The Enhanced Thematic Mapper Plus (ETM+) that loaded onboard the Landsat-7 satellite was launched on 15 April 1999. After 4 years, the image collected by this sensor was greatly impacted by the failure of the system’s Scan Line Corrector (SLC), a radiometry error.The median filter is one of the basic building blocks in many image processing situations. Digital images are often distorted by impulse noise due to errors generated by the noise sensor, errors that occur during the conversion of signals from analog-to-digital, as well as errors generated in communication channels. This error inevitably leads to a change in the intensity of some pixels, while some pixels remain unchanged. To remove impulse noise and improve the quality of the image we are working on. In this paper, the Landsat -7 data was corrected from line droop out radiometric errors using the median filter method. we studied the median filter and offer a method based on an improved median filtering algorithm, [2]. We apply the median filter (3 x 3) to correct the image taken by of Landsat 7 and correct it, and we will restore the damaged pixels using the Erdas imagine program.
The aim of the study was to evaluate the efficacy of diode laser (λ=940 nm) in the management of gingival hyperpigmentation compared to the conventional bur method. Materials and methods: Eighteen patients with gingival hyperpigmentation were selected for the study with an age between 12-37 years old. The site of treatment was the upper gingiva using diode laser for the right half and the conventional method for the left half. All patients were re-evaluated after the following intervals: 3 days, 7 days, 1 month and 6 months post-operation. Pain and functions were re-evaluated in each visit for a period of 1 day, 3 days and 1 week post-operation. Laser parameters included 1.5 W in continuous mode with an initiated tip (400 μm) placed in
... Show MoreAS Muhsen, International Journal of Psychosocial Rehabilitation (1475-7192), 2020 - Cited by 1
In this article, a numerical study of compressible and weak compressible Newtonian flows is achieved for a time marching, Galerkin algorithm. A comparison between two numerical techniques for such flows, namely the artificial compressibility method (AC–method) and the fully artificial compressibility method (FAC–method) is performed. In the first artificial compressibility parameter ( is added to the continuity equation, while this parameter is added to both continuity and momentum equations in the second technique. This strategy is implemented to treat the governing equations of Newtonian flow in cylindrical coordinates (axisymmetric). Particularly, this study concerns with the effect of the artificial compressibility p
... Show MoreIn this research, the Williamson-Hall method and of size-strain plot method was employed to analyze X- ray lines for evaluating the crystallite size and lattice strain and of cadmium oxide nanoparticles. the crystallite size value is (15.2 nm) and (93.1 nm) and lattice strain (4.2 x10−4 ) and (21x10−4) respectively. Also, other methods have been employed to evaluate the crystallite size. The current methods are (Sherrer and modified Sherrer methods ) and their results are (14.8 nm) and (13.9nm) respectively. Each method of analysis has a different result because the alteration in the crystallite size and lattice strain calculated according to the Williamson-Hall and size-strain plot methods shows that the non-uniform strain in nan
... Show MoreThe research's aim is to place two teaching methods ( total and analytical method) and to know which one of them is better than the other in teaching the counter-attack with Epee. The researchers have used the experimental method for being considered suitable to solve the problem of the research. The sample of the research includes third –stage female students of college of physical education and sport sciences / Baghdad University in the subject of fencing, their number amounted 60 female students. It has been used SPSS for processing the results. They have concluded that the two groups of the research and the two methods (( total and analytical) have learnt the counter- attack of the two over mentioned groups. they have recommended to c
... Show MoreA new, simple, sensitive and fast developed method was used for the determination of methyldopa in pure and pharmaceutical formulations by using continuous flow injection analysis. This method is based on formation a burgundy color complex between methyldopa andammonium ceric (IV) nitrate in aqueous medium using long distance chasing photometer NAG-ADF-300-2. The linear range for calibration graph was 0.05-8.3 mmol/L for cell A and 0.1-8.5 mmol/L for cell B, and LOD 952.8000 ng /200 µL for cell A and 3.3348 µg /200 µL for cell B respectively with correlation coefficient (r) 0.9994 for cell A and 0.9991 for cell B, RSD % was lower than 1 % for n=8. The results were compared with classical method UV-Spectrophotometric at λ max=280 n
... Show MoreThe fluorescence emission of Rhodamine 6G (R6G) and Acriflavine dyes in PMMA polymer have been studied by changing the irradiation and exposure time of laser light to know the effect of this parameter. It was found that the fluorescence intensity decreases in the polymer samples doped dyes as the exposure time increases and then reaches stabilization at long times, this behavior called photobleaching, which have been shown in liquid phase less than solid phase. Using 2nd harmonic with wavelength 530 nm laser, the photobleaching effect in the two dye-doped polymers different solvent but same was studied. It was observed that photobleaching of by different solution and by using dip spin coating the photobleaching seem in liquid phase more
... Show MoreImages are usually corrupted by type of noise called "mixed noise ", traditional
methods do not give good results with the mixed noise (impulse with Gaussian
noise) .In this paper a Simple Cascade Method (SCM) will be applied for mixed
noise removal (Gaussian plus impulse noise) and compare it's performance with
results that acquired when using the alpha trimmed mean filter and wavelet in
separately. The performances are evaluated in terms of Mean Squane Error (MSE)
and Peak Signal to Noise Ratio (PSNR).