Preferred Language
Articles
/
ijp-403
Radiation doses assessment for workers on radiation measuring devices response check in RNSD laboratories
...Show More Authors

Radiation measuring devices need to periodic calibration process to examine their sensitivity and the extent of the response. This study is used to evaluate the radiation doses of the workers in the laboratories of the Directorate of Safety as a result of the use of point sources in calibrating of the devices in two ways, the first is the direct measurement by the FAG device and the others using RESRAD and RAD PRO programs. The total doses values using FAG were (2.57 μSv/y, 102.3 μSv/y and 20.75 μSv/y for TLD laboratory, Gamma spectroscopy analyses (GSA) laboratory and equipment store respectively, and the total doses that calculated using RESRAD and RAD PRO were 1.518 μSv/y, 76.65 μSv/y and 21.2 μSv/y for the above laboratories. the dose rate is very low compare with the national, international dose rate limits (20 mSv/y).

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Jun 27 2021
Journal Name
Iraqi National Journal Of Nursing Specialties
Prevalence of Smoking among Health Workers and Effectiveness of Instructional Booklet concerning Risks of Smoking on Health Workers′ Knowledge in Baghdad Teaching Hospital
...Show More Authors

Objective(s): The present study aims at assessing the prevalence of smoking among health workers in Baghdad Teaching Hospital and to find out the effectiveness of instructional booklet concerning risk of smoking on health workers′ knowledge in hospital.

Methodology: A pre-experimental design study was conducted from 1st of October 2019 to 17th of March 2020. A non-probability sample consists of (500) participant (343 non-smokers and 157 smokers) from (1500) health workers in Baghdad Teaching Hospital, they included the physicians, nurses, pharmacists, physiotherapists, Laboratory Technicians, Medical Assistants. A questionnaire is constructed to evaluate the effectiveness of instructional booklet on health workers’ knowledge

... Show More
View Publication Preview PDF
Publication Date
Sat Dec 05 2015
Journal Name
PrzeglĄd Elektrotechniczny
Power Amplifier Frequency Controller Using feedback control techniques for Bio-implanted Devices
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Tue Jul 07 2020
Journal Name
Journal Of Mechanical Engineering Research & Developments
Occupational noise and its effects on Baghdad airport workers
...Show More Authors

The problem of noise in the Baghdad airport has been examined in this study; and noise measurement and survey studies have been carried out at four high noise level (operation, training and development, quality system, and information and technology) zones located in this region. Noise exposure is a common hazard to workforce in general although at varying degrees depending on the occupation, as many workers are exposed for long periods of time to potentially hazardous noise. A questionnaire was completed by 122 workers during this study in order to determine the physical, physiological, and psycho-social impacts of the noise on workers and to specify what kind of measurements have been taken both by the employers and workers for protection

... Show More
View Publication Preview PDF
Publication Date
Fri Feb 14 2020
Journal Name
Journal Of Mechanical Engineering Research And Developments
Occupational Noise and Its Effects on Baghdad Airport Workers
...Show More Authors

The problem of noise in the Baghdad airport has been examined in this study; and noise measurement and survey studies have been carried out at four high noise level (operation, training and development, quality system, and information and technology) zones located in this region. Noise exposure is a common hazard to workforce in general although at varying degrees depending on the occupation, as many workers are exposed for long periods of time to potentially hazardous noise. A questionnaire was completed by 122 workers during this study in order to determine the physical, physiological, and psycho-social impacts of the noise on workers and to specify what kind of measurements have been taken both by the employers and workers for protection

... Show More
Publication Date
Thu Jun 23 2022
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Effect of Curcumin at Various Doses on the Pharmacokinetic Profile of Tacrolimus in Healthy Rabbits
...Show More Authors

The purpose of present study is to evaluate the effect of co-administration of curcumin (CUR) at various doses on the pharmacokinetic (PK) profile of tacrolimus (TAC), a CYP 3A4 substrate in healthy male rabbits. Healthy male rabbits (n=18) were employed in an in vivo, parallel-randomized study. Three groups of rabbits were selected and separated: The rabbits in the first group (control group) received 1 mg/kg TAC orally. Blood samples (1.5-2 mL) were drawn from rabbits' ear marginal veins at the following time frames:  15.0, 30.0, 45.0, 60.0, 90.0, 120.0, 150.0, 180.0 and 300 minutes after TAC administration post dosing and analyzed by using a TAC chemiluminescent enzyme immunoassay (CLIA) detection kit. In the second and third gro

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Crossref
Publication Date
Tue Oct 29 2024
Journal Name
Journal Of Advanced Pharmacy Education And Research
Evaluating the effects of different doses of fimasartan on methotrexate-induced renal inflammation in rats
...Show More Authors

The nephrotoxicity induced by methotrexate is a severe condition that greatly affects its therapeutic potential and has a significant inflammatory component. Fimasartan is an angiotensin receptor blocker that offers organ-protective effects and may be useful in mitigating renal injury. The present study explored the anti-inflammatory potential of two doses of fimasartan against methotrexate-mediated nephrotoxicity. Albino rats were intraperitoneally administered a single methotrexate (20 mg/kg). Intraperitoneal treatment with fimasartan (5 or 10 mg/kg/day) was initiated on day two after methotrexate injection and continued for seven consecutive days. Methotrexate significantly increased serum urea, creatinine, and NGAL concentrations. It al

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Mon Oct 01 2012
Journal Name
Iraqi Journal Of Physics
Double probe for measuring the plasma parameters
...Show More Authors

In this work the diode planer magnetron sputtering device was
designed and fabricated. This device consists of two aluminum discs
(8cm) diameter and (5mm) thick. The distance between the two
electrodes is 2cm, 3cm, 4cm and 5cm.
Design and construction a double probe of tungsten wire with
(0.1mm) diameter and (1.2mm) length has been done to investigate
electron temperature, electron and ion density under different
distances between cathode and anode. The probes were situated in
the center of plasma between anode and cathode.
The results of this work show that, when the distance between
cathode and anode increased, the electron temperature decreased.
Also, the electron density increases with the increasing

... Show More
View Publication Preview PDF
Publication Date
Wed Jan 01 2020
Journal Name
Asian Journal Of Ournal Of Chemistry
Assessment of an Electrocoagulation Reactor for the Removal of Oil Content and Turbidity from Real Oily Wastewater Using Response Surface Method
...Show More Authors

Background: Large amounts of oily wastewater and its derivatives are discharged annually from several industries to the environment. Objective: The present study aims to investigate the ability to remove oil content and turbidity from real oily wastewater discharged from the wet oil's unit (West Qurna 1-Crude Oil Location/ Basra-Iraq) by using an innovated electrocoagulation reactor containing concentric aluminum tubes in a monopolar mode. Methods: The influences of the operational variables (current density (1.77-7.07 mA/cm2) and electrolysis time (10-40 min)) were studied using response surface methodology (RSM) and Minitab-17 statistical program. The agitation speed was taken as 200 rpm. Energy and electrodes consumption had been studi

... Show More
Preview PDF
Crossref (13)
Crossref
Publication Date
Mon Aug 26 2024
Journal Name
Jbpml
Studying The Changes in Motility and Morphology on Human sperm after exposure to low doses of x-rays
...Show More Authors

the energy that a radiation source emits as light (photons), electromagnetic waves, or particles is known as radiation. X-ray is one type of ionizing radiation that falls within the electromagnetic wave category of short wavelengths. Because of their short wavelength. X-ray is a type of ionizing radiation that is used in a constantly growing number of diagnostic procedures. X-ray diagnostic imaging has been employed in the medical field for more than a century(Hariyoto et al., 2020). Radiation has advantages for human health, but there is also a risk. the impacts of Radiation on Fertility it is an oligospermia, or a reduction in the number of sperm cells, which is already possible after radiation exposure of 0.15 mGy. It Leads to impede

... Show More
Publication Date
Tue Dec 15 2020
Journal Name
Al-academy
The Formal Organization in Internal Spaces of Medical Laboratories: نور عامر علي-فاتن عباس لفته
...Show More Authors

تشغل الفضاءات الداخلية الطبية اهتمام واسع , لما توفره من رعاية صحية للمرضى ,فلابد ان يُهتَمْ بها من الجانب الوظيفي(الادائي), لتحقيق الراحة البصرية والنفسية والجسدية لغرض الوصول الى الاداء الجيد للكادر الطبي, ولهذا وجد ضرورة التعرف على تلك الفضاءات الداخلية بشكل اعمق , وهل انها ملاءمة للمرتكزات التصميمية المتعارف عليها؟ , لذلك تم تسليط الضوء على الفضاءات الداخلية للمختبرات الطبية, وقد تناول البحث المشكلة واه

... Show More
View Publication Preview PDF
Crossref