Preferred Language
Articles
/
ijp-417
Quality assurance of the linear accelerator device using Star Track and Perspex
...Show More Authors

In this study, the quality assurance of the linear accelerator available at the Baghdad Center for Radiation Therapy and Nuclear Medicine was verified using Star Track and Perspex. The study was established from August to December 2018. This study showed that there was an acceptable variation in the dose output of the linear accelerator. This variation was ±2% and it was within the permissible range according to the recommendations of the manufacturer of the accelerator (Elkta).

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Feb 03 2019
Journal Name
Iraqi Journal Of Physics
Specific activities and radiation hazard parameters calculations of natural radionuclides in AL-Mustansiriyah university soils using NaI(Tl) detector
...Show More Authors

The specific activities of the natural radionuclides U-238 and Th-
232 and K-40 in 14 soil samples collected from different sites from
AL-Mustansiriyah university at two depths (topsoil "surface" and
20cm depth) were be investigated using gamma ray spectrometer
3"x3" NaI(Tl) scintillation detector.
The analysis of the energy spectra of the soil samples show that
these samples have specific activities ranging with (16.08-51.11)
Bq/kg for U-238, (14.79-52.29) Bq/kg for Th-232 and (191.08-
377.64) Bq/kg for K-40, with an average values of 29.37, 34.14 and
289.62 Bq/kg for U-238, Th-232, k-40 respectively. The radiation
hazard parameters of the natural radionuclides; radium equivalent
activity (Raeq), gamma a

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Oct 01 2023
Journal Name
Applied Sciences
Multiobjective Optimization of Stereolithography for Dental Bridge Based on a Simple Shape Model Using Taguchi and Response Surface Methods
...Show More Authors

Stereolithography (SLA) has become an essential photocuring 3D printing process for producing parts of complex shapes from photosensitive resin exposed to UV light. The selection of the best printing parameters for good accuracy and surface quality can be further complicated by the geometric complexity of the models. This work introduces multiobjective optimization of SLA printing of 3D dental bridges based on simple CAD objects. The effect of the best combination of a low-cost resin 3D printer’s machine parameter settings, namely normal exposure time, bottom exposure time and bottom layers for less dimensional deviation and surface roughness, was studied. A multiobjective optimization method was utilized, combining the Taguchi me

... Show More
View Publication
Scopus (4)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Sun Mar 01 2020
Journal Name
Iop Conference Series: Materials Science And Engineering
Using Remote Sensing and GIS in Measuring Vegetation Cover Change from Satellite Imagery in Mosul City, North of Iraq
...Show More Authors
Abstract<p>The aim of the study is the assessment of changes in the land cover within Mosul City in the north of Iraq using Geographic Information Systems (GIS) and remote sensing techniques during the period (2014-2018). Satellite images of the Landsat 8 on this period have been selected to classify images in order to measure normalized difference vegetation index (NDVI) to assess land cover changes within Mosul City. The results indicated that the vegetative distribution ratio in 2014 is 4.98% of the total area under study, decreased to 4.77% in 2015 and then decreased to 4.54 <italic>%</italic> in 2016, after then decreased to 3,59% in 2017,then increased to 4.39% in 2018. Land cove</p> ... Show More
View Publication
Scopus (17)
Crossref (10)
Scopus Crossref
Publication Date
Wed Jul 30 2025
Journal Name
Journal Of Baghdad College Of Dentistry
The influence of cavity design for cusp coverage on fracture strength of weakened maxillary first premolars using two esthetic restorative systems (CAD/CAM hybrid ceramic and nanohybrid composite) (An in vitro study)
...Show More Authors

Background: Maxillary first premolar with wide MOD cavity more susceptible to fracture. The aim of this study was to assess the influence of cavity design for cusp coverage on the fracture resistance of weakened maxillary first premolar restored with CAD/CAM hybrid ceramic versus nanohybide composite. Materials and Methods: Fifty six intact maxillary first premolars of approximately comparable sizes were divided into seven groups eight for each: Group A: Intact teeth (control group); Group B: teeth prepared for MOD inlay; Group C: teeth prepared for MOD onlay covering the lingual cusp; Group D: teeth prepared for MOD covering buccal and lingual cusps ,the previous three groups indirectly restored with nanohybrid composite (3M ESPE Z 250 X

... Show More
View Publication Preview PDF
Publication Date
Thu Oct 10 2019
Journal Name
Journal Of The College Of Education For Women
Constitutional Review of 1992 and 1996 and the role of the Party of Progress and Socialism
...Show More Authors

Constitutional Review of 1992 and 1996 and the role of the Party of Progress and Socialism

View Publication Preview PDF
Publication Date
Tue Dec 01 2009
Journal Name
Journal Of Economics And Administrative Sciences
Evaluation of the efficiency and effectiveness of the accounting system of the Department of Missions and Cultural Relations (*) at the Office of the Ministry of Higher Education and Scientific Research
...Show More Authors

The evaluation and efficiency and effectiveness of account system for the department of delegation and cultural Relationships in the center of ministry of higher Education and Scientific research Considered as a very important and active subjects in the modification of accounting system in this department and to develop it and make it able to make available important and accurate information for the planning requirements and monetary and evaluation performance and to make decisions, besides to develop the performance of Iraqi Cultural departments working abroad and to render its role effective to serve the students of higher education in the progressive Countries to facility its growing in scientific and professional and technica

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Jan 30 2013
Journal Name
Al-kindy College Medical Journal
Using the Abbreviated Version of Modification of Diet in Renal Disease Formula as A Primary Estimate for the Prevalence of Undiagnosed Chronic Kidney Disease in Patients with Acute Stroke
...Show More Authors

Introduction: The association between acute stroke and
renal function is well known. The aim of this study is to
know which group of patients with acute stroke is more
likely to have undiagnosed Chronic Kidney Disease and
which risk factors are more likely to be associated with.
Methods:We studied 77 patients who were diagnosed to
have an acute stroke.Patients were selected between
April2011andJune 2011 using the " 4-variable
Modification of
Diet in Renal Disease Formula " which estimates
Glomerular Filtration Rate using four variables :serum
creatinine ,age ,race and gender.
Results :The study included 38 male and 39 females
patients ,aged (35-95) years. Glomerular Filtration Rate in
patients wi

... Show More
View Publication Preview PDF
Publication Date
Sun Mar 06 2011
Journal Name
Baghdad Science Journal
Studying of the optical properties of poly (vinyl alcohol) films using Aluminum sulphate as additive by measuring allowed direct transition energy gap
...Show More Authors

The change in the optical band gap and optical activation energy have been investigated for pure Poly (vinyl alcohol)and Poly (vinyl alcohol) doped with Aluminum sulphate to proper films from their optical absorption spectra. The absorption spectra were measured in the wave range from (200-700) nm at temperature range (25-140) 0C. The optical band gap (Eg) for allowed direct transition decrease with increase the concentration of Aluminum sulphate. The optical activation energy for allowed direct transition band gap was evaluated using Urbach- edges method. It was found that ?E increases with increasing the concentration of Al2 (SO4)3 and decreases when temperature increases.

View Publication Preview PDF
Crossref
Publication Date
Sun Mar 06 2016
Journal Name
Baghdad Science Journal
Investigation of the dielectric Properties of (PPAB) terminated by phenylenediamine doped by Na2[Fe(CN)5.NO].2H2O using Lumped equivalent circuit
...Show More Authors

The aim of this paper is to demonstrate the effect of Na2[Fe(CN)5.NO].2H2O impurity (0.1 M) concentration on the dielectrical properties of poly (P-Aminobenzaldehyde) terminated by pheneylenediamine in the frequency and temperature ranges (1-100)KHz and (283-348) K respectively.These properties include dissipation factor, series and parallel resistance, series and parallel capacitance, real and imaginary part of the dielectric constant, a.c conductivity and impedance (real and imaginary) part, that have been deduced from equivalent circuit. The investigation shows that adding Na2[Fe(CN)5.NO].2H2O as additive to the polymer lead to increase of the dielectric constant with increasing temperature and it is decreasing with increasing the freq

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Mar 30 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Comparative Evaluation of Using Intranasal Desmopressin, Parenteral Diclofenac or their Combination in the Management of Acute Renal Colic Pain in Iraqi Patients
...Show More Authors

         There is a suggestion that an antidiuretic hormone-induced decrease in diuresis might contribute to the rapid relief of the acute pain in renal colic. This study was designed to evaluate the efficacy of desmopressin nasal spray compared with diclofenac given intramuscularly in patients with acute renal colic. The study included 75 patients randomized into three different groups; group A received desmopressin (40 μg, nasal spray), group B diclofenac (75 mg) intramuscularly and group C, both desmopressin and diclofenac. Pain was assessed using a visual analogue scale (a 10-cm horizontal scale ranging from `no pain' to `unbearable pain') at baseline, 10, 20 and 30 min after administering t

... Show More
View Publication Preview PDF
Crossref (1)
Crossref