Preferred Language
Articles
/
ijp-343
The evaluation of left ventricle stiffness index in patients suffering from hypertension
...Show More Authors

Many diseases can produce cardiac overload, of these disease hypertension, valve disease congenital anomaly in addition to many other disease. One of the most common diseases causing left ventricle overload is hypertension. A long term hypertension can cause myocardium hypertrophy leading to changes in the cardiac contractility and reduced efficiency. The investigations were carried out using conventional echocardiography techniques in addition to the tissue Doppler imaging (TDI) from which many noninvasive measurements can be readily obtained. The study has involved the effect of hypertension on the myocardium stiffness index through the measurement of early diastolic filling (E) and the early velocity of lateral mitral annulus (Ea) from which left ventricle filling pressure can be obtained. Our aim was to investigate the changes in the myocardium index of diastolic stiffness using TDI for patients suffering from systemic hypertension. We studied 263 hypertensive patients (105 males and 158 females of average age of 54.07± 12.7) and 166 healthy subjects (age range 40.06± 12.8,53 males and 113 females) as a control group. Measurements were carried out using tissue Doppler imaging (TDI) of the mitral annulus in addition to other echocardiographic measurements for the assessment of  left ventricle end diastolic dimension (LVEDD), Doppler peak early (E) and late (A) diastolic filling velocities. Results reveal that mitral annular early diastolic velocity (Ea) measured by TDI, that (Ea) was significantly lower for the hypertensive group in comparison with the control group (Ea 9.81 ± 2.87 cm/s for hypertensive vs. 12.90 ± 2.395 cm/s for control  p value <0.001. Hypertensive group also showed a significantly higher mitral annular late diastolic velocity (Aa) in comparison with control group as Aa 11.21 ± 2.504 cm/s for hypertensive vs. 9.787 ±2.201cm/s for control, p value <0.001..  In conclusion, LV myocardial diastolic stiffness index is increased in hypertensive patients.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Jun 25 2021
Journal Name
Journal Of Basic And Clinical Physiology And Pharmacology
The association of FKBP5 polymorphism with asthma susceptibility in asthmatic patients
...Show More Authors
Abstract<sec id="j_jbcpp-2020-0450_abs_001"> <title>Objectives

Inhaled corticosteroids are the most effective controllers of asthma, although asthmatics vary in their response. FKBP51 is a major component of the glucocorticoid receptor which regulates its responses to corticosteroids. Therefore, the present study aims to identify the role of FKBP5 gene polymorphism in asthma susceptibility and corticosteroid resistance.

Methods

DNA was extracted from the blood of 68 asthmatic

... Show More
View Publication Preview PDF
Scopus (7)
Crossref (6)
Scopus Crossref
Publication Date
Tue Jan 01 2019
Journal Name
Plant Archives
The role of some cytokines in diabetic patients infected with toxoplasmosis
...Show More Authors

Toxoplasmosis is the term for infection and disease in man and animal caused by a parasite called Toxoplasma gondii. The more susceptible to infect with toxoplasmosis is the Diabetic patients, due to low level of immunity response. The aim of current study is to investigate the immune status of diabetes mellitus type 2. One hundred and seventy five samples of both diabetes mellitus type 2patients and controls which had been tested by ELISA technique to detect anti-Toxoplasma Abs (IgG and IgM). The positive toxoplasmosis samples were tested to detect the level of TNF alpha and MIG. Results for all samples clarified that seronegative for IgM antibodies while 53 (53%) diabetic patients were seropositive for IgG antibodies and for toxoplasmosis

... Show More
Scopus (2)
Scopus
Publication Date
Fri Nov 09 2018
Journal Name
Iraqi National Journal Of Nursing Specialties
Quality of Life in Schizophrenic Patients: The Relationship with Personal Characteristics
...Show More Authors

Objectives: The study aims to identify the quality of life level in schizophrenic patients and to find out the
relationships between the quality of life and some of personal characteristics for those patients with
schizophrenia.
Methodology: A descriptive correlation analytic design was used by using the assessment technique on sample
of 100 schizophrenic outpatients, who were selected purposively (non-probability sample) during the period
10/ 3/2013 - 1/ 12 /2013. The study was conducted on the schizophrenic patients in an out patient psychiatric
clinics at Ibn-Rushd; and Al-Rashad Psychiatric Teaching Hospital; Baghdad Teaching Hospital, and Al-Kadhimya
Teaching Hospital. Self administrative questionnaire was used

... Show More
View Publication Preview PDF
Publication Date
Thu Apr 18 2019
Journal Name
Al-kindy College Medical Journal
The state of Vitamin D in Iraqi Patients With Parkinson Disease
...Show More Authors

Background: A role for vitamin D deficiency in Parkinson disease (PD) has recently been suggested.

Objective:: To estimate the state of vitamin D in PD with an age-matched healthy control.

Type of the study: A case control study.

Method: The study randomly comparison of plasma 25-hydroxyvitamin D (25[OH] D) concentrations of collected samples in a clinical neurology department ward / Baghdad teaching hospital / Medical City and Parkinson disease movement disorder clinic. Participants were registered into the study from October 2015 to October 2016. We was study   serum vitamin D level in 40 consecutive patients with

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Thu Mar 30 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
The Effect of Atenolol on CK-MB Levels in Hypertensive Patients
...Show More Authors

Atenolol is one of beta-adrenergic receptor blocking agent. It is widely used for the treatment of hypertension as a selective antihypertensive drug. But long term usage of atenolol may cause one of the cardiovascular diseases like myocardial infarction. To prove the relationship between atenolol and cardiovascular disease, measurement of creatinekinase-MB as a diagnostic indicator in early and long term usage of this drug by hypertensive patients is recommended.  A comparative study was conducted in Al-Yarmouk Teaching Hospital–Emergency Department- on 30 hypertensive patients using atenolol. They were divided into (2) groups A and B according to the duration of the drug usage. Group A- (15) patients with a mean age (56

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Mar 01 2019
Journal Name
Optical Fiber Technology
Highly sensitive measurement of surrounding refractive index using tapered trench–assisted multicore fiber
...Show More Authors

View Publication
Scopus (18)
Crossref (15)
Scopus Clarivate Crossref
Publication Date
Fri Sep 21 2018
Journal Name
Materials Research Express
Geometries, electronic properties and stability of molybdenum and tungsten nitrides low-index surfaces
...Show More Authors

Motivated by the vital role played by transition metal nitride (TMN) composites in various industrial applications, the current study reports electronic properties, thermodynamic stability phase diagram, and vacancy formation energies of the plausible surfaces of NiAs and WC-type structures of δ3-MoN and δ-WN hexagonal phases, respectively. Low miller indices of various surface terminations of δ3-MoN and δ-WN namely, (100), (110), (111), and (001) have been considered. Initial cleaving of δ3-MoN bulk unit cell offers separate Mo and N terminations signified as δ3-MoN (100): Mo, δ3-MoN(100):N, δ3-MoN(111):Mo, δ3-MoN(111):Mo, and δ3-MoN(001):Mo. However, the (110) plane reveals mix-truncated with both molybdenum and nitrogen atoms i

... Show More
View Publication
Scopus (15)
Crossref (13)
Scopus Clarivate Crossref
Publication Date
Mon Jan 01 2018
Journal Name
Research Journal Of Pharmacy And Technology
Impact of Human Cytomegalovirus Infection associated with the expressed protein of mutated <i>BRCA1</i> gene in breast tissues from a group of Iraqi Female Patients with Breast Carcinoma
...Show More Authors

View Publication
Scopus (5)
Crossref (2)
Scopus Crossref
Publication Date
Wed Oct 10 2018
Journal Name
Commun.fac.sci.univ.ank.series A2-a3
ULTRAHIGH SENSITIVE REFRACTIVE INDEX SENSOR BASED ON TAPERED MULTICORE OPTICAL FIBER
...Show More Authors

The refractive index sensors based on tapered optical fiber are attractive for many industries due to sensing capability in a variety of application. In this paper, we proposed a refractive index sensor based on multicore fiber (MCF) sandwiched between two standard single mode fibers (SMF). The sensor consisting of three sections, SMF- MCF-SMF is structurally simple and can be easily produced by joining these parts. The MFC contains seven cores and these cores are surrounded by a single cladding. The sensing region is obtained by tapering the MCF section where the evanescent field is generated. The single mode propagating along the SMF is stimulated at the first joint and is coupled to the cladding modes. These modes interfere with the core

... Show More
Publication Date
Sun Dec 24 2017
Journal Name
Iraqi Journal Of Laser
All Fiber Chemical Liquids Refractive Index Sensor Based on Multimode Interference
...Show More Authors

A simple all optical fiber sensor based on multimode interference (MMI) for chemical liquids sensing was designed and fabricated. A segment of coreless fiber (CF) was spliced between two single mode fibers to buildup single mode-coreless-single mode (SCS) structure. Broadband source and optical signal analyzer were connected to the ends of SCS structure. De-ionized water, acetone, and n-hexane were used to test the performance of the sensor. Two influence factors on the sensitivity namely the length and the diameter of the CF were investigated. The obtained maximum sensitivity was at n-hexane at 340.89 nm/RIU (at a wavelength resolution of the optical spectrum analyzer of 0.02 nm) when the diameter of the CF reduced from 125 μm to 60 μ

... Show More
View Publication Preview PDF