Preferred Language
Articles
/
ijp-233
Determination of some characteristics of comet’s gases by photometry method for comet Hyakutake
...Show More Authors

The present paper focuses on the study of some characteristics of
comets ions by photometry method which represent by CCD camera
which it provide seeing these images in a graded light. From 0-255
when Zero (low a light intensity) and 255 (highlight intensity). These
differences of photonic intensity can be giving us a curve which
appear from any line of this image.
From these equations the focus is concentrating on determine the
temperature distribution, velocity distribution, and intensity number
distribution which is give number of particles per unit volume.
The results explained the interaction near the cometary nucleus
which is mainly affected by the new ions added to the density of the
solar wind, the average molecular weight increase and result in many
unique characteristics of the cometary tail.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Apr 30 2018
Journal Name
Journal Of Materials Science: Materials In Electronics
H2S gas sensitivity of PAni nano fibers synthesized by hydrothermal method
...Show More Authors

In this work, PAni nanofibers (NFs) are successfully synthesized via hydrothermal method. The structural, surface morphological, optical, electrical and H2S gas sensing properties have been investigated for PAni thin films deposited by spin coating technique. The XRD pattern reveals crystalline nature of PAni NFs with crystallite size of 9.2 nm. The SEM image of Polyaniline clearly indicates that the polymer possesses nanofiber like structure. The optical properties show that the optical energy gap follows allowed direct electronic transition calculated using Tauc’s equation. Intense hotoluminescence (PL) peaks at 309, 340 and 605 nm are observed. The electrical properties such as D.C. conductivity and Hall effect have been studied wher

... Show More
Publication Date
Sat Jul 22 2023
Journal Name
Journal Of Engineering
Removal of Boron from Simulated Iraqi Surface Water by Electrocoagulation Method
...Show More Authors

The removal of boron from aqueous solution was carried out by electrocoagulation (EC) using magnesium electrodes as anode and stainless steel electrodes as cathode. Several operating parameters on the removal efficiency of boron were investigated, such as initial pH, current density, initial boron ion concentration, NaCl concentration, spacing between electrodes, electrode material, and presence of carbonate concentration. The optimum removal efficiency of 91. 5 % was achieved at a current density of 3 mA/cm² and  pH = 7 using (Mg/St. St. ) electrodes, within 45 min of operating time. The concentration of NaCl was o. 1 g/l with a 0.5cm spacing between the electrodes. First and second order rate equation were applied to study adsorp

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Jun 01 2021
Journal Name
International Journal Of Nanoscience
Synthesis and Spectroscopic Characterization of Platinum Nanoparticles by Plasma Jet Method
...Show More Authors

In this research, Argon gas was used to generate atmospheric plasma in the manufacture of platinum nanomaterials, to study the resultant plasma spectrum and to calculate the cellular toxicity of those manufactured nanomaterials. This research is keen on the generation of nonthermal atmospheric pressure plasma using aqueous platinum salts (H2PtCl6 6H2O) with different concentrations and exposure of cold plasma with a different time period used to produce platinum nanoparticles, to ensure typical preparation of nanoparticles. Visible UV and X-rays were performed for this purpose, and the diameter of the system probe was (1[Formula: see text]mm) with the Argon gas flow of

... Show More
View Publication
Scopus (10)
Crossref (7)
Scopus Clarivate Crossref
Publication Date
Fri Oct 14 2022
Journal Name
Diagnostics
Determination of the Accuracy of Salivary Biomarkers for Periodontal Diagnosis
...Show More Authors

Background: We aimed to investigate the accuracy of salivary matrix metalloproteinases (MMP)-8 and -9, and tissue inhibitor of metalloproteinase (TIMP)-1 in diagnosing periodontitis and in distinguishing periodontitis stages (S)1 to S3. Methods: This study was a case–control study that included patients with periodontitis S1 to S3 and subjects with healthy periodontia (controls). Saliva was collected, and then, clinical parameters were recorded, including plaque index, bleeding on probing, probing pocket depth, and clinical attachment level. Diagnosis was confirmed by assessing the alveolar bone level using radiography. Salivary biomarkers were assayed using an enzyme-linked immunosorbent assay. Results: A total of 45 patients (15

... Show More
View Publication
Scopus (36)
Crossref (39)
Scopus Clarivate Crossref
Publication Date
Wed Dec 01 2021
Journal Name
International Journal Of Agricultural And Statistical Sciences
ESTIMATING NONPARAMETRIC AUTOREGRESSIVE CURVE BY SMOOTHING SPLINES METHOD
...Show More Authors

Preview PDF
Scopus
Publication Date
Wed Jan 01 2020
Journal Name
Advances In Intelligent Systems And Computing
Forecasting by Using the Optimal Time Series Method
...Show More Authors

View Publication
Scopus (20)
Crossref (10)
Scopus Crossref
Publication Date
Sun Jan 03 2016
Journal Name
Journal Of The College Of Basic Education
Simultaneous determination of cephalexin and cefixime by first and second derivative ultraviolet spectrophotometry
...Show More Authors

Publication Date
Fri Jan 01 2016
Journal Name
Journal Of The College Of Basic Education
Simultaneous Determination of Cephalexin and Cefixime by First and Second Derivative Ultraviolet Spectrophotometry
...Show More Authors

A new spectrophotometric method for individual and simultaneous determination of cefixime and cephalexin depending on the first and second derivative mode techniques. The first and second derivative spectra of these compounds permitted individual and simultaneous determination of cefixime and cephalexin in concentration interval of (4– 24μg.ml-1 ) by measuring the amplitude of peak-to-base line, pea to peak at certain wavelengths and the area under peak at selected spectrum intervals. The methods showed reasonable precision and accuracy and have been applied to determine cefixime and cephalexin in two different pharmaceutical preparations.

Publication Date
Sat Dec 15 2018
Journal Name
Revista De Chimie
Determination of Ethanol in Fermented Broth by Headspace Gas Chromatography using Capillary Column
...Show More Authors

The gas chromatography (GC) method in analytical chemistry is a quick and accurate method to detect volatile components like ethanol. A method for determining volatile components known as Headspace chromatography (HS-GC) was developed along with an internal standard method (ISM) to identify ethanol in fermented broth in the laboratory. The aim of this research is determining the concentration of ethanol in fermented broth using capillary column (ZB-1). This method can analyze ethanol concentrations in the fermented medium broth ranging from 10 to 200 g/L. The validation of this method was done in order to obtain the results to be of high precision and the significant, precision was represented as the relative standard deviation (RSD) which

... Show More
Crossref (4)
Crossref
Publication Date
Mon Feb 01 2010
Journal Name
Food Chemistry
Determination of aflatoxins in animal feeds by HPLC with multifunctional column clean-up
...Show More Authors

A reversed-phase HPLC method with fluorescence detection for the determination of the aflatoxins B1, B2, G1 and G2 in 42 animal feeds, comprising corn (16), soya bean meal (8), mixed meal (13), sunflower, wheat, canola, palm kernel, copra meals (1 each) was carried out. The samples were first extracted using acetonitrile:water (9:1), and was further cleaned-up using a multifunctional column. Optimum conditions for the extraction and chromatographic separation were investigated. By adopting an isocratic chromatographic system using a mobile phase comprising acetonitrile:methanol:water (8:27:65, v/v/v), the separation of the four aflatoxins was possible within 30 min. Recoveries for aflatoxins B1, B2, G1 and G2 were 98 ± 0.7%, 95 ± 1.0%, 94

... Show More
View Publication
Scopus (122)
Crossref (108)
Scopus Clarivate Crossref