A statistical optical potential has been used to analyze and
evaluate the neutron interaction with heavy nuclei 197Au at the
neutron energy range (1-20 MeV). Empirical formulae of the optical
potentials parameters are predicted by using ABAREX Code with
minimize accuracy compared with experimental bench work data.
The total elastic, absorption, shape elastic and total compound crosssections are calculated for different target nuclei and different
incident neutron energies to predict the appropriate optical
parameters that suit the present interaction. Also the dispersion
relation linking between real and imaginary potential is analyzed
with more accuracy. The results indicate the behavior of the
dispersion contribution in imaginary potential has a parabolic change
about the Fermi surface energy while in the real potential it fall with
increasing the neutron energy. Good agreements have been achieved
with the available experimental data
Cadmium Oxide and Bi doped Cadmium Oxide thin films are prepared by using the chemical spray pyrolysis technique a glass substrate at a temperature of (400?C) with volumetric concentration (2,4)%. The thickness of all prepared films is about (400±20) nm. Transmittance and Absorbance spectra are recorded in the wave length ranged (400-800) nm. The nature of electronic transitions is determined, it is found out that these films have directly allowed transition with an optical energy gap of (2.37( eV for CdO and ) 2.59, 2.62) eV for (2% ,4%) Bi doped CdO respectively. The optical constants have been evaluated before and after doping.
The effect of 0.662MeV gamma radiation on the optical properties of the CdTe thin films was studied. 300nm thickness of CdTe samples were irradiated with doses (10, 20, 30,60krad) in room temperature. The absorption spectra for all the samples were recorded using UV- Visible spectrometer in order to calculate the energy gap, width of localized states and optical constants(refractive index, extinction coefficient, real and imaginary parts of dielectric constant). The optical energy gap was found to decrease from (1.53 to 1.48 eV), while the width of localized states increased from (1.34 to 1.49 eV) with the increasing of radiation dose. The behavior of energy gap with the irradiation dose makes the material a good candidate for dosimetry
... Show Morecurrent research Cares about study patterns of optical and aesthetic values in the halls of occasions (weddings) because of their importance in providing an atmosphere of joy. The problem was through the study of light and its impact on the receiver and found a researcher that interior spaces allocated to the halls inappropriate in terms of functional and aesthetic so necessitated the need to study this phenomenon in order to be addressed through the study of light and its impact on the users of those spaces where research aims to current detection properties patterns optical in the internal spaces of the halls and identify some of the aesthetic values of the lighting for the interior spaces.The search consists of four chapters, the firs
... Show MoreAbstract:
The research aims to identify how to audit potential liabilities and contingent liabilities in light of the pandemic and its reflection on the auditor's report. The research problem is represented by the complexity of the process of checking potential liabilities and contingent liabilities in insurance companies, which was negatively reflected in the auditor's neutral technical opinion. The researchers hypothesize that auditing potential liabilities and contingent liabilities in light of the Corona pandemic is positively reflected in the auditor's report. The research concludes that the process of checking potential liabilities and contingent liabilities is
... Show MoreThe current study aims to investigate the effect of the interaction between the use of the improve strategy in teaching mathematics and the level of academic achievement on the acquisition of algebraic concepts and habits of mind among tenth-grade students in Oman. The study adopted the experimental method, based on a quasi-experimental design with two groups: experimental and control groups and pre-post-measurement. The study sample consisted of (28) 10th-grade students as an experimental group and 26 of 10th-grade students as a control group in Al-Tufail bin Amr School in South Al Batinah. The differences in the pretest and posttest gains were analyzed using mean, standard deviation, ANCOVA, t-test, effect size (eta-square), and two-wa
... Show MoreAbstract: Reflection optical fibre Humidity sensor is presented in this work, which is based on no core fibre prepared by splicing a segment of no core fibre (NCF) at different lengths 1-6 cm with fixed diameter 125 µm and a single mode fibre (SMF). The range of humidity inside the chamber is controlled from 30% to 90% RH at temperature ~ 30 °С. The experimental result shows that the resonant wavelength dip shift decreases linearly with an increment of RH% and the sensitivity of the sensor increased linearly with an increasing in the length of NCF. However, a high sensitivity 716.07pm/RH% is obtained at length 5cm with good stability and reputability. Furthermore, the sensor is shif
... Show MoreHealthcare professionals routinely use audio signals, generated by the human body, to help diagnose disease or assess its progression. With new technologies, it is now possible to collect human-generated sounds, such as coughing. Audio-based machine learning technologies can be adopted for automatic analysis of collected data. Valuable and rich information can be obtained from the cough signal and extracting effective characteristics from a finite duration time interval that changes as a function of time. This article presents a proposed approach to the detection and diagnosis of COVID-19 through the processing of cough collected from patients suffering from the most common symptoms of this pandemic. The proposed method is based on adopt
... Show MoreThe - mixing ratios of -transitions from levels in populated in the reactions are calculated in present work using - ratio, constant statisticalTensor and least squares fitting methods The results obtained are in general, in good agreement or consistent, within the associated uncertainties, with these reported in Ref.[9],the discrepancies that occurs are due to inaccuracy existing in the experimental data The results obtained in the present work confirm the –method for mixed transitions better than that for pure transition because this method depends only on the experimental data where the second method depends on the pure or those considered to be pure -transitions, the same results occur in – method