To assess the contribution of Doppler broadening and examine the
Compton profile, the Compton energy absorption cross sections are
measured and calculated using formulas based on a relativistic
impulse approximation. The Compton energy-absorption cross
sections are evaluated for different elements (Fe, Zn, Ag, Au and Hg)
and for a photon energy range (1 - 100 keV). With using these crosssections,
the Compton component of the mass–energy absorption
coefficient was derived, where the electron momentum prior to the
scattering event caused a Doppler broadening of the Compton line.
Also, the momentum resolution function was evaluated in terms of
incident and scattered photon energy and scattering angle. The results
of cross sections for the coherent and incoherent processes are
compared with theoretical values and reported values of other
researchers. The present results are in agreement with the theoretical
values.
New simple and sensitive spectrophotometric methods for the determination of paracetamol in aqueous medium were developed. The first method is based on coupling of paracetamol with p-amino-2-hydroxy sodium benzoate (AHB) in the presence of sodium periodate, as oxidizing agent, to form a brownish-orange compound which shows a λmax at 470 nm. The molar absorptivity (εmax) of the colored product was found to be (3371) l. mole1. cm-1 and Sandel’s index 0.0449 μg. cm-2. The method follows Beer’s law in the concentration range of 12.5-500.0 μg of paracetamol in a final volume of 25 ml (0.5-20.0) μg. ml-1 with relative standard deviation percent (RSD%) ranged between 0.26-4.71% and accuracy, expressed by recovery percent, 95-106% for five
... Show MoreA spectrophotometric- reverse flow injection analysis (rFIA) method has been proposed for the determination of Nitrazepam (NIT) in pure and pharmaceutical preparations. The method is based upon the coupling reaction of NIT with a new reagent O-Coumaric acid (OCA) in the presence of sodium periodate in an aqueous solution. The blue color product was measured at 632 nm. The variation (chemical and physical parameters) related with reverse flow system were estimated. The linearity was over the range 15 - 450 µg/mL of NIT with detection limits and limit of quantification of 3.425 and 11.417 µg mL-1 NIT,respectively. The sample throughput of 28 samples
... Show MoreBackground: Accurate detection of thyroid autoantibodies by enzyme linked immunosorbant assay technique namely thyroglobulin antibody, thyroid peroxides antibody is crucial in the differentiation of autoimmune thyroid disorders from other form of thyroid diseases.
Objective: Evaluation of the detection of thyroglobulin antibody and thyroid peroxides antibody in different thyroid diseases using enzyme linked immunosorbant assay technique.
Methods: - Seventy-five patients admitted to Surgical Units of Baghdad Medical City Hospital for the period between "October 2010 to June 2011" they were waiting to do thyroidectomy. They were chosen nonselectively for serological evaluation of above autoantibodies , and correlation of the results
The effect of ethanol and methanol solvent, and their mixture has been studied on the absorption and fluorescence spectra of laser dye Rhodamine B at concentration of (10-4) Molar at room temperature. The molar absorption coefficient has been determined for mixture which was (3.223) at wave number (18181.8 cm-1), Also the Quantum Efficiency of the two solvents (ethanol and methanol) and their mixture have been calculated ,which was for mixture spectrum (38.94%) and it was larger comparing with other and solvents. The characteristics of spectrum has been determined by calculating (??) of absorption spectrum for the solvents and its mixture at maximum wave number ( ) cm-1 depending on solvent polarity and the transitions between molecular ene
... Show MoreA sensitive and accurate colorimetric method was developed for the determination of the Sitagliptin phosphate monohydrate, here and after will be named Sitagliptin, in its pure and pharmaceutical form. The suggested approach is based on boosting the sensitivity of the traditional spectrometric methods by derivatizing Sitagliptin into a colored product that absorbs the visible spectrum at 573 nm. The proposed method has effectively improved the sensitivity and the limit of detection for the analysis of Sitagliptin. A linear calibration curve was obtained over the concentration range of 0.1-10 μg/ml with a correlation coefficient of 0.9983. The calculated recovery was within the range of 98.98–100.11%. While the limit of detection LOD and
... Show MoreSecurity reflects a permanent and complex movement that complies with international and societal needs and developments in all its dimensions, interactions and levels. To constitute a universal demand for all States, communities and individuals. The question of security is one of the most important motivations and motivations that govern the behavior, and even the objectives of those societies and States. These groups or individuals have always sought to avoid fear and harm, and to provide stability, safety and security. In the light of this, security studies have been among the important fields of study in the field of international and strategic relations. The field witnessed many theoretical efforts, from the traditional perspective,
... Show MoreAt the beginning of the twentieth century distorting handling totalitarian phenomena of art, which can be called the stage of the test, transition from the theory of ideal theory and other realistic is not cushy, since it requires vision and reading and other concepts, and in light of this dialectic manifested research problem by asking the following Is affected by the design idealism and realism. Through the above mentioned questions, the researcher found rationale for addressing this problem, the study through his research, which is marked (idealism and realism in a comparative study design). And demonstrated the importance of research in the identification of the concept and the effectiveness of the two theories idealism and realism a
... Show More