Indoor risk assessment of radon gas in the science college buildings-University of Mustansiriyah using RAD-7 detector
...Show More Authors

In the present work, a set of indoor Radon concentration measurements was carried out in a number of rooms and buildings of Science College in the University of Mustansiriyah for the first time in Iraq using RAD-7 detector which is an active method for short time measuring compared with the passive method in solid state nuclear track detectors (SSNTD's). The results show that, the Radon concentrations values vary from 9.85±1.7 Bq.m-3 to 94.21±34.7 Bq.m-3 with an average value 53.64±26 Bq.m-3 which is lower than the recommended action level 200-300 Bq/m3 [ICRP, 2009].
The values of the annual effective dose (A.E.D) vary from 0.25 mSv/y to 2.38 mSv/y, with an average value 1.46±0.67 mSv/y which is lower than the recommended the range 3-10 mSv/y [ICRP, 1993]. While the values of lung cancer cases per year per million person vary from 4.50 per million person to 42.84 per million person with an average value 24.35±12 per million person which is lower than the recommended range 170-230 per million person [ICRP, 1993].
The values of the potential alpha energy concentration were found to vary from 10.18 mWL to 1.06 mWL, with an average value 5.79±2.8 mWL which is lower than the recommended value of 53.33 mWL given by [UNSCEAR, 1993].

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Dec 11 2021
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Anastrozole Loaded Nanostructured Lipid Carriers : Preparation and Evaluation
...Show More Authors

Anastrozole (ANZ) is considered constitute of the fourth –generation of Non–steroidal aromatase blockage, ANZ has use for hormone receptor positive breast cancer in postmenopausal women. The serious side effects of ANZ including, vaginal dryness, hot flashes, irritability, breast tenderness and un–stability in circulation.

Nanostructured lipid carriers (NLCs) have recently emerged as a multifunctional platform for drug delivery in cancer therapy.

Five formula were composed of (200 mg of glyceryl monostearate, 40 mg of oleic acid , 1% (w/w) Tween 80, 1% (w/w) Poloxamer 407, 1% (w/w) soy lecithin and Vitamin E Polyethylene Glycol Succinate.

The mean particle size, polydispersity index, zeta potential, entrapme

... Show More
View Publication Preview PDF
Scopus (13)
Crossref (6)
Scopus Crossref
Publication Date
Wed Jan 11 2017
Journal Name
Journal: Ibn Al-haitham Journal For Pure And Applied Sciences
Synthesis and Characterization of some Metal Complexes with (3Z ,5Z, 8Z)-2-azido-8-[azido(3Z,5Z)-2-azido-2,6- bis(azidocarbonyl)-8,9-dihydro-2H-1,7-dioxa-3,4,5- triazonine-9-yl]methyl]-9-[(1-azido-1-hydroxy)methyl]-2H1,7-dioxa-3,4,5-triazonine – 2,6 – dicarbonylazide(L-AZ) .
...Show More Authors

The reaction of LAs-Cl8 : [ (2,2- (1-(3,4-bis(carboxylicdichloromethoxy)-5-oxo-2,5- dihydrofuran-2-yl)ethane – 1,2-diyl)bis(2,2-dichloroacetic acid)]with sodium azide in ethanol with drops of distilled water has been investigated . The new product L-AZ :(3Z ,5Z,8Z)-2- azido-8-[azido(3Z,5Z)-2-azido-2,6-bis(azidocarbonyl)-8,9-dihydro-2H-1,7-dioxa-3,4,5- triazonine-9-yl]methyl]-9-[(1-azido-1-hydroxy)methyl]-2H-1,7-dioxa-3,4,5-triazonine – 2,6 – dicarbonylazide was isolated and characterized by elemental analysis (C.H.N) , 1H-NMR , Mass spectrum and Fourier transform infrared spectrophotometer (FT-IR) . The reaction of the L-AZ withM+n: [ ( VO(II) , Cr(III) ,Mn(II) , Co(II) , Ni(II) , Cu(II) , Zn(II) , Cd(II) and Hg(II)] has been i

... Show More
Publication Date
Thu Sep 26 2024
Journal Name
Journal Of Optics
Cysteine-cupped CdSe/CdS quantum dots as an opticalbiosensor for early skin cancer detection
...Show More Authors

This study represents an optical biosensor for early skin cancer detection using cysteine-cupped CdSe/CdS Quantum Dots (QDs). The study optimizes QD synthesis, surface, optical functionalization, and bioconjugation to enhance specificity and sensitivity for early skin cancer cell detection. The research provides insights into QD interactions with skin cancer biomarkers, demonstrating high-contrast, precise cellular imaging. Cysteine-capped CdSe/CdS absorption spectra reveal characteristic peaks for undamaged DNA, while spectral shifts indicate structural changes in skin-cancer-damaged DNA. Additionally, fluorescence spectra show sharp peaks for undamaged DNA and notable shifts and intensity variations when interacting with skin cancer. This

... Show More
View Publication
Clarivate Crossref