Preferred Language
Articles
/
ijp-259
Spectroscopic measurements of the electron temperature in low pressure microwave 2.45 GHz argon plasma
...Show More Authors

The main goal of this work is to obtain the plasma electron temperature Te by optical emission spectroscopy of low pressure microwave argon plasma, as a function of working pressure and microwave power. A plasma system was designed and constructed in our laboratory using a magnetron of domestic microwave oven with power 800W without any commercial part. The applied voltage on the magnetron electrical circuit is changed for the purpose of obtaining the variable values of the microwave power. The spectral detection is performed with a spectrometer of wavelength range (200−1000nm). The working pressure and magnetron applied voltage were 0.3-3.0mbar and 180-240V, respectively. Two methods had been applied to estimate the electron temperature, the ratio of two lines’ intensity and Boltzmann plot method. It was found that, for the plasmas investigated, an increase of the electron temperature when the applied voltage has been increasing, while the electron temperature decreases when the working pressure is increasing.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Dec 02 2018
Journal Name
Iraqi Journal Of Physics
Optical emission spectroscopy for studying the exploding copper wire plasma parameters in distilled water
...Show More Authors

This work aims to study the exploding copper wire plasma parameters by optical emission spectroscopy. The emission spectra of the copper plasma have been recorded and analyzed The plasma electron temperature (Te), was calculated by Boltzmann plot, and the electron density (ne) calculated by using Stark broadening method for different copper wire diameter (0.18, 0.24 and 0.3 mm) and current
of 75A in distilled water. The hydrogen (Hα line) 656.279 nm was used to calculate the electron density for different wire diameters by Stark broadening. It was found that the electron density ne decrease from 22.4×1016 cm-3 to 17×1016 cm-3 with increasing wire diameter from 0.18 mm to 0.3 mm while the electron temperatures increase from 0.741 to

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Wed Dec 30 2015
Journal Name
Al-kindy College Medical Journal
Precision of pachymetric measurements with Scheimpflug –Placido disc cornealTopography and comparison of these measurements with ultrasonic pachymetry
...Show More Authors

Back ground: Several devices with different physical bases have been developed for the clinical measurement of corneal thickness, they classified into 4 categories: Scheimpflug photography based, Slit –Scanning topography, optical coherence tomography (OCT) based and ultrasound (US) based.Objective:To evaluatethe precision of the new Scheimpflug –Placido disc corneal topography in measurement of corneal thickness and to compare the measured values with that obtained by US pachymetry.Methods: Setting of this study is Lasik center in Eye Specialty Private Hospital. Baghdad. Iraq.Eyes of healthy subjects were examined with the Sirius topography.3 consecutive measurements of central (CCT)and thinnest (TCT) corneal thicknesses were obtain

... Show More
View Publication Preview PDF
Publication Date
Sun Jun 30 2019
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Effect of Microwave Treatment in Graphite Anode for Microbial Fuel Cell and Its Application in Biosensor
...Show More Authors

The electrode in the microbial fuel cell has a significant effect on cell performance. The treatment of the electrode is a crucial step to make the electrode surface more habitable for bacteria growth, thus, increases the power production as well as waste treatment. In the current study, two graphite electrodes were treated by a microwave. The first electrode was treated with 100W microwave energy, while the second one was treated with 600W microwave energy. There is a significant enhancement in the surface of the graphite anode after the pretreatment process. The results show an increase in the power density from 10 mW/m2 to 15 mW/m2 with 100w treatment and to 13.47 mW/m2 with 600w treatment. An organic

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Sun Apr 01 2018
Journal Name
Iraqi Journal Of Science
Estimation of The Zenith Path Delay using RTK-DGPS measurements
...Show More Authors

In this paper, the method of estimating the variation of Zenith Path Delay (ZPD) estimation method will be illustrate and evaluate using Real Time Kinematic Differential Global Positioning System (RTK-DGPS). The GPS provides a relative method to remotely sense atmospheric water vapor in any weather condition. The GPS signal delay in the atmosphere can be expressed as ZPD. In order to evaluate the results, four points had been chosen in the university of Baghdad campus to be rover ones, with a fixed Base point. For each rover position a 155 day of coordinates measurements was collected to overcome the results. Many models and mathematic calculations were used to extract the ZPD using the Matlab environment. The result shows that the ZPD valu

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Tue Dec 01 2020
Journal Name
Journal Of Engineering Science And Technology
Survey and discharge measurements of the Iraqi border crossing rivers
...Show More Authors

Scopus (1)
Scopus
Publication Date
Sun Apr 29 2018
Journal Name
Iraqi Journal Of Science
Estimation of The Zenith Path Delay using RTK-DGPS measurements
...Show More Authors

In this paper, the method of estimating the variation of  Zenith Path Delay (ZPD) estimation method will be illustrate and evaluate using Real Time Kinematic Differential Global Positioning System (RTK-DGPS). The GPS provides a relative method to remotely sense atmospheric water vapor in any weather condition. The GPS signal delay in the atmosphere can be expressed as ZPD. In order to evaluate the results, four points had been chosen in the university of Baghdad campus to be rover ones, with a fixed Base point. For each rover position a 155 day of coordinates measurements was collected to overcome the results. Many models and mathematic calculations were used to extract the ZPD using the Matlab environment. The result shows

... Show More
View Publication Preview PDF
Publication Date
Tue Oct 20 2020
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Theoretical Study of the Photons Production Kinetic In Hot Quark-Gluon Plasma Matter
...Show More Authors

In this paper, we study flow of photons rate production in a quark-gluon QG plasma. General theory of this study is based on the field theory for hard interaction. The kinetic of photons production from hard interaction in charm with anti-top to production photons with gluon due to plasma phase at high temperatures (150, 200,250,300 and 350 MeV) .It has been investigated and studied using the postulate of quantum chromodynamic theory QCD .The photons production rate of hard photons with( GeV) are insensitive to strength coupling and depend mainly on the temperature of system T . Despite the different critical temperature (150 and 190MeV) comes, we find that same order of flow rate photons magnitude in both cases. In both cases, the f

... Show More
View Publication Preview PDF
Crossref (6)
Crossref
Publication Date
Wed Jun 01 2022
Journal Name
Political Sciences Journal
The The US Pressure and Sanctions Policy in Changing Iran's Conduct
...Show More Authors

This research aims to analyze the impact of the United States policy of pressure and sanctions on changing Iran's conduct. Since the Islamic Revolution of Iran in 1979, the US has continuously pursued various policies towards Iran, aiming to change the regime by force or isolate it politically and economically. The main research question lies in the following: To what extent does the US pressure policy and its sanctions affect the conduct Iran?. This research discusses that the more there are economic and political alternatives to Iran, the more it will be challenging the US demands. Moreover, the more the US pursues a negotiating policy based on mutual interests, the more Iran will positively respond to American demands.

View Publication Preview PDF
Crossref
Publication Date
Sun Dec 05 2021
Journal Name
Iraqi Journal Of Science
The Effect of the Non-Thermal Plasma Needle on Pseudomonas Aeruginosa Bacteria
...Show More Authors

The development in the field of medical physics has led to the use of devices that
are manufactured under normal conditions to make tremendous progress in the
world of development in medical treatment by using these devices with modern
techniques by reducing the use of antibiotics and relying on these tools and devices
that link between physics and modern therapeutic medicine. In this research, a nonthermal
plasma system for argon gas operated at normal atmospheric pressure was
designed, this system was applied on Pseudomonas Aeruginosa bacteria isolated
from burn patients from Yarmouk Teaching Hospital. These bacteria were exposed
to this system, the results showed that these bacteria were killed at time (5 min)

... Show More
View Publication Preview PDF
Publication Date
Mon Feb 25 2019
Journal Name
Iraqi Journal Of Physics
Influence of electrodes area ratios and the discharge volume in RF capacitively coupled plasma
...Show More Authors

Experimental results on harmonic distortions in 13.56 MHz RF Argon glow discharge using different grounded electrodes areas and electrodes spacing are presented. The experiment is carried out at four pressure values. RF power values used are between 20 and 90 watts. The results indicate significant increase in distortions at two specific values of the cone angle enclosing the two electrodes within its geometrical volume. The computation of the cone head angle gave the symmetry discharge or asymmetry as well as when the angle is small the condition is near symmetry discharge associated with decrease in the nonlinearity.

View Publication Preview PDF
Crossref