Preferred Language
Articles
/
ijp-36
Spectroscopic analysis of magnesium-aluminum alloys by laser induced breakdown spectroscopy
...Show More Authors

In this work, the spectra of plasma glow produced by Nd:YAG laser operated at 1.064 μm on Al-Mg alloys with same molar ratio samples in air were analyzed by comparing the atomic lines of aluminum and magnesium with that of strong standard lines. The effect of laser energies on spectral lines, produced by laser ablation, were investigated using optical spectroscopy, the electron density was measured utilizing the Stark broadening of magnesium-aluminum lines and the electron temperature was calculated from the standard Boltzmann plot method. The results that show the electron temperature increases in magnesium and aluminum targets but decreases in magnesium: aluminum alloy target, also show the electron density increase all the aluminum, magnesium and mix both them, It was found that the lines intensities at different laser peak powers increase when the laser peak power increases then decreases when the power continues to increase.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Feb 04 2019
Journal Name
Iraqi Journal Of Physics
Gamma ray effect on the properties of R590 and C480 laser dyes
...Show More Authors

In the current research, we investigated the absorption spectrum for R590 and C480 dyes in ethanol solvent for different dye solution concentrations of 10-4, 10-5 and 10-6M. These dyes have been prepared and studied before and after gamma irradiation (first, second ionization) using cesium-137 source with absorbed doses of 18.36 Gy (time exposure of 10 days) and 73.44 Gy (with time exposure of 40 days). We noticed that the absorption intensity was decreased with decreasing concentration, before gamma irradiation while the absorption spectrum peak shifted towards the short wavelength (blue shift). It was also found that the intensity of absorption spectrum increased and shifted the absorption spectrum peak towards the long wavelength (red

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Oct 29 2022
Journal Name
International Ophthalmology
Comparison of corneal flap thickness predictability and architecture between femtosecond laser and sub-Bowman keratomileusis microkeratome in laser in situ keratomileusis
...Show More Authors

View Publication
Scopus (4)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Sun Sep 07 2014
Journal Name
Baghdad Science Journal
Design and study for transmitter system of laser Nd-YAG (1.06 ?m)
...Show More Authors

In this research , design and study a (beam expander) for the Nd – YAG laser with (1.06 ?m) Wavelength has been studied at 5X zoom with narrow diversion in the room temperature. by using (ZEMAX) to study the system. Evaluate its performance via (ZEMAX) outputs, as bright Spot Diagram via (RMS), Ray Fan Plot, Geometric Encircled Energy and the value of Focal shift. Then study the effect of field of view on the outputs in the room temperature.

View Publication Preview PDF
Crossref
Publication Date
Mon Nov 30 2020
Journal Name
Iraqi Geological Journal
EXPERIMENTAL STUDY OF MICRO SILICA BEHAVIOR AND ITS EFFECT ON IRAQI CEMENT PERFORMANCE BY USING X-RAY FLUORESCENCE ANALYSIS
...Show More Authors

The cement slurry is a mixture of cement, water and additives which is established at the surface for injecting inside hole. The compressive strength is considered the most important properties of slurry for testing the slurry reliability and is the ability of slurry to resist deformation and formation fluids. Compressive strength is governed by the sort of raw materials that include additives, cement structure, and exposure circumstances. In this work, we use micro silica like pozzolanic materials. Silica fume is very fine noncrystalline substantial. Silica fume can be utilized like material for supplemental cementations for increasing the compressive strength and durability of cement. Silica fume has very fine particles size less

... Show More
View Publication
Crossref
Publication Date
Wed Jun 28 2023
Journal Name
Engineering Applications Of Computational Fluid Mechanics
Comprehensive analysis of melting enhancement by circular Y-shaped fins in a vertical shell-and-tube heat storage system
...Show More Authors

View Publication
Scopus (44)
Crossref (21)
Scopus Clarivate Crossref
Publication Date
Thu Mar 30 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Quantitative and Qualitative Analysis of Plumbagin in the Leaf and Root of Plumbago europaea Growing Naturally in Kurdistan by HPLC
...Show More Authors

Plumbago (Plumbaginaceae) is a genus of 10-20 species of flowering plants used in traditional Indian medicine, native to warm temperature to tropical regions of the world. The roots of Plumbago europaea, the Iraqi species of Plumbago, have been used for the treatment of cancer, rheumatoid arthritis, and dysmenorrhea. The main active constituents from dried powdered leaves and roots of Plumbago europaea were extracted by Soxhlet apparatus using ethyl acetate, the main active constituent was characterized by spectroscopic analysis (IR, 1H NMR, and 13C NMR)   as plumbagin. Quantitative and qualitative study of plumbagin in the roots and leaves extracts was carried out by HP

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Tue Jan 11 2022
Journal Name
3rd International Scientific Conference Of Alkafeel University (iscku 2021)
Elimination of the broadening in X-ray diffraction lines profile for nanoparticles by using the analysis of diffraction lines method
...Show More Authors

In this research, the results of the Integral breadth method were used to analyze the X-ray lines to determine the crystallite size and lattice strain of the zirconium oxide nanoparticles and the value of the crystal size was equal to (8.2nm) and the lattice strain (0.001955), and then the results were compared with three other methods, which are the Scherer and Scherer dynamical diffraction theory and two formulas of the Scherer and Wilson method.the results were as followsScherer crystallite size(7.4nm)and lattice strain(0.011968),Schererdynamic method crystallite size(7.5 nm),Scherrer and Wilson methodcrystallite size( 8.5nm) and lattice strain( 0.001919).And using another formula for Schearer and Wilson methodwe obtain the size of the c

... Show More
View Publication
Scopus (4)
Crossref (3)
Scopus Crossref
Publication Date
Mon Jun 04 2018
Journal Name
Baghdad Science Journal
Laser Densification of Prepared SiO2 Sol-Gel Thin Films
...Show More Authors

SiO2 nanostructure is synthesized by the Sol-Gel method and thin films are prepared using dip coating technique. The effect of laser densification is studied. X-ray Diffraction (XRD), Fourier Transformation Infrared Spectrometer (FTIR), and Field Emission Scanning Electron Microscopy (FESEM) are used to analyze the samples. The results show that the silica nanoparticles are successfully synthesized by the sol-gel method after laser densification. XRD patterns show that cristobalite structure is observed from diode laser (410 nm) rather than diode laser (532 nm). FESEM images showed that the shape of nano silica is spherical and the particles size is in nano range (? 100 nm). It is concluded that the spherical nanocrystal structure of silica

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Fri Feb 08 2019
Journal Name
Iraqi Journal Of Laser
Treatment of Spider Veins Using 810 nm Diode Laser
...Show More Authors

Spider veins are a common aesthetic problem mainly in females , the conventional method of treatment is by microsclerotherapy (injections) but laser therapy has become increasingly efficacious and a convenient method for treatment. The present study was performed to investigate the effectiveness and safety of pulsed diode laser (810nm) by doing thermal photocoagulation. Ten patients with lower limbs spider veins were included in this prospective study. They were treated with a repetitive pulsed diode laser in non contact technique using the following laser parameters (wave length 810nm,power 1 W ,pulse duration 0.1 s., pulse interval 0.5 s, spot diameter 4mm ,power density 7.9 W/cm2). Laser therapy was performed on day zero and day fourt

... Show More
View Publication Preview PDF
Publication Date
Sun Jun 01 2014
Journal Name
Baghdad Science Journal
(?m 10.6) Design study for Reserve of laser CO2
...Show More Authors

In this paper , the CO2 laser receiver system is designed and studied, with wavelength laser 10.6 ?m in room temperature , and to evaluate the performance and discussion it via the package of optical design (ZEMAX), from its output the Spot Diagram is measured through RMS ,and from the Ray fan plot , the aberrations is found which is the normal error for the best focus named (under corrected ) , the other output was the Geometric Encircled Energy in the spot diagram . and found that the radius of spot diagram at 80% (R80%) from the total energy ,and focal shift .The designed system have high efficiency and low cost .

View Publication Preview PDF
Crossref