In the present study the radon concentration was measured in indoor places by the RAD7 (radon detector) was in some locations at Al-Tuwaitha nuclear site and some surrounding areas for the duration from 13/10/2016 to 2/1/2017 and the measurement of the indoor radon concentration ranged from (4.96±4.4 to 102±25) Bq/m3. The high value of radon has been found at decommissioning directorate /emergency room, which is lower than the action value recommended by the Environmental Protection Agency (EPA) which is (148 Bq/m3) while the lowest value has been founded in central laboratories directorate \ models room. These values were used to calculate the annual effective dose and the health risks for cells bronchial which caused by the inhalation of radon. The values of the annual effective doses were calculated and ranged from (0.1249 to 2.5704) mSv/y these results are lower than the value of (10 mSv/y) recommended by the International Commission Radiological on Protection (ICRP). The results from this study shows that the region has background radioactivity levels within the natural limits.
At the last two decades , The environment has witnessed tremendous changes in many fields with the huge competition , various technological development and customer satisfaction , that are reflected in economic units a doption for lean production system.
Lean accounting that has appeared as a response for change occurred of economic units adoption for changes occurred of economic units adoption for lean production instead of wide production system , has devised new performance measures suitable for economic units adoption for lean ideas: and helping in providing suitable information about evaluating economic unit performance , these measures are divided into three levels , cell level,value flow level , a
... Show MoreIn this research, radon concentrations in some types of healthy drinking water samples available in Iraq's market were measured using a technique called Durridge RAD-7-H2O with closed loop. Then the rate of annual effective dose in human taken this water is determined.
It was found that, radon concentrations in studied samples ranged between 1.2 Bq.m-3 to 142 Bq.m-3. The results of the radon concentrations and the rate of annual effective dose for drinking water samples were significantly lower than the USEPA and WHO recommended limits that equal 500 Bq/m3 and 1 mSv/y resp
... Show MoreVitrifications process one of the important methods to immobilize nuclear waste. In this research nuclear waste (Strontium Oxides) with molecular weight (5%) was immobilized by vitrification methods in two types of borosilicate glass (c-type) which are glass and glass-ceramics. To investigate the physical, chemical and mechanical properties of glass and glass-ceramic after immobilize nuclear waste these samples irradiated by gamma ray radiation. Co-60 was used as gamma a irradiation with dose rate 0.38 kGy/hr for different period of time. It’s found that gamma radiation affected the glass and glass-ceramic properties. From phase analysis by the x-ray diffraction for glass-ceramic samples proved that at doses 343kGy change the cry
... Show MoreIn the present research we the study the deposition of radioactive elements naturally and particularly radioactive radon gas in parts of the body of organisms which are of direct relevance to human life in the city of Baghdad as the samples which were collected from the bones and skin of some kinds of birds and chicken based on the principle that radioactive elements are concentrated always on the bones. We use of this as the exercise detector impact nuclear (CR-39), using the technology Cylindrical diffusion , the results indicated that the largest concentration of radon found in the bone bird Seagull tapered as it was (625 ± 37) Bq.cm-3, and less concentration of radon gas in the chicken bones of Al-kafeel as it was (105 ± 10) Bq.c
... Show MoreIn the present study twenty samples of human urine were taken
from healthy male and female with different of: ages, occupation and
place of residence. These samples were collected from the hospital to
measure the concentration of radon gas in human urine by using one
of solid state nuclear track detectors LR-115.
The results obtained of the concentrations of radon in healthy human
urine are varying from 2.12×10-3 Bq.l-1 to 4.42×10-3 Bq.l-1 and
these values are less than the allowed limits 12.3×10-3 Bq.l-1.