Preferred Language
Articles
/
ijp-263
A study of the Zn:Sn mixing ratio effect on the gas detector properties
...Show More Authors

Semiconductor-based metal oxide gas detector of five mixed from zinc chloride Z and tin chloride S salts Z:S ratio 0, 25, 50, 75 and 100% were fabricated on glass substrate by a spray pyrolysis technique. With thickness were about 0.2 ±0.05 μm using water soluble as precursors at a glass substrate temperature 500 ºC±5, 0.05 M, and their gas sensing properties toward CH4, LPG and H2S gas at different concentration (10, 100, 1000 ppm) in air were investigated at room temperature which related with the petroleum refining industry.
Furthermore structural and morphology properties were scrutinize. Results shows that the mixing ratio affect the composition of formative oxides were (ZnO, Zn2SnO4, Zn2SnO4+ZnSnO3, ZnSnO3, SnO2) ratios mentioned in the above respectively, and related with the sensitivity of the reduction tested gases, best sensitivity was for H2S gas, have sensitivity about 80.61% and a response time of 10 seconds for the binary oxides and 89.57% and a response time of (5-2) seconds for the mixed ternary oxides.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Aug 01 2017
Journal Name
Journal Of Multidisciplinary Engineering Science And Technology (jmest)
Study The Influence Of Sn Dopant On The Surface Topography And Some Physical Properties Of CdSe Films Prepared By Evaporation Technique
...Show More Authors

Publication Date
Tue Jan 01 2013
Journal Name
كلية التربية الجامعة المستنصرية
Study the electron drift velocity in gas mixtures of CF3I with N2 obtained from Boltzmann equation analysis
...Show More Authors

Publication Date
Wed Jan 01 2014
Journal Name
كلية التربية -الجامعة المستنصرية
study the electron drift velocity in gas mixtures of SF6 with N2 obtained from Boltzmann equation analysis
...Show More Authors

Publication Date
Sun Jun 01 2014
Journal Name
Baghdad Science Journal
Effect of thickness on optical properties of pure Epoxy Resin plates
...Show More Authors

In this study, Epoxy Resin plates was prepared by mixing epoxy(A) and hardner(B)with ratio(A:B) (3:1) with different thickness (0.3-0.96)cm. The effect of thickness on optical properties have been studied (absorption ,transmission ,reflectance) also the optical constant were found like (absorption coefficient, extenuation coefficient and refraction index) for all of the prepared plates. The results have shown that by increasing the thickness of plates., the absorption intensity increase in which at plates thickness (0.3-0.96)cm the absorption intensity were(1.54-1.43) respectively, and since absorption peak for epoxy occur in ultraviolet region and exactly at wavelength(368)nm and energy gap(Eg=3.05 eV) thus their good transmittance in the

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed May 29 2019
Journal Name
Iraqi Journal Of Physics
Effect of thickness on structural properties of BixSb2-xTe3 thin films
...Show More Authors

BixSb2-xTe3 alloys with different ratios of Bi (x=0, 0.1, 0.3, 0.5, and 2) have been prepared, Thin films of these alloys were prepared using thermal evaporation method under vacuum of 10-5 Torr on glass substrates at room temperature with different deposition rate (0.16, 0.5, 0.83) nm/sec for thickness (100, 300, 500) respectively. The X–ray diffraction measurements for BixSb2-xTe3 bulk and thin films indicate the polycrystalline structure with a strong intensity of peak of plane (015) preferred orientation with additional peaks, (0015) and (1010 ) reflections planes, which is meaning that all films present a very good texture along the (015) plane axis at different intensities for each thin film for different thickness. AFM measureme

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sun Jun 12 2011
Journal Name
Baghdad Science Journal
Effect of additive polyvinyl alcohol polymer on properties of cement – Silica
...Show More Authors

Study the effect of additives polymer polyvinyl alcohol (PVA) after solving in water by concentration 10% since represent a standard of PVA solution with added to cement – silica composite of ratio (1:2) with 5%, 10%, 15%, 20%, and 25% respectively to the standard quantity of water which using as a mortar of building. The results are demonstrate increasing on compression resistance with increase of PVA solution until 20%, and decreasing of thermal conductivity which represent a composite are increasing in thermal insulating. The results were recommended decreasing of water absorption with increase of PVA solution ratio as illustrated in this study.

View Publication Preview PDF
Crossref
Publication Date
Mon Nov 01 2021
Journal Name
Journal Of Engineering
Effect of Fly Ash on Some Properties of Reactive Powder Concrete
...Show More Authors

To achieve sustainability in the field of civil engineering, there has become a great interest in developing reactive powder concrete RPC through the use of environmentally friendly materials to reduce the release of CO2 gas produced from cement factories as well as contribute to the recycling of industrial wastes that have a great impact on environmental pollution.

In this study, reactive powder concrete was prepared using total binder content of 800 kg/m3, water to binder ratio (0.275), and micro steel fibers  1% by volume of concrete. The experimental program included replacing fly ash with (8, 12, 16) % by cement weight to find the optimal ratio, which achieved the best mechanical proper

... Show More
View Publication Preview PDF
Crossref (12)
Crossref
Publication Date
Sat Apr 26 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of systemic administration of Simvastatin on dental implant stability: A random clinical study
...Show More Authors

Background: the primary objective for many researches carried out in dental implantology was to reduce the period needed for functional implant loading, simvastatin (cholesterol lowering medication) had many pleiotropic effects, one of which was increasing bone density around titanium implants (1) and subsequently establishing faster osseointegrated dental implants (2,3). This study aims to reduce the period of time needed to establish secondary stability of dental implant measured in ISQ (Implant Stability Quotient) by investigating the effect of orally administered simvastatin on bone. Materials and methods: simvastatin tablets (40mg/day for three months) were administered orally for 11 healthy women aged (40-51) years old who received 1

... Show More
View Publication Preview PDF
Publication Date
Sun Mar 01 2020
Journal Name
Journal Of Engineering
Effect of Dam Height on The Stability of Earth Dam (Case Study: Karolinka Dam)
...Show More Authors

The Karolinka earth-fill dam was constructed between 1977 and 1984 on the Stanovnice river above the town of Karolinka in the region of Vsetínsko in Czech Republic. Because of leakage on the downstream dam face due to technological indiscipline when filling dam layers during the dam construction stage, there were some steps to improve state dam safety. The final rehabilitation is to construct the diaphragm walls from self-hardening cement-bentonite suspension along the length of the dam. In addition to connecting the gallery and abutment (2 × 25 m long) by using jet piles. The article presents numerical modeling of safety factor evaluation associated with the state of the dam body and foundation; before, and after seal

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Thu Jan 01 2015
Journal Name
Journal Of Engineering
Experimental Study of the effect of closed cavity wall on buildings cooling loads saving
...Show More Authors

The experimental study showed the use of closed cavity wall (the thickness of the cavity 5cm) made a percentage reduction in the cooling load caused by heat gain from the wall by (21.5 %) compared with the conventional wall. also the thermal resistance of the closed cavity was an average (0.2 m2.oC/W).

The experimental results of the study showed that the use of closed cavity wall reduced the average temperature of the inner surface of the wall during the day, and that the reduction was an average (0.45 oC)  when compared with the conventional wall , as well as the use of closed cavity wall reduced the temperature difference range of the inner surface of the wall during the day, and that the

... Show More
View Publication