Polymer electrolytes systems compose of (PEO+KI+I2) and (PEO+RbI+I2) with different concentration, and a fixed amount of ethylene carbonate (EC) and propylene carbonate (PC) over temperatures range 293-343 K prepared by solution cast method. The conductivity and dielectric constant of the gel electrolytes were studied. The conductivity of the electrolytes Ss & Hs increases steadily with increased concentration of salt KI and RbI. The higher value of conductivity of (4.7 10-3 @ RT S.cm-1) for S5 electrolyte which contains (KI 50%). Whereas the maximum amount of conductivity of (5.4 10³ @RT S.cm⁻ˡ) for H5 electrolyte which contains (RbI 50%) the ionic conductivity depends on the ionic radii of the migrating species (cation K⁺, Rb⁺) effect on it. As the temperature increase, the number of free ions also increases, thus increases the diffusion of ions through their free volume of the polymer. The dielectric constant decrease at higher frequencies due to the inability of dipoles to align quickly with the change of applied field. The dielectric constant proportional positively with variation temperature causes an increase in the dielectric constant. The higher the value of (εr), the better is the electrical conductivity.
Water absorbent polymers (WAP) are new component in producing building materials. They provide internal curing which reduces autogenous cracking, eliminates autogenous shrinkage, mortar strength increased, enhance early age strength to withstand strain, improve the durability, introduce higher early age compressive strength, have higher performance and reduce the effect of insufficient external curing. This research used different percent of polymer balls to choose the percent that provides good development in compressive strength with time for both water and air curing. The water absorption polymer balls in this research have the ability to absorb water and after usage in concrete they spill out the water (internal curing) and shri
... Show MoreAluminum oxide (ALO) was grafted by acrylic acid monomer (AlO-AM) and then, it was polymerized to produce alumina grafted poly(acrylic acid) (AlO-AP). The prepared AlO-AM and AlO-AP were characterized by Fourier-transform infrared, differential scanning calorimetry , thermogravemetric analyzer and particle size distribution. Adsorption equilibrium isotherms, adsorption kinetics and thermodynamic studies of the batch adsorption process were used to examine the fundamental adsorption properties of phenol (P) and p-chlorophenol (PCP). The experimental equilibrium adsorption data were analyzed by three widely used two-parameters Langmuir, Freundlich and DubininRadushkevich isotherms. The maximum P and PCP adsorption capacities based on t
... Show MorePolyacetal was synthesized from the reaction of PVA with para-methyoxy benzaldehyde. Polymer metal complexwas prepared by reaction with Cu, polymer blend with Chitosan was prepared through the technique of solution casting method.All prepared compounds have been characterized through FT-IR, DSC, SEM as well as the Biological activity. The FT-IR results indicated the formation of polyacetal. The DSC results indicated the thermal stability regarding prepared polymer, polymermetal complex and Chitosan polymer blends. Antibacterial potential related to synthesized polyacetal, its metal complex andChitosan blend against four types of bacteria namely, Staphylococcus aureas, Psedomonas aeruginosa, Bacillus subtilis, Escherichia coli was examined a
... Show MoreThe effects of incorporating lithium carbonate (Li2CO3) into a polyvinyl alcohol/polyvinyl pyrrolidone/polyethylene glycol (PVA/PVP/PEG) blend polymer electrolyte were investigated. Electrolytes were prepared via solution casting method, with Li2CO3 added at 10, 20, and 30 wt.% to the PVA/PVP/PEG blend (50/30/20 ratio). Fourier transform infrared spectroscopy analysis revealed interactions between the added salt and the polymer blend. The addition of both PEG and Li2CO3 resulted in increased ionic conductivity, reaching a maximum of 4.51 x 10- 5 S/cm at 30 degrees C with 20 wt.% Li2CO3. Ionic conductivity also exhibited a positive temperature dependence. Optical analysis showed a decrease in the optical energy gap with the addition of PEG a
... Show MoreAbstract : A research was conducted to study the process parameters affecting hexavalent chromium Cr (VI) (carcinogenic compound) the removal percentage from the electrical industries company waste water that contain 88 mg/l of Cr (VI) concentration by adsorption onto tea wastes. Synthetic water with 88 mg/l Cr (VI) concentration was used. Several operation parameters affecting Cr (VI) removal efficiency were investigated, such as pH, initial Cr (VI) concentration, stirring time and tea wastes dose. The experimental results reveal that maximum Cr (VI) removal reached up to 94.26% at pH of 2, stirring time of 180 minute, tea wastes do
... Show MoreBoth type 1 diabetes and type 2 diabetes have a genetic component, with over 60 chromosomal regions related to type 1 diabetes and over 200 connected with type 2 diabetes at significant genome-wide levels. Numerous single nucleotide polymorphisms in the RETN gene and genetic variables can account for up to 70% of the variations in circulating resistin levels. The RETN polymorphism has been linked in numerous studies to obesity, insulin sensitivity, type 2 diabetes, and cerebrovascular illness. Our objective is to compare this RETN gene 3ʹ-untranslated region polymorphism in type 1 diabetes and type 2 diabetes Iraqi patients. We choose 51 type 1 diabetes and 52 type 2 diabetes patients against 50 healthy subjects (control group) to investig
... Show MoreType 2 daibetes mellitus (T2DM) is a global concern boosted by both population growth and ageing, the majority of affected people are aged between (40- 59 year). The objective of this research was to estimate the impact of age and gender on glycaemic control parameters: Fasting blood glucose (FBC), glycated hemoglobin (HbA1C), insulin, insulin resistance (IR) and insulin sensitivity (IS), renal function parameters: urea, creatinine and oxidative stress parameters: total antioxidant capacity (TAC) and reactive oxygen species (ROS). Eighty-one random samples of T2DM patients (35 men and 46 women) were included in this study, their average age was 52.75±9.63 year. Current study found that FBG, HbA1C and IR were highly significant (P<0.01) inc
... Show MoreThis research is concerned to investigate the behavior of reinforced concrete (RC) deep beams strengthened with carbon fiber reinforced polymer (CFRP) strips. The experimental part of this research is carried out by testing seven RC deep beams having the same dimensions and steel reinforcement which have been divided into two groups according to the strengthening schemes. Group one was consisted of three deep beams strengthened with vertical U-wrapped CFRP strips. While, Group two was consisted of three deep beams strengthened with inclined CFRP strips oriented by 45o with the longitudinal axis of the beam. The remaining beam is kept unstrengthening as a reference beam. For each group, the variable considered
... Show More