Over the last few decades the mean field approach using selfconsistent
Haretree-Fock (HF) calculations with Skyrme effective
interactions have been found very satisfactory in reproducing
nuclear properties for both stable and unstable nuclei. They are
based on effective energy-density functional, often formulated in
terms of effective density-dependent nucleon–nucleon interactions.
In the present research, the SkM, SkM*, SI, SIII, SIV, T3, SLy4,
Skxs15, Skxs20 and Skxs25 Skyrme parameterizations have been
used within HF method to investigate some static and dynamic
nuclear ground state proprieties of 84-108Mo isotopes. In particular,
the binding energy, proton, neutron, mass and charge densities and
corresponding root mean square radius, neutron skin thickness and
charge form factor are calculated by using this method with the
Skyrme parameterizations mentioned above. The calculated results
are compared with the available experimental data. Calculations
show that the Skyrme–Hartree–Fock (SHF) theory with above
force parameters provides a good description on Mo isotopes.
The present research aims at recognizing the difficulties and problems which hamper teachers and educators alike when using the internet for educational purposes.It discusses the benefits of the internet as a source of information or publication and as a communicative tool.Arandom sample of (30) teachers working at schools in Baghdad / Second Risafa,was selected.Three of the sample members use the internet for student project plans via internet centers, whereas 16 of them use it for chatting, emailing and research purposes.The rest of the sample have limited knowledge of the internet. The researcher used the interviewing method to gather data from
... Show MoreThis paper seeks to study the link between the fundamentalist evidence based on the observance of governance and interests and the ranks of the three legitimate purposes (necessary, need and detailed). The researcher followed the descriptive-analytical approach. The study reached important results, including that the measurement relates to the three ranks, but predominantly attached to measure the meaning of the need and the need, and the measurement of the semi-formal and semi-predominance improvement. Reclamation is considered by the majority of scholars to be authentic if it is related to the necessity and the need, and that it is not acceptable to improve only by a witness who recommends it. The excuses relate to Hajji and Tahini, no
... Show MoreChilled ceilings systems offer potential for overall capital savings. The main aim of the present research is to investigate the thermal performance of the indirect contact closed circuit cooling tower, ICCCCT used with chilled ceiling, to gain a deeper knowledge in this important field of engineering which has been traditionally used in various industrial & HVAC systems. To achieve this study, experimental work were implemented for the ICCCCT use with chilled ceiling. In this study the thermal performances of closed wet cooling tower use with chilled ceiling is experimentally and theoretically investigated. Different experimental tests were conducted by varying the controlling parameters to investigate their effects
... Show MoreIn this research, the dynamics process of charge transfer from the sensitized D35CPDT dye to tin(iv) oxide( ) or titanium dioxide ( ) semiconductors are carried out by using a quantum model for charge transfer. Different chemical solvents Pyridine, 2-Methoxyethanol. Ethanol, Acetonitrile, and Methanol have been used with both systems as polar media surrounded the systems. The rate for charge transfer from photo-excitation D35CPDTdye and injection into the conduction band of or semiconductors vary from a to for system and from a to for the system, depending on the charge transfer parameters strength coupling, free energy, potential of donor and acceptor in the system. The charge transfer rate in D35CPDT / the syst
... Show MoreThirteen isolates were collected from various clinical sources during the periodfrom 22/10/2017 to 22/12/2017. All the isolates were diagnosed based on the microscopic and biochemical propertiesby Vitek-2 Compact system. All isolates formed biofilm 100%, with 30% of isolatesbiofilm produced strongly and 70% on medium. The results of the present study have shown the presence of Curli fimbriae genes in E. cloacae bacteria from cases of urinary tract infections, infected patient with blood bacteremia and inflammation of wounds. Curli fimbriae is considered to be an important factor in the virulence of E.cloacae bacteria, which plays an important role in adhering and combining cells on solid surfaces to form the biofilmand helps in the adhesion
... Show MoreExperimental study has been conducted for laminar natural convection heat transfer of air flow through a rectangular enclosure fitted with vertical partition. The partition was oriented parallel to the two vertical isothermal walls with different temperatures, while all the other surfaces of the enclosure were insulated. In this study a test rig has been designed and constructed to allow studying the effect of Rayleigh number, aperture height ratio, partition thickness, the position of aperture according to the side walls and according to the height, the position of the partition according to the hot wall, and partition inclination. The experiments were carried out with air as the working fluid for Rayleigh number range (5*107 – 1.3*10
... Show MoreIn this work, a vertical pulsating heat pipe heat exchanger (PHPHE) was designed for waste heat recovery, exchanging thermal energy between two air streams in a counterflow configuration. The heat exchanger consists of six rows, each row consists of one pulsating heat pipe (PHP), and each PHP has six turns. The working fluid used in the heat pipe was acetone with fill ratios of 50%, 60%, and 70%. The effect of evaporator inlet temperature at 40, 45, and 50°C and air velocity at 0.5, 0.7, and 0.9 m/s on the pulsating heat pipes consisting of three sections- evaporator, condenser, and adiabatic, whose dimensions were 25 x 25 x 10 cm, was studied. At the same time, the condenser temperature was maintained at 26°C. The system’s th
... Show More