In this study, method for experimentally determining the electron density (ne) and the electron temperature (Te) in the atmospheric Argon plasma jet is used; it is based on optical emission spectroscopy (OES). Boltzmann plot method used to calculate these parameters measured for different values of gas flow rate. The results show that the electron temperature decreasing with the increase of gas flow rate also indicates an increasing in the electron density of plasma jet with increasing of gas flow rate.
Statistical studies are reported in this article for an active galactic nuclei sample of different type of active galaxies Seyferts 1, Seyferts 2, and Quasars. These sources have been selected from a Catalogue for bright X-ray galaxies. The name of this index is ROSAT Bright Source Catalogue (RBSC) and the NRAO VLA Sky Survey (NVSS). In this research, multi-wavelength observational bands Radio at 1.4 GHz, Optical at 4400 A0, and X-ray at energy 0.1-2.4 KeV have been adopted in this study. The behavior of flux density ratios has been studied , with respect to the absolute magnitude . Furthermore, the Seyfert1 and Seyfert 2 objects are combined in one group and the QSOs are collectest in another group. Also, it has been fo
... Show MoreStrategies to reduce obesity have become main priority for many health institution and health staff around the world, as the prevalence of obesity has risen and exacerbated in most of the world mainly because of the modern life style which tend to be more sedentary with an increase eating unhealthy fast western food. Many years ago, the lipid-lowering drug simvastatin; and omega-3 were considered as a traditional lipid-lowering drug that have been well-documented to possess anti-inflammatory, cardioprotective and triglyceride-lowering properties; and their co-administration may demonstrate a complementary effect in lowering patients' triglycerides and total cholesterol to treat atherosclero
... Show MoreIn this work, the performance of the receiver in a quantum cryptography system based on BB84 protocol is scaled by calculating the Quantum Bit Error Rate (QBER) of the receiver. To apply this performance test, an optical setup was arranged and a circuit was designed and implemented to calculate the QBER. This electronic circuit is used to calculate the number of counts per second generated by the avalanche photodiodes set in the receiver. The calculated counts per second are used to calculate the QBER for the receiver that gives an indication for the performance of the receiver. Minimum QBER, 6%, was obtained with avalanche photodiode excess voltage equals to 2V and laser diode power of 3.16 nW at avalanche photodiode temperature of -10
... Show MoreFrequent data in weather records is essential for forecasting, numerical model development, and research, but data recording interruptions may occur for various reasons. So, this study aims to find a way to treat these missing data and know their accuracy by comparing them with the original data values. The mean method was used to treat daily and monthly missing temperature data. The results show that treating the monthly temperature data for the stations (Baghdad, Hilla, Basra, Nasiriya, and Samawa) in Iraq for all periods (1980-2020), the percentage for matching between the original and the treating values did not exceed (80%). So, the period was divided into four periods. It was noted that most of the congruence values increased, re
... Show MoreIn this work, the calculation of matter density distributions, elastic charge form factors and size radii for halo 11Be, 19C and 11Li nuclei are calculated. Each nuclide under study are divided into two parts; one for core part and the second for halo part. The core part are studied using harmonic-oscillator radial wave functions, while the halo part are studied using the radial wave functions of Woods-Saxon potential. A very good agreement are obtained with experimental data for matter density distributions and available size radii. Besides, the quadrupole moment for 11Li are generated.
The dose rate for bremsstrahlung radiation from beta particles with energy (1.710) MeV and (2.28) MeV which comes from (32P and 90Y) beta source respectively have been calculated through six materials (polyethylene, wood, aluminum, iron, tungsten and lead) for first shielding material with thickness (x=1) mm which are putting between beta sources and second shield (polyethylene, aluminum and lead) with thickness (1, 2 &4) mm have been calculated. The distance between beta source and second shield is constant (D=1) cm. This dose rate was found by program called Rad Pro Calculator (version 3.26). The results of dose rate of beta particles were plotted as a function to the atomic number (Z) for first shield materials for each
... Show MorePurpose: the purpose of study is estimate the Risk premium, Interest rate, Inflation and FDI in the through of Coronavirus in the MENA countries. Theoretical framework: The theoretical framework included the study of the main variables, which are risk premium, interest rate, inflation, and foreign direct investment during the Corona virus pandemic. Design/methodology/approach: Concentrating on “COVID-19”, as an effective factor on the Foreign direct investment (FDI), I employ data of “MENA (Middle East and Northern Africa)” countries from 2000 to 2021 to investigate the impact of COVID-19, financial and macroeconomic indicators on FDI relying on the analytic research approach of Static panel data regression, includ
... Show MoreThe dose rate for bremsstrahlung radiation from beta particles with energy (1.710) MeV and (2.28) MeV which comes from (32P and 90Y) beta source respectively have been calculated through six materials (polyethylene, wood, aluminum, iron, tungsten and lead) for first shielding material with thickness (x=1) mm which are putting between beta sources and second shield (polyethylene, aluminum and lead) with thickness (1, 2 &4) mm have been calculated. The distance between beta source and second shield is constant (D=1) cm. This dose rate was found by program called Rad Pro Calculator (version 3.26). The results of dose rate of beta particles were plotted as a function to the atomic number (Z) for first shield materials for each
... Show MoreThis study investigates the changes occurring in the province of Basra using geospatial methods and analyzes the variations in land surface temperature among the various types of land cover. For the months of July and December in the years 2013 and 2021, Landsat images were used in Landsat 8 OLI/TIRS, and satellite images were processed using ArcGIS 10.8 software. The study's categories for land use and land cover were generated through the application of supervised classification techniques, and the land surface temperature was calculated using data from a satellite sensor's brightness temperature. According to the study's findings, there has been an increase in urban areas (including barren land). From 2013 to 2021, a greater correlati
... Show MoreThe partial level density PLD of pre-equilibrium reactions that are described by Ericson’s formula has been studied using different formulae of single particle level density . The parameter was used from the equidistant spacing model (ESM) model and the non- equidistant spacing model (non-ESM) and another formula of are derived from the relation between and level density parameter . The formulae used to derive are the Roher formula, Egidy formula, Yukawa formula, and Thomas –Fermi formula. The partial level density results that depend on from the Thomas-Fermi formula show a good agreement with the experimental data.