Experimental study for the properties of Fe3O4 dusty plasma using the air in vacuum chamber system
...Show More Authors

In this work, we carried out an experimental study of thedusty
plasma by taking the dust material Fe3O4 with radius of the any grain
0.1μm - 0.5μm. In experiment we use air in the vacuum chamber
system under different low pressure (0.1-1) Torr. The results
illustrated that the present of dust particles in the air plasma did not
effect on Paschen minimum which is 0.5 without dust and with Fe3O4
dusty grains.
The effect of Fe3O4 dust particles on plasma parameters can be
notice in direct current system in glow discharge region. The plasma
parameters which were studied in this work represent plasma
potential, floating potential,electron saturation current, temperature
of the electron, the density of the (electron, ion), and Debye length.
The measurements of parameters are taken by four cylindrical probes
which diagnosed at distance 4cm from the diameter of the cathode in
Paschen minimum at pressure 0.5 Torr. The diameter profiles of
plasma parameters in the present of dust are non- uniform. Plasma
potential and the floating potential of probe becomes more negatively
when the dust immersed into plasma region. The electron density
increases in the present of dust particle which lead to decrease the
electron temperature and Debye length. The behavior of those
parameters shows the discharge current and discharge voltage
increases without dust while the discharge current and voltage
decreases when Fe3O4 dust particles embedded.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Jun 24 2025
Journal Name
Food And Bioprocess Technology
Classification of Apple Slices Treated by Atmospheric Plasma Jet for Post-harvest Processes Using Image Processing and Convolutional Neural Networks
...Show More Authors
Abstract<p>Apple slice grading is useful in post-harvest operations for sorting, grading, packaging, labeling, processing, storage, transportation, and meeting market demand and consumer preferences. Proper grading of apple slices can help ensure the quality, safety, and marketability of the final products, contributing to the post-harvest operations of the overall success of the apple industry. The article aims to create a convolutional neural network (CNN) model to classify images of apple slices after immersing them in atmospheric plasma at two different pressures (1 and 5 atm) and two different immersion times (3 and again 6 min) once and in filtered water based on the hardness of the slices usin</p> ... Show More
View Publication
Scopus (2)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Thu Mar 31 2016
Journal Name
Al-khwarizmi Engineering Journal
Experimental Study of the Performance of Compound Parabolic Concentrating Solar Collector
...Show More Authors

The design, construction and investigation of experimental study of two compound parabolic concentrators (CPCs) with tubular absorber have been presented. The performance of CPCs have been evaluated by using outdoor experimental measurements including the instantaneous thermal efficiency. The two CPCs are tested instantly by holding them on a common structure. Many tests are conducted in the present work by truncating one of them in three different levels. For each truncation the acceptance half angle (θc) was changed. Geometrically, the acceptance half angle for standard CPC is (26o). For the truncation levels for the other CPC 1, 2 and 3 the acceptance half angle were 20o, 26o and 5

... Show More
View Publication Preview PDF
Publication Date
Sun Mar 01 2020
Journal Name
Agricultural Engineering
Analysis of the Vacuum-Steam Defrosting Process of Plums Pre-Treated with Dehydrofreezing
...Show More Authors
Abstract<p>The research material was prune plums (<italic>Prunus domestica</italic> L.), subjected to osmotic pre-treatment, with variable process time parameters and osmotic solution concentration. Plums thus fixed were frozen and stored for 6 months. At even (monthly) intervals, the product was defrosted by the vacuum-steam method, using the s-p-p chamber, until the thermocouple indicated a temperature of 4ºC in the sample’s thermal center. In order to study the kinetics of phenomena occurring during the defrosting process, the chamber was equipped with a measuring system to enable measurement and recording of temperature changes in time in the geometric center of the sample, as w</p> ... Show More
Scopus (1)
Scopus Crossref
Publication Date
Wed Dec 01 2010
Journal Name
Iraqi Journal Of Physics
Effect of Furnace Vacuum Pressure on the Joining Strength of Alumina Bonded Kovar
...Show More Authors

Ceramic to metal joining technique, which was used in this investigation includes the use of active filler alloy as a sandwich between the alumina and kovar alloy for brazing. High purity powdered metals of silver, copper, and additives of titanium were used to prepare the active filler alloy, through compacting the mixed powders and alloying in a furnace with argon atmosphere at the temperature of 800oC for 10 minutes. To use it as an active filler metal, it has been modified to a proper thickness. Two groups of alumina were prepared with different sintering temperatures (1450oC and 1650oC) and each group was tested under atmospheric pressure, vacuum furnace pressure of 2*10-4 torr and vacuum furnace pressure of 2*10-6 torr. All the pro

... Show More
View Publication Preview PDF
Publication Date
Sun Mar 01 2020
Journal Name
Agricultural Engineering
Analysis of the Vacuum-Steam Defrosting Process of Plums Pre-Treated with Dehydrofreezing
...Show More Authors
Abstract<p>The research material was prune plums (<italic>Prunus domestica</italic> L.), subjected to osmotic pre-treatment, with variable process time parameters and osmotic solution concentration. Plums thus fixed were frozen and stored for 6 months. At even (monthly) intervals, the product was defrosted by the vacuum-steam method, using the s-p-p chamber, until the thermocouple indicated a temperature of 4ºC in the sample’s thermal center. In order to study the kinetics of phenomena occurring during the defrosting process, the chamber was equipped with a measuring system to enable measurement and recording of temperature changes in time in the geometric center of the sample, as w</p> ... Show More
View Publication
Scopus (1)
Scopus Crossref
Publication Date
Wed Dec 25 2019
Journal Name
Journal Of Engineering
Design of Expert System for Managing the System of AthTharthar Lake
...Show More Authors

The operation and management of water resources projects have direct and significant effects on the optimum use of water. Artificial intelligence techniques are a new tool used to help in making optimized decisions, based on knowledge bases in the planning, implementation, operation and management of projects as well as controlling flowing water quantities to prevent flooding and storage of excess water and use it during drought.

 In this research, an Expert System was designed for operating and managing the system of AthTharthar Lake (ESSTAR). It was applied for all expected conditions of flow, including the cases of   drought, normal flow, and during floods. Moreover, the cases of hypothetical op

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Thu Feb 01 2018
Journal Name
Journal Of Engineering
Using a New Modification on Wind Turbine Ventilator for Improving Indoor Air Quality
...Show More Authors

This paper describes a newly modified wind turbine ventilator that can achieve highly efficient ventilation. The new modification on the conventional wind turbine ventilator system may be achieved by adding a Savonius wind turbine above the conventional turbine to make it work more efficiently and help spinning faster. Three models of the Savonius wind turbine with 2, 3, and 4 blades' semicircular arcs are proposed to be placed above the conventional turbine of wind ventilator to build a hybrid ventilation turbine. A prototype of room model has been constructed and the hybrid turbine is placed on the head of the room roof. Performance's tests for the hybrid turbine with a different number of blades and different values o

... Show More
View Publication Preview PDF
Publication Date
Mon Feb 01 2021
Journal Name
Journal Of Engineering Science And Technology
Air entrained vortex occurrence at sump for inclined multiple intake pipes using cfd
...Show More Authors

Scopus (2)
Scopus
Publication Date
Tue Sep 01 2020
Journal Name
Clinical Plasma Medicine
Breast cancer treatment using cold atmospheric plasma generated by the FE-DBD scheme
...Show More Authors

Background Cold atmospheric plasma (CAP) is widely used in the cancer therapy field. This type of plasma is very close to room temperature. This paper illustrates the effects of CAP on breast cancer tissues both in vivo and in vitro. Methods The mouse mammary adenocarcinoma cell line AN3 was used for the in vivo study, and the MCF7, AMJ13, AMN3, and HBL cell lines were used for the in vitro study. A floating electrode-dielectric barrier discharge (FE-DBD) system was used. The cold plasma produced by the device was tested against breast cancer cells. Results The induced cytotoxicity percentages were 61.7%, 68% and 58.07% for the MCF7, AMN3, and AMJ13 cell lines, respectively, whereas the normal breast tissue HBL cell line exhibited very li

... Show More
View Publication
Scopus (68)
Crossref (54)
Scopus Clarivate Crossref
Publication Date
Mon Feb 04 2019
Journal Name
Iraqi Journal Of Physics
Diagnostics of low-pressure capacitively coupled RF discharge argon plasma
...Show More Authors

Low-pressure capacitively coupled RF discharge Ar plasma has been studied using Langmuir probe. The electron temperature, electron density and Debay length were calculated under different pressures and electrode gap. In this work the RF Langmuir probe is designed using 4MHz filter as compensation circuit and I-V probe characteristic have been investigated. The pressure varied from 0.07 mbar to 0.1 mbar while electrode gap varied from 2-5 cm. The plasma was generated using power supply at 4MHz frequency with power 300 W. The flowmeter is used to control Argon gas flow in the range of 600 standard cubic centimeters per minute (sccm). The electron temperature drops slowly with pressure and it's gradually decreased when expanding the electro