Preferred Language
Articles
/
ijp-3
Spectroscopic study the plasma parameters for Pb doped CuO prepared by pulse Nd:YAG laser deposition
...Show More Authors

In this work, plasma parameters such as, the electron temperature )Te(, electron density ne, plasma frequency )fp(, Debye length )λD(
and Debye number )ND), have been studied using optical emission spectroscopy technique. The spectrum of plasma with different values of energy, Pb doped CuO at different percentage (X=0.6, 0.7, 0.8) were recorded. The spectroscopic study for these mixing under vacuum with pressure down to P=2.5×10-2 mbar. The results of electron temperature for X=0.6 range (1.072-1.166) eV, for X=0.7 the Te range (1.024-0.855) eV and X=0.8 the Te is (1.033-0.921) eV. Optical properties of CuO:Pb thin films were determined through the optical transmission method using ultraviolet visible spectrophotometer within the range (190 – 1100) nm.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Apr 07 2021
Journal Name
Indian Journal Of Forensic Medicine & Toxicology,
The Clinical Effect of Super Oxidized Water Mouthwash on The Periodontal Parameters (Plaque Index, Gingival Index And Bleeding on Probing) for Patients with Dental Biofilm Induced Gingivitis
...Show More Authors

Publication Date
Sun Jan 01 2017
Journal Name
International Journal Of Latest Trends In Engineering And Technology
Study the effect of number of nozzle on optical and structural properties of sno2 films grown by (apcvd)
...Show More Authors

View Publication Preview PDF
Crossref
Publication Date
Sun Jun 30 2024
Journal Name
Iraqi Journal Of Science
Telescope Mirror Cleaning Using Atmospheric Pressure Multi-Channel Radio Frequency Plasma Jet
...Show More Authors

     In this work, the surface of the telescope’s mirror is cleaned using an atmospheric-pressure radio frequency plasma jet (APRFPJ), which is generated by Argon gas between two coaxial metal electrodes. The RF power supply is set to 2 MHz frequencies with three different power levels: 20, 50, and 80 W. Carbon, that has adhered to the surface, can be effectively removed using the plasma cleaning technique, which also modifies any residual bonds. The cleaned surface was clearly distinguished using an optical emission spectroscopy (OES) technique and a water contact angle (WCA) analyzer for the activation property on their surfaces. The sample showed a super hydrophilic surface at an angle of 1° after 2.5 minutes of plasma tre

... Show More
View Publication
Scopus (1)
Scopus Crossref
Publication Date
Wed Sep 11 2019
Journal Name
Aip Conference Proceedings
Estimation of shock wave position in plasma plume using Sedov-Taylor model
...Show More Authors

In this work, radius of shock wave of plasma plume (R) and speed of plasma (U) have been calculated theoretically using Matlab program.

Publication Date
Sat Dec 01 2018
Journal Name
Annals Of Medicine And Surgery
Plasma d-dimer level correlated with advanced breast carcinoma in female patients
...Show More Authors

View Publication
Scopus (10)
Crossref (10)
Scopus Crossref
Publication Date
Mon Jun 15 2020
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of plasma treatment on some surface properties of acrylic resin polymer
...Show More Authors

Background: Polymer surfaces usually present problems in bonding and finishing due to their low hydrophilicity. The aim of this study is to investigate the effect of plasma treatment with the use of two types of gases (oxygen and argon) on surface roughness, and chemical surface properties of acrylic resin denture base polymer material. Materials and Methods: Three heat cured acrylic resin specimens of (2*8*30 mm) dimensions were prepared for each test carried out in this study. Two tests were conducted, surface roughness test and chemical surface analysis test. Results: Application of plasma treatment increased surface roughness for both oxygen and argon plasma treated acrylic resin specimen groups compared with control untreated group,

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (1)
Scopus Crossref
Publication Date
Sat May 01 2021
Journal Name
Key Engineering Materials
Effect of Cold Plasma on the Levels Mineral Blood Components <i>In Vivo</i>
...Show More Authors

This study illustrates effect of cold plasma CAP on the mineral blood components in vivo. the mineral blood component (Ca, Na, Cl, K and Fe) are used. Floating Electrode-Dielectric Barrier Discharge (FE-DBD) system of probe diameter 4cm is used for this purpose, and variable voltage (0-20) kV and variable frequency (0-30) kHz, the output power was ranged from (10 - 70) W. the effect of cold atmospheric plasma on mineral blood is studied with different exposure durations (30,45,60) sec. As the plasma exposure duration increases, the calcium, potassium and iron components in the blood increased, while The sodium and chlorine elements decreased. These results give an indication of the cold plasma receptor to be used to treat many disea

... Show More
View Publication
Scopus (3)
Crossref (2)
Scopus Crossref
Publication Date
Sun Sep 25 2022
Journal Name
Hiv Nursing
BIOSYNTHESIS OF SILVER / SILVER CHLORIDE NANOPARTICLES BY IRAQI PROPOLIS AND STUDY THE ANTI – BACTERIAL ACTIVITY
...Show More Authors

Sliver / Sliver chloride is as old used from human but the sliver / sliver chloride nanoparticles have only recently been recogenized. They have used in medicin and agiculture. In the present study have been investigation the effecte biosynthesis Sliver / Sliver chloride nanoparticles as antibacterial by demonstrated that Ag / AgCl NPs arrest the growth of many bacterial: S.typhimurium, k. pneumonia. S. aureus, L.monocytogenes, B. Anthracis, E. coli, C. frundi, S. Pneumonia, P. Aeruginosa. The elements compestion and crystallization panal of biosynthesized nanoparticles were chracterazated by FTIR, XRD and SEM. From XRD, It is confirmed the synthesized nanoparticles contain Sliver / Sliver chloride elements. Synthesized Ag / AgCl NPs showed

... Show More
Publication Date
Wed Mar 30 2022
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Study the Optimization of Petroleum Refinery Wastewater Treatment by Successive Electrocoagulation and Electro-oxidation Systems
...Show More Authors

In this study, successive electrocoagulation (EC) and electro-oxidation (EO) processes were used to minimize some of the major pollutants in real wastewater, such as organics (detected by chemical oxygen demand (COD)), and turbidity. The wastewater utilized in the present study was collected from the Midland Refinery Company in Baghdad-Iraq. The performance of the successive batch EC-EO processes was studied by utilizing Graphite and Aluminum (Al) as monopolar anode electrodes and stainless steel (st.st.) as the cathode. The Taguchi experimental design approach was used to attain the best experimental conditions for COD reduction as a major response. Starting from chemical oxygen demand COD of (600 ppm), the effects of current density (C

... Show More
View Publication Preview PDF
Crossref (19)
Crossref
Publication Date
Wed Mar 30 2022
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Study the Optimization of Petroleum Refinery Wastewater Treatment by Successive Electrocoagulation and Electro-oxidation Systems
...Show More Authors

In this study, successive electrocoagulation (EC) and electro-oxidation (EO) processes were used to minimize some of the major pollutants in real wastewater, such as organics (detected by chemical oxygen demand (COD)), and turbidity. The wastewater utilized in the present study was collected from the Midland Refinery Company in Baghdad-Iraq. The performance of the successive batch EC-EO processes was studied by utilizing Graphite and Aluminum (Al) as monopolar anode electrodes and stainless steel (st.st.) as the cathode. The Taguchi experimental design approach was used to attain the best experimental conditions for COD reduction as a major response. Starting from chemical oxygen demand COD of (600 ppm), the effects of current densi

... Show More
View Publication Preview PDF
Crossref (19)
Crossref