In this manuscript has investigated the synthesis of plasma-polymerized pyrrole (C4H5N) nano-particles prepared by the proposed atmospheric pressure nonequilibrium plasma jet through the parametric studies, particularly gas flow rate (0.5, 1 and 1.5 L/min). The plasma jet which used operates with alternating voltage 7.5kv and frequency 28kHz. The plasma-flow characteristics were investigated based on optical emission spectroscopy (OES). UV-Vis spectroscopy was used to characterize the oxidization state for polypyrrole. The major absorption appears around 464.1, 449.7 and 435.3 nm at the three flow rate of argon gas. The chemical composition and structural properties of the contained samples which synthesized at 0.5 L/min as a argon flow rate were analyzed by scanning electron microscopy (SEM), Fourier transformation infrared spectroscopy (FTIR), Raman spectroscopy and X-ray diffraction (XRD). SEM point to a uniform distribution of polypyrrole (PPY) nanoparticles matrix. XRD technique showed a semicrystalline pattern for PPY)thin film. It is expected, that the high-quality plasma polymer grown by atmospheric pressure plasma jet method contributes to serving as conducting materials.
Background: Polymer surfaces usually present problems in bonding and finishing due to their low hydrophilicity. The aim of this study is to investigate the effect of plasma treatment with the use of two types of gases (oxygen and argon) on surface roughness, and chemical surface properties of acrylic resin denture base polymer material. Materials and Methods: Three heat cured acrylic resin specimens of (2*8*30 mm) dimensions were prepared for each test carried out in this study. Two tests were conducted, surface roughness test and chemical surface analysis test. Results: Application of plasma treatment increased surface roughness for both oxygen and argon plasma treated acrylic resin specimen groups compared with control untreated group,
... Show More(2000) Summary:
(2001) Background: infertility is defined as the inability of a couple to conceive after one year of a regular unprotected intercourse with the same partner. Many factors seem to play a role in male infertility.
(2002) Aim: to evaluate the role of some seminal plasma biochemical components in male infertility.
(2003) Methods: seminal plasma of 100 infertile men & 25 fertile men were chosen as a subject of this study.
(2004) Different biochemical parameters that are related to oxidative stress were measured. These included Glutathione Peroxidase (GSHPX),superoxide dismutase (SOD),cerulopasmin (CP) scavenging activity, albumin & total sulfhydral (T-SH) & its individual parts (protein & non protei
In this research, the electrical characteristics of glow discharge plasma were studied. Glow discharge plasma generated in a home-made DC magnetron sputtering system, and a DC-power supply of high voltage as input to the discharge electrodes were both utilized. The distance between two electrodes is 4cm. The gas used to produce plasma is argon gas which flows inside the chamber at a rate of 40 sccm. The influence of work function for different target materials (gold, copper, and silver), - 5cm in diameter and around 1mm thickness - different working pressures, and different applied voltages on electrical characteristics (discharge current, discharge potential, and Paschen’s curve) were studied. The results showed that the discharge cur
... Show MoreBackground: Polymethyl methacrylate (PMMA) is the most commonly used material in denture fabrication. The material is far from ideal in fulfilling the mechanical requirements, like low impact and transverse strength, poor thermal conductivity. The purpose of this study was to evaluate the effect of addition a composite of surface treated Nano Aluminum oxide (Al2O3) filler and plasma treated polypropylene fiber (PP) on some properties of denture base material. Materials and methods: One hundred fifty prepared specimens were divided into 5 groups according to the tests, each group consisted of 30 specimens and these were subdivided into 3 groups (unreinforced heat cured acrylic resin as control group),reinforced acrylic resin with( 0.5%wt Nan
... Show MoreAn Investigation of estimated Mechanical Properties of AL-Alloys 2024-T3, which is the most commonly used in industrial applications, been established experimentally. A new novel Plasma Peening techniques had applied for the whole surfaces of the material by CNC-Plasma machine for 48 specimen, and then a new investigation were toke over to figure the amount of change in mechanical properties and estimated fatigue life. It found that improvement was showing a nonlinear behavior according to peening duration time, speed, peening distance, peening number, and amount of effected power on the depth of the material thickness. The major improvement was at medium speed long duration time normal peening distance. Which shows up t
... Show MoreBackground: Tonsillectomy is one of the most common surgical operations in otolaryngology, post-tonsillectomy hemorrhage is a dangerous complication. Several methods have been used to decrease the rate of post-tonsillectomy hemorrhage, one of these methods, a relatively recent method, is local application of platelet-rich plasma (PRP) to the tonsillar beds.
Objectives: To evaluate the role of local application of autologous PRP to the tonsillar beds, at the time of tonsillectomy, in post-tonsillectomy hemorrhage.
Patients and methods: A prospective comparative study enrolled 64 patients with ages ranging from 6 to 10 years who underwent tonsillectomy with or without adenoid
... Show MoreIn this work, radius of shock wave of plasma plume (R) and speed of plasma (U) have been calculated theoretically using Matlab program.
Background: Obesity is a medical condition in which excess body fat has accumulated to the extent that it has an adverse effect on health. . It measured by BMI (body mass index), obesity is considered when the BMI is ≥ 30 kg/m2. It increases the risk of coronary heart disease, Diabetes Mellitus and Cancer. Chronic inflammation and impaired fibrinolysis in obesity may induce thrombosis.
Aim of study: assess the effect of BMI (body mass index) on plasma level of Factor V and fibrinogen in obese and normal weight subjects.
Methods: This study was started on December 2015 and completed on June 2016, and included 51 obese attended alyarmouk Teaching Hospital. As well 2
... Show MoreBacillus subtilis, an isolate of bacillus genus, was obtained from the laboratories of Ministry of Science and Technology. The best efficient Bacillus subtilis isolate in cellulose and semi-cellulose hydrolysis was treated with Dielectric-barrier Discharge (DBD). Atmospheric cold plasma technique (non-thermal) was used by exposing them at different times (2, 3, 4 and 5 mins) separately as a first stage, and then 60 seconds after any treatment separately as a second stage. After 48 hours, the difference between the plasma source and the sample was fixed at 0.5 cm. The results showed a variation in the growth of the isolate according to the exposure time by the appearance of culture turbidity and the estimation o
... Show More