Radiation measuring devices need to process calibration which
lose their sensitivity and the extent of the response and the amount of
stability under a changing conditions from time to time and this
period depends on the nature and use of field in which used devices.
A comparison study was done to a (451P) (ionization chamber
survey meter) and this showed the variation of calibration factor in
five different years. This study also displayed the concept of
radiation instrument calibration and necessity of every year
calibration of them.
In this project we used the five years calibration data for ionization
chamber survey meter model Inspector (451P) to get that the values
of Calibration Factor (CF) and Response (1/CF). The value deviation
(Δ%) of CFs for four years of calibration in comparison of CF for the
year 2007 are very high and the device under research is not good to
use in field and reliable because the ionization chamber is very
sensitive to humidity and must calibrate a year or less, or during
every two years and must maintain carefully to reduce the discarded
effects to the measurements.
This study has been undertaken to postulate the mechanism of impact test at low velocities. Thin-walled tubes of 100Cr6 were deformed under axial compression. In the present work there are seven velocities (4.429,4.652,5.240,5.600,5.942,6.264, 6.569) m\sec were applied to show how they effect the load, change in length, also the kinetic energy. However, the comparison between the obtained results and the other studies (Alexandar[3] , Abramowicz[4], Ayad[5]) was made the present work and Ayad data show good agreement. Load, change in length, kinetic energy were determined to understand the impact test.
The interest in calcium phosphates arises from the fact that bones contain a high percentage of mineralized calcium phosphate . In this study, pure and biocompatible hydroxyapatite (HAP) powder was successfully synthesized using hen’s egg shell as calcium source and phosphoric acid by precipitation method.The precipitate obtained was subjected to ripenning process for 24 hours, filtered, air dried, and calcined at temperatures of 400,800,900,and 1000 ºC.
X-Ray diffraction(XRD) technique was used to investigate the formation of HAP powder, XRD results revealed the HAP formation and also indicate no occurrence of secondary phases. Fourier Transform Infrared(FT-IR) spectrum shows the characterstic peaks for phosphate and hydroxyl grou
Been Antkhav three isolates of soil classified as follows: Bacillus G3 consists of spores, G12, G27 led Pal NTG treatment to kill part of the cells of the three isolates varying degrees treatment also led to mutations urged resistance to streptomycin and rifampicin and double mutations
Anaemia is one of the most important problems of malnutrition in the world, especially in countries developing and anemia is associated inextricably important public health and HIV and morbidity and reduced mental capacity This study aims to determine the incidence of anemia for the period 1999-2000 among healthy adults outwardly and its relationship with some variablesjob related study sample included 200 male and 200 Antymn but the cities of Baghdad and Baquba reviewers for central labs
Studied the optical properties of the membranes CdS thin containing different ratios of ions cadmium to sulfur attended models manner spraying chemical gases on the rules of the glass temperature preparation (350c) were calculated energy gap allowed direct these membranes as observed decrease in the value of the energy gap at reducing the proportion ofsulfur ions as absorption coefficient was calculated
One hundred thirty - five clinical specimens of urine, blood, teeth root canal and burns were obtained from patients in hospitals of Baghdad. The specimens were cultured on Pfizer Selective Enterococcus agar to purify Enterococci isolates. 20 E. faecalis isolates were identified biochemically by growing in 10Cº, 45Cº, 6.5% NaCl, at pH 9.6 and confirmed by VITEK. Determination of Vancomycin-Resistant E. faecalis isolates were done by the minimum inhibitory concentrations [MICs] using agar dilution method. Seventeen E. faecalis isolates were determined as Vancomycin-Resistant and Intermediate Resistant.
This study aims to investigate the behavior and strength of self-compacted ferrocement slabs under punching shear load. Experimental results of thirteen square ferrocement slabs of 500×500 mm simply supported on all edges are presented. The main parameters investigated include the volume fraction of reinforcement, slab thickness and size of load-bearing plate. The load deflection and cracking characteristics of the tested slabs are studied and compared. The test results showed that the volume fraction of wire mesh has significant effect on both ultimate load and displacement. The increase of slab thickness leads to decrease in deflection values and increase in stiffness of slabs. Both ductility and stiffness increase as the
... Show MoreVarious Hall Effects have been successfully observed in samples of n-type indium antimonide with values for conductivity, energy gap, Hall mobility and Hall coefficient all agreeing with theory. A particular interest in developing a method for obtaining accurate values of carrier concentrations in semiconductor samples has been fulfilled with an experimental result of (1.6×1016 cm-3 ±10.7%) giving a percentage difference of (6.7%) to a quoted value of (1.5×1016cm-3) at (77K) using an (80mW C.W. CO2) laser beam at (10.6μm) to illuminate a similar sample of n-type indium antimonide, an "Optical" Hall effect has been observed. Although some doubt has been raised as to the validity of effect i.e. "thermal" rather than "Optical", values o
... Show MoreIn this paper, the fundamental harmonic of a Nd:YAG laser (Q-switched 1064nm wavelength, 1 Hz repetition rate and 9 ns pulse duration) has been used for the ablation of cadmium samples in air at atmospheric pressure and the generation of the cadmium plasma. The experimentally observed lines of cadmium plasma emission have been used to calculate the plasma parameters such as (electron temperature (TReR), electron density (nReR), Debye length (λRDR) and plasma frequency (ωRpR)). Line pair ratio of neutral species have been used for the electron temperature and electron density measurements. Plasma parameters were studied as a functions of laser pulse energy.