The main goal of this work is to obtain the plasma electron temperature Te by optical emission spectroscopy of low pressure microwave argon plasma, as a function of working pressure and microwave power. A plasma system was designed and constructed in our laboratory using a magnetron of domestic microwave oven with power 800W without any commercial part. The applied voltage on the magnetron electrical circuit is changed for the purpose of obtaining the variable values of the microwave power. The spectral detection is performed with a spectrometer of wavelength range (200−1000nm). The working pressure and magnetron applied voltage were 0.3-3.0mbar and 180-240V, respectively. Two methods had been applied to estimate the electron temperature, the ratio of two lines’ intensity and Boltzmann plot method. It was found that, for the plasmas investigated, an increase of the electron temperature when the applied voltage has been increasing, while the electron temperature decreases when the working pressure is increasing.
Academic achievement is a professional standard for measuring student levels in the first stages. Therefore, any indication of the level of achievement makes us in an attempt to employ students in evening schools. The researcher has developed a closed questionnaire of (36) paragraphs. A total of (164) male and (24) female students were chosen from evening schools. The result of this research revealed that the number of students was a reason for the low level of their achievement, the lack of laboratories, educational methods, and techniques of the most prominent problems confirmed by students in these schools. In addition, to support educational institutions with their necessary needs. The most important conclusion in this research is th
... Show MoreThe present work intends to study of dc glow discharge were generated between pin (cathode) and a plate (anode) in Ar gas is performed using COMSOL were used to study electric field distribution along the axis of the discharge and also the distribution of electron density and electron temperature at constant pressure (P=.0.0mbar) and inter electrode distance (d=4 cm) at different applied voltage for both pin cathode system and plate anode and comparison with experimental results.
1- The degree of self-control of the educational counselors.
2- The level of work pressures that educational counselors are exposed to from their point of view.
3- The significance of the differences in the degree of self-control and work pressures according to the gender variable (male / female).
4- The relationship between self-control and work stress for the sample as a whole.
The current research was limited to educational counselors of both sexes in Anbar Governorate, Ramadi District, affiliated to the Anbar Education Directorate. The researcher adopted the steps of the relational descriptive approach to achieve the research objectives. The current research community consists of (100) m
... Show MoreHigh intraocular pressure (IOP) is a recognized risk factor for glaucoma and optic nerve injury, and it is one of the primary causes of vision loss globally. Anabasis articulata (AA) is a desert plant found in Iraq. The extract of AA is used to cure diabetes, fever, eczema, and kidney infections. The aim of the study is to evaluate the antioxidant effect of methanol extract of AA on intraocular pressure in the glaucoma rat model. Forty-two rats were allocated into seven groups, each with six animals:: group 1 (normal), group 2 (control), in which animals were induced to have elevated IOP by betamethasone suspension injection, groups 3,4 and 5 for evaluating the effect of 50,100 and 150 mg/kg/day of the tested extract, respective
... Show MoreThe atmospheric air cold plasma has been used to manufacture gold nanomaterials for treating parasitic leishmaniasis. This study experimentally assessed the treatment of Leishmania parasites (L. donovani and L. tropica) by gold nanoparticles. Specifically, atmospheric pressure nonthermal plasma was generated using different diameters (1.0, 2.8, 3.8 and 4.3 mm) of high voltage electrode. Aqueous gold tetrachloride salts (HAuCl4·4H2O) were used as precursor to produce gold nanoparticles. UV-vis spectroscopy and x-ray diffraction were conducted for characterization of the nanoparticles. The optimum condition (a diameter of 1 mm) was chosen to prepare gold nanoparticles, where the grain size was found to be 17 nm. Accordingly, the nanoparticle
... Show MoreInelastic longitudinal electron scattering form factors have been calculated for isoscaler transition
T = 0 of the (0+ ®2+ ) and (0+ ®4+ ) transitions for the 20Ne ,24Mg and 28Si nuclei. Model
space wave function defined by the orbits 1d5 2 ,2s1 2 and 1d3 2 can not give reasonable result for
the form factor. The core-polarization effects are evaluated by adopting the shape of the Tassie-
Model, together with the calculated ground Charge Density Distribution CDD for the low mass 2s-1d
shell nuclei using the occupation number of the states where the sub-shell 2s is included with an
occupation number of protons (a ) .
An Expression for the transition charge density is investigated
where the deformation in nuclear collective modes is taken into
consideration besides the shell model transition density. The
inelastic longitudinal C2 and C4 form factors are calculated using
this transition charge density for the Ne Mg 20 24 , , Si 28 and S 32
nuclei. In this work, the core polarization transition density is
evaluated by adopting the shape of Tassie model togther with the
derived form of the ground state two-body charge density
distributions (2BCDD's). It is noticed that the core polarization
effects which represent the collective modes are essential in
obtaining a remarkable agreement between the calculated inelastic
longi
Background: disturbed physiological rhythm of blood pressure in preeclampsia is a common finding. The role of oxidative stress in pathogenesis of preeclampsia is well accepted. Melatonin is a powerful free radical scavenger so it's rapidly consumed by enhanced reactive oxygen species in preeclampsia causing non-dipping in blood pressure.
Objective: To evaluate the change in plasma melatonin levels in patients with preeclampsia and its relationship with blood pressure.
Patients and methods: In this prospective case control study a total of 40 primigravidae pregnant women were recruited during the period of 11 months between August 2015 and August 2016 in Baghdad teaching hospital, medical city, Iraq, divided into two groups:
Firs