The systems cooling hybrid solar uses solar collector to convert solar energy into the source of heat for roasting Refrigerant outside of the compressor and this process helps in the transformation of Refrigerant from the gas to a liquid state in two-thirds the top of the condenser instead of two-thirds the bottom of the condenser as in Conventional cooling systems and this in turn reduces the energy necessary to lead the process of cooling. The system cooling hybrid use with a capacity of 1 ton and Refrigerant type R22 and the value of current drawn by the system limits (3.9-4.2A), the same value of electric current calculated by the system are Conventional within this atmosphere of Iraq, and after taking different readings of the temperatures and pressure to several points in the system's found that the Refrigerant when it comes out of the compressor, it loses part of the temperature of the water in the solar collector through a heat exchanger while the literature published in accordance with the manufacturers that the solar collector, a kind of vacuum tubes contributes to raise the pressure and temperature of the fluid cooler to reduce the consumption of energy spent on compressor. Therefore, the system described by the current not fit for domestic use within the Iraqi environmental conditions.
Environmental Control Systems form one of the integral tasks of the designer, resulting from his/her acquaintance with the nature of sites and the way they are deployed to achieve modern space entity which is witnessing significant development in the field of interior design.Good deployment of these systems offer us, as designers, high potential and several varied solutions to configure internal spaces characterised as a fertile field of study and knowledge.The research problem was identified in the marginalisation of the importance of Environmental Control Systems as an important designing factor to achieve integrated design. The research problem was demonstrated in Chapter One, along with defining the objectives and formulating
The aim of this work is oriented to increase film cooling effectiveness value through numerical investigations for flow of Mach number not more than 0.3 around vane surface, to find the effects of inclination and compounds angles of round holes in staggered rows on adiabatic film cooling effectiveness of vane suction side. Multi cylindrical film cooling hole cases were studied with pitch ratio P/d =2 and 3, local blowing ratios M=0.382, 0.77 and 1.14, inclination angles a=30° and 45°, compound angles β= 0°, 15°, 30° and 45° and local momentum ratios I= 0.084, 0.34 and 0.756 for better cooling process.
A numerica
... Show MoreThe vast advantages of 3D modelling industry have urged competitors to improve capturing techniques and processing pipelines towards minimizing labour requirements, saving time and reducing project risk. When it comes to digital 3D documentary and conserving projects, laser scanning and photogrammetry are compared to choose between the two. Since both techniques have pros and cons, this paper approaches the potential issues of individual techniques in terms of time, budget, accuracy, density, methodology and ease to use. Terrestrial laser scanner and close-range photogrammetry are tested to document a unique invaluable artefact (Lady of Hatra) located in Iraq for future data fusion sc
The heat and mass transfer coefficients of the indirect contact closed circuit cooling tower, ICCCCT, were investigated experimentally. Different experiments were conducted involving the controlling parameters such as air velocity, spray water to air mass flow rate ratio, spray water flow rate, ambient air wet bulb temperature and the provided heat load to investigate their effects on the performance of the ICCCCT. Also the effect of using packing on the performance of the ICCCCT was investigated. It was noticed that these parameters affect the tower performance and the use of packing materials is a good approach to enhance the performance for different operational conditions. Correlations for mass and heat transfer coefficients are pres
... Show MoreThe security of information represent the available protection of information and its component and guaranty the its safety and confidentiality. The absent or lack or stop of security of information and without maximum benefit may lead to lose confidence and make it burden on the company. So we must protect the company and information from the damages which may lead to the frailer of performance and loses of the company and its workers. So the security of information considered one of the potential and controlling basis to protect individuals and companies from the damages. To insure the security and confidentiality of information there are delicate, proper and trusted ways, like FIRE WALL, PASS WORD, SYPHAR
... Show MoreBackground: Acute appendicitis is regarded as one of the most common inflammation that needs surgical intervention. Different scoring systems have been used for diagnosing of acute appendicitis. ALVARADO score is one of the most widely used score in diagnosing of acute appendicitis, but the accuracy of the latter is insufficiently low in Middle-East patients. Thus a new scoring system called RIPASA score has been designed for diagnosing of acute appendicitis in those patients. The aim of this study is to use RIPASA score and compare its result with ALVARADO score in diagnosing of acute appendicitis.
Subjects and Methods: The study includes 200 patients with symptoms and signs of
... Show More