The systems cooling hybrid solar uses solar collector to convert solar energy into the source of heat for roasting Refrigerant outside of the compressor and this process helps in the transformation of Refrigerant from the gas to a liquid state in two-thirds the top of the condenser instead of two-thirds the bottom of the condenser as in Conventional cooling systems and this in turn reduces the energy necessary to lead the process of cooling. The system cooling hybrid use with a capacity of 1 ton and Refrigerant type R22 and the value of current drawn by the system limits (3.9-4.2A), the same value of electric current calculated by the system are Conventional within this atmosphere of Iraq, and after taking different readings of the temperatures and pressure to several points in the system's found that the Refrigerant when it comes out of the compressor, it loses part of the temperature of the water in the solar collector through a heat exchanger while the literature published in accordance with the manufacturers that the solar collector, a kind of vacuum tubes contributes to raise the pressure and temperature of the fluid cooler to reduce the consumption of energy spent on compressor. Therefore, the system described by the current not fit for domestic use within the Iraqi environmental conditions.
In this study, the effect of the thermal conductivity of phase change material (PCM) on the performance of thermal energy storage has been analyzed numerically. A horizontal concentric shell-and-tube latent heat thermal energy storage system (LHTESS) has been performed during the solidification process. Two types of paraffin wax with different melting temperatures and thermal conductivity were used as a PCM on the shell side, case1=0.265W/m.K and case2=0.311 W/m.K. Water has been used as heat transfer fluid (HTF) flow through in tube side. Ansys fluent has been used to analyze the model by taking into account phase change by the enthalpy method used to deal with phase transition. The numerical simulatio
... Show MoreA field experiment was conducted in an agricultural field in Al-Hindia district, Karbala governorate in a silty clay soil during the year 2020. The research included a study of two factors, the first is the depth of plowing at two levels, namely 13 and 20 cm, which represented the main blocks. The second is the tire inflation pressure at two levels, namely (70 and 140 kPa), which represented the secondary blocks. Slippage percentage, field efficiency, leaf area, and 300 grain weight were studied. The experiment was carried out using a split-plot system under a Randomized complete block design, at three replications. The tillage depth of 13 cm exceeds/transcend by giving it the least slippage of (11.01%), the highest field efficiency of (50.
... Show MoreNanoparticles of Pb1-xCdxS within the composition of 0≤x≤1 were prepared from the reaction of aqueous solution of cadmium acetate, lead acetate, thiourea, and NaOH by chemical co-precipitation. The prepared samples were characterized by UV-Vis spectroscopy(in the range 300-1100nm) to study the optical properties, AFM and SEM to check the surface morphology(Roughness average and shape) and the particle size. XRD technique was used to determine the crystalline structure, XRD technique was used to determine the purity of the phase and the crystalline structure, The crystalline size average of the nanoparticles have been found to be 20.7, 15.48, 11.9, 11.8, and 13.65 nm for PbS, Pb0.75Cd0.25S,
... Show MoreThe telecommunications industry has gone through series of development efforts to provide quality services to their consumers. Generally, telecommunication industry provides two main services such as telephony and internet which involved customer registration, billing and payment. However, the challenge confronting telecommunications industry is to meet the customer satisfaction in the billing system such as accuracy, easy to understand and unambiguous billing issue. In order to develop Customer Billing Telephony System,a user experience study is conducted to gather the user requirements. Hence, the CBTS was developed that takes into consideration user’s value experience that provides a support for managing and monitoring billing proce
... Show MoreThis investigation is a study of the length of time where drops can exist at an oil-water interface before coalescence take place with a bulk of the same phase as the drops. Many factors affecting the time of coalescence were studied in is investigation which included: dispersed phase flow rate, continuous phase height, hole size in distributor, density difference between phases, and viscosity ratio of oil/water systems, employing three liquid/liquid systems; kerosene/water, gasoil/water, and hexane/water. Higher value of coalescence time was 8.26 s at 0.7ml/ s flow rate, 30cm height and 7mm diameter of hole for gas oil/water system, and lower value was 0.5s at 0.3ml/s flow rate, 10 cm height and 3mm diameter of hole for hexane
... Show MoreThe growing demand for energy, coupled with the continued dominance of fossil fuels as the primary energy source, necessitates eco-friendly technologies that simultaneously enhance oil recovery (EOR) and reduce the impact of their emissions. Only one task, which is the CO2-EOR project, can combine these two sustainable development goals. Further, employing green nanotechnology, including nanoparticles and nanofluids, ensures a sustainable approach to controlling and enhancing rock wettability, thereby enhancing hydrocarbon production and carbon storage. However, the performance of nanofluids in subsurface formations is limited by the stability of these nano-dispersions at the harsh conditions of reservoirs. This work thus synthesize
... Show More