukemic Children
...Show More Authors

The most common form of childhood cancer is leukemia, Calculation for more than one third of all childhood cancers among those ages 1 day – 14 years. The diseases of leukemia are worldwide, it occurred in both genders from male and females and in all age. A total of 80 different samples of patient children were collected from the central teaching hospital of pediatric in Baghdad. Obtained during the period from 1st Sept. 2019 till the 31 th of Aug. 2020. Each isolates identification by using Vitek 2. Isolated organism in leukemic children show 18 (22.5 %) gram positive and 62 (77.5 %) gram negative from the total sample 80 (100.0 %). The percent of male is 45 more than female which represents 35 in most age groups between age (1 d

... Show More
View Publication
Scopus Clarivate Crossref