Electric Quadrupole transitions are calculated for beryllium isotopes (9, 10, 12 and 14). Calculations with configuration mixing shell model usually under estimate the measured E2 transition strength. Although the consideration of a large basis no core shell model with 2ℏtruncations for 9,10,12 and14 where all major shells s, p, sd are used, fail to describe the measured reduced transition strength without normalizing the matrix elements with effective charges to compensate for the discarded space. Instead of using constant effective charges, excitations out of major shell space are taken into account through a microscopic theory which allows particle–hole excitations from the core and model space orbits to all higher orbits with 2ℏw excitations which are called core-polarization effects. The two body Michigan sum of three ranges Yukawa potential (M3Y) is used for the core-polarization matrix element. The simple harmonic oscillator potential is used to generate the single particle matrix elements of all isotopes considered in this work. The b value of each isotope is adjusted to reproduce the experimental matter radius, These size parameters of the harmonic oscillator almost reproduce all the root mean square (rms) matter radii for 9,10,12,14Be isotopes within the experimental errors. Almost same effective charges are obtained for the neutron- rich Be isotopes which are smaller than the standard values. The major contribution to the transition strength comes from the core polarization effects. The present calculations of the neutron-rich 12,14Beisotopes show a deviation from the general trends in accordance with experimental and other theoretical studies. The configurations arises from the shell model calculations with core-polarization effects reproduce the experimental B(E2) values.
Using an electrochemical polymerization technique at room temperature, poly nicotine amide (PNA) was produced from the monomer nicotine amide (NA) in aqueous solution. The structure of polymer layer generated on the stainless steel surface (316 L) (working electrode) is investigated by Fourier Transmission Infrared Region (FT-IR). The anti-corrosion activity of polymer coating on the stainless steel (SS 316 L) is investigated by electrochemical polarization in 0.20M solution of HCl at 293-323K. The graphene -modified polymer film-coated SS had greater protection efficiency (PE percent) when compared to Nano ZnO -modified polymer film-coated SS. For the corrosion process of SS 316 L, kinetic and thermo-dynamic parameters of activatio
... Show MoreObjective: To assess the role of tumour necrosis factor alpha level and genotyping in susceptibility to leishmaniasis.Method: The case-control study was conducted from March to July 2021 at Baqubah Teaching Hospital, Diyala, Iraq,and comprised patients of cutaneous leishmaniasis in group A and healthy controls in group B. The serum level andsingle nucleotide polymorphisms of tumour necrosis factor-alpha rs41297589 and rs1800629 were compared betweenthe groups. Data was analysed using SPSS 28.Results: Of the 150 subjects, there were 75(50%) in group A; 39(52%) males and 36(48%) females with mean age23.91±13.14 years. The remaining 75(50%) subjects were in group B; 38(50.7%) males and 37(49.3%) females withmean age 22.84±4.35 years.
... Show MoreIn this research a local adsorbent was prepared from waste tires using two-step pyrolysis method. In the carbonization process, nitrogen gas flow rate was 0.2L/min at carbonization temperature of 500ºC for 1h. The char products were then preceded to the activation process at 850°C under carbon dioxide (CO2) activation flow rate of 0.6L/min for 3h. The activation method produced local adsorbent material with a surface area and total pore volume as high as 118.59m2 /g and 0.1467cm3/g, respectively. The produced . local adsorbent (activated carbon) was used for adsorption of lead from aqueous solution. The continuous fixed bed column experiments were conducted. The adsorption capacity performance of prepared activated carbons in this work
... Show MoreTheoretical spectroscopic study of Beryllium Oxide has been carried out, Boltzmann distribution of P, Q and R branches in the range of (0<J<13) at temperature 4200K for (0-0) band for electronic transitions B1Σ+-A1Π and B1Σ-X1Σ. The Boltzmann distribution of these branches has a maximum values at equal J approximately while the values of relative population are different. For the B1Σ+- X1Σ+ transition the branch's lines extend towards lower wavenumber. This is because (Bv'-Bv") value is negative, i.e Bv'< Bv" For B1Σ+-A1Π
... Show MoreBackground: The quantity and the quality of available bone, influence the clinical success of dental implants surgery. Cone beam Computed tomography is an established method for acquiring bone images before performing dental implant. Cone beam computed tomography is an essential tool for treatment planning and post-surgical procedure monitoring, by providing highly accurate 3-D images of the patient's anatomy from a single, low-radiation scan which yields high resolution images with favorable accuracy. The aim of study is the Measurement of alveolar bone (height and buccolingual width) and density in the mandible among Iraqi adult subject using CBCT for assessment of dental implant site dimensions. Material and method: The study sample in
... Show MoreMultilevel models are among the most important models widely used in the application and analysis of data that are characterized by the fact that observations take a hierarchical form, In our research we examined the multilevel logistic regression model (intercept random and slope random model) , here the importance of the research highlights that the usual regression models calculate the total variance of the model and its inability to read variance and variations between levels ,however in the case of multi-level regression models, the calculation of the total variance is inaccurate and therefore these models calculate the variations for each level of the model, Where the research aims to estimate the parameters of this m
... Show MoreThe purpose of this research is to recognize the relationship between the dimensions of banking service quality and customer's satisfaction , through customer's evaluation of the level of service quality offered to them by Al – Rasheed bank. Also to determine the proportional importance of different dimensions of service quality. In addition to examine the relationship between banking service quality in its dimensions and customer's satisfaction. (150 ) samples were distributed among the bank customers , only (130 ) samples were collected and good for analysis.
The results were analyzed and examined the hypothesis through a group of statistical methods. The most important results is the positive evaluation of the ba
... Show More