In this study, method for experimentally determining the electron density (ne) and the electron temperature (Te) in the atmospheric Argon plasma jet is used; it is based on optical emission spectroscopy (OES). Boltzmann plot method used to calculate these parameters measured for different values of gas flow rate. The results show that the electron temperature decreasing with the increase of gas flow rate also indicates an increasing in the electron density of plasma jet with increasing of gas flow rate.
Air pollution is one of the complex problems plaguing the environment at the present time
as a result of many liberation of gases, vapors and fumes of fuels and chemicals resulting
from industrial activities . It should be noted that there are some elements of the heavy (Heavy
Metals), including toxic in the air, with different concentrations in the air depending on the
nature of the area, for example be in rural areas is lower than in cities or industrial areas as
measured parts million (ppm ) or parts per billion (ppb). Some of these important elements in
the physiological processes and enzymatic organisms but become toxic and Qatlhand-increase
Tercisahaan the permissible limits Bhave nature ,The air contaminant co
Environmental controls, especially for temperature and humidity, are essential to maintain the safety, purity and effectiveness of drugs. The measurement of humidity can be particularly difficult and important in climatic and thermostatic chambers (warehouses, ovens, cold rooms, fridges, drying rooms, insulated boxes, etc.).
The old method of monitoring and qualification of climatic and thermostatic chambers requires placing a defined number of recorders, then programming and store them. After that, to examine the values recorded to revolve the status of the climatic and thermostatic chambers, if they are compliant or not-complaint at any time, so all that goes to waste time and efficiency of values.
We can do the monitoring and qu
The present study illustrates observations, record accurate description and discussion about the behavior of twelve tested, simply supported, precast, prestressed, segmental, concrete beams with different segment numbers exposed to high fire temperatures of 300°C, 500°C, and 700°C. The test program included thermal tests by using a furnace manufactured for this purpose to expose to high burning temperature (fire flame) nine beams which were loaded with sustaining dead load throughout the burning process. The beams were divided into three groups depending on the precast segments number. All had an identical total length of 3150mm but each had different segment number (9, 7, and 5 segments), in other words, different segment length
... Show MoreAs one type of resistance furnace, the electrical tube furnace (ETF) typically experiences input noise, measurement noise, system uncertainties, unmodeled dynamics and external disturbances, which significantly degrade its temperature control performance. To provide precise, and robust temperature tracking performance for the ETF, a robust composite control (RCC) method is proposed in this paper. The overall RCC method consists of four elements: First, the mathematical model of the ETF system is deduced, then a state feedback control (SFC) is constructed. Third, a novel disturbance observer (DO) is designed to estimate the lumped disturbance with one observer parameter. Moreover, the stability of the closed loop system including controller
... Show MoreThe utilization of recycled brick tile powder as a replacement for conventional filler in the asphalt concrete mix has been studied in this research. This research evaluates the effectiveness of recycled brick tile powder and determines its optimum replacement level. Using recycled brick tile powder is significant from an environmental standpoint as it is a waste product from construction activities. Sixteen asphalt concrete samples were produced, and eight were soaked for a day. Samples contained 5% Bitumen, 2% to 5% brick tile powder, and conventional stone dust filler. The properties of samples were evaluated using the Marshall test. It was observed that the resistance to stiffness and deformation of asphalt concrete
... Show MoreThis paper presents an experimental and theoretical analysis to investigate the two-phase flow boiling heat transfer coefficient and pressure drop of the refrigerant R-134a in the evaporator test section of the refrigeration system under different operating conditions. The test conditions considered are, for heat flux (13.7-36.6) kW/m2, mass flux (52-105) kg/m2.s, vapor quality (0.2-1) and saturation temperature (-15 to -3.7) ˚C. Experiments were carried out using a test rig for a 310W capacity refrigeration system, which is designed and constructed in the current work. Investigating of the experimental results has revealed that, the enhancement in local heat trans
... Show MoreThe aim of this study was to know the inhibition activity of squeezed grape waste extract on Bacillus stearpthermophilus by using three different tempretures degree 40, 60 and 80c, in order to reduce the time exposure of food for preservation. This study include two branchs: First: isolation and identification of Bacillus stearothermophilus from soil, 5 sample were collected from the soil of the college agriculture/Baghdad university. Samples were cultured on nutrient agar, microscopic and culturing tests were conducted and many biochemical tests were done. The isolates were cultivated at 55 c and 65 c for differentiate it from Bacillus coagulans which is can't grow at 65 co. The c
... Show MoreMethotrexate (MTX)is a multiple therapeutic drug, it's used in treatment of ectopic pregnancy, neoplastic disease, autoimmune disorders, and inflammatory conditions. It’s associated with a spectrum of side effect that includes damage to the (liver, kidney, lung and bone marrow). MTX has been associated with fetal malformations in( nervous, skeletal, gastrointestinal, and cardiac) system, and even fetal death. The study was conducted to test the effect of two doses of MTX (5and 10mg/kg) on the development of the mice liver during two gestational age (day11 and day 17) of pregnancy.18 healthy female mice were divided into three groups ,first group (control) was injected with normal saline ,second group injected with 5mg/kg and third grou
... Show MoreTomato (Lycopersicon esculentum Mill) and cucumber (Cucumis sativus L.) seeds were imbided with water at 10°c or 4°c for 4, 8, and 16 hours before planting to study germination rate, mean germination time, and final germination percentage as well as electrolyte leakage from chilled seeds. Seeds imbided more water at 10°c compared to that at 4°c. Coefficient velocity of germination and final percent of germination decreased with the decrease of temperature and increasing time of imbibition. Germination percent under laboratory conditions was higher than that under field conditions. Also, it was found that tomato seeds were more sensitive to chilling imbibition. Electrolyte leakage increased as temperature of imbib
... Show More