Non-thermal argon plasma needle at atmospheric pressure was
constructed. The experimental setup was based on a simple and low
cost electric component that generates a sufficiently high electric
field at the electrodes to ionize the argon gas which flow at
atmospheric pressure. A high AC power supply was used with 1.1
kV and 19.57 kHz. Non-thermal Argon plasma used on blood
samples to show the ability of non-thermal plasma to promote blood
coagulation. Three tests have been done to show the ability of plasma
to coagulate both normal and anti-coagulant blood. Each blood
sample has been treated for varying time from 20sec. to 180sec. at
different distances. The results of the current study showed that the
cold plasma produced from argon significantly increase the in vitro
speed of blood coagulation, the plasma increases activation and
aggregation of platelets, causes proliferation of fibroblasts and fibrin
production accelerates blood coagulation.
RM Abbas, AA Abdulhameed, AI Salahaldin, International Conference on Geotechnical Engineering, 2010
In the last years, the self-balancing platform has become one of the most common candidates to use in many applications such as flight, biomedical fields, industry. This paper introduced the simulated model of a proposed self-balancing platform that described the self–balancing attitude in (X-axis, Y-axis, or both axis) under the influence of road disturbance. To simulate the self-balanced platform's performance during the tilt, an integration between Solidworks, Simscape, and Simulink toolboxes in MATLAB was used. The platform's dynamic model was drawn in SolidWorks and exported as a STEP file used in the Simscape Multibody environment. The system is controlled using the proportional-integral-deriva
... Show MoreThis book presents the problem of tooth decay due to bacteria Streptococcus mutans one of methods of treatment using 3 extracts of S. persica (miswak) (aqueous, acetone and methanol) and prove its effectiveness and its impact on the gtf (B, C, and D) genes that code the glucosyltransferase (Gtf) enzymes that cause decay membrane compared to the usual means used for the prevention of tooth decay
This study uses the performance of the discretionary estimation models by using a sample of listed companies in the Netherlands and Germany. The actual accounting framework provides a wide opportunity for managers to influence data in financial reporting. The corporate reporting strategy, the way managers use their discretionary accounting, has a significant effect on the company's financial reporting. The authors contribute to the literature through enhancement to these models to accomplish better effects of identifying earnings management as well as to present evidence that is particular to the Dutch and German setting.
For this, we followed the methodology of Dechow, Sloan, and Sweeney (1995) and Chan
... Show MoreIrisin is a myokine that controls energy metabolism by making adipose tissue brown. The present goal in doing this research was to determine how irisin concentration relates to other biochemical markers of disease. Hemodialysis (HD) for chronic kidney failure. The study included 30 individuals with end-stage renal disease on HD and 30 healthy subjects as the control group. The ages of all patients and the control group ranged from (25 to 60) years. The excluded criteria included patients with viral hepatitis and diabetes. Serum irisin concentration and the level of fasting serum glucose (FSG), urea, creatinine (Cr), total protein (TP), albumin (Alb), albumin to creatinine ratio (ACR), total cholesterol (TC), alanine aminotransferase (ALT),
... Show MoreThis paper studies the effects of stiffeners on shear lag in steel box girders with stiffened flanges. A three-dimensional linear finite element analysis using STAAD.Pro V8i program has been employed to evaluate and determine the actual top flange stress distribution and effective width in steel box girders. The steel plates of the flanges and webs have been modeled by four-node isoparametric shell elements, while the stiffeners have been modeled as beam elements. Different numbers (4, 8, and 15) for the steel stiffeners have been used in this study to establish their effects on the shear lag and longitudinal stresses in the flange. Using stiffeners reduced the magnitude of the top flange longitudinal stresses about 40%, but did
... Show More